Loss Analysis and Calculation for Three-level IGBT Inverter

Taking three-level converter application as an example, this paper analysed the components and influence factors of heat loss of working IGBT, presented an approach to calculate the heat loss of IGBT in three-level converter by different control methods, used the simulation or testing data as input...

Full description

Saved in:
Bibliographic Details
Main Authors: ZHU Wu, XIN Li, LI Yanyong, ZHANG Donghui
Format: Article
Language:zho
Published: Editorial Office of Control and Information Technology 2017-01-01
Series:Kongzhi Yu Xinxi Jishu
Subjects:
Online Access:http://ctet.csrzic.com/thesisDetails#10.13889/j.issn.2095-3631.2017.05.015
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Taking three-level converter application as an example, this paper analysed the components and influence factors of heat loss of working IGBT, presented an approach to calculate the heat loss of IGBT in three-level converter by different control methods, used the simulation or testing data as input to obtain heat losses of each IGBT in a three-level topology converter, and obtained a result whose error is within 2%. Furthermore, this approach can also be applied to the product design on early stage for precise computation of heat losses. With this approach, it is more likely to choose a reasonable cooling system which can guarantee that junction temperature is below permitted values and a rational redundant capacity of cooling system at the same time. Precise calculation of heat losses of the system with other power devices may refer to this paper as well.