Management of Neglected Floating Knee with Rotational Deformity and Limb Shortening Using the Ortho-SUV Frame: A Case Report

Floating Knee Injury (FKI) are associated with significant complications, including deformity and limb shortening. The Ortho-Solomin-Utekhin-Vilensky (SUV) (OSF) system, integrated with computer software for precision correction, offers an effective solution for treating complex cases, particularly...

Full description

Saved in:
Bibliographic Details
Main Authors: Vishal S Patil, Mohammed Talha Muneer, Archit Gupta, Raj Kamble
Format: Article
Language:English
Published: JCDR Research and Publications Private Limited 2025-01-01
Series:Journal of Clinical and Diagnostic Research
Subjects:
Online Access:https://www.jcdr.net/articles/PDF/20449/74605_CE[Ra1]_F(SHU)_QC(SD_IS)_PF1(RI_SS)_PFA(NC)_PN(IS).pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841554670161494016
author Vishal S Patil
Mohammed Talha Muneer
Archit Gupta
Raj Kamble
author_facet Vishal S Patil
Mohammed Talha Muneer
Archit Gupta
Raj Kamble
author_sort Vishal S Patil
collection DOAJ
description Floating Knee Injury (FKI) are associated with significant complications, including deformity and limb shortening. The Ortho-Solomin-Utekhin-Vilensky (SUV) (OSF) system, integrated with computer software for precision correction, offers an effective solution for treating complex cases, particularly those with rotational deformities. Hereby the authors present the case of a 38-year-old male who sustained a floating knee injury following a high-velocity Road Traffic Accident (RTA). Initial management included stabilisation with an external fixator following Damage Control Orthopaedic (DCO) principles. However, the patient was lost to follow-up and presented three months later with a neglected flexion deformity and significant external rotation of the knee. Clinical and radiological findings showed malunion, knee deformity and a limb length discrepancy of 2 cm. The external fixator was removed and deformity correction and limb lengthening were planned using the OSF frame, a hexapod system designed for complex deformity corrections. Intraoperative findings revealed full-thickness quadriceps muscle loss. The OSF system was used to correct rotational deformities and induce limb lengthening through corticotomy and distraction osteogenesis over a three-month period. Radiological assessments confirmed new bone formation, although residual proximal tibia displacement required screw fixation. After six weeks of non weight bearing, the patient achieved full weight-bearing with normal range of motion. The present case highlights the utility of the OSF system in achieving deformity correction and limb lengthening, demonstrating satisfactory functional outcomes in a neglected floating knee injury. The case underscores the importance of timely follow-up and the role of advanced external fixation techniques in managing complicated orthopaedic injuries.
format Article
id doaj-art-e189098614cb434cbd359c8b14b575de
institution Kabale University
issn 2249-782X
0973-709X
language English
publishDate 2025-01-01
publisher JCDR Research and Publications Private Limited
record_format Article
series Journal of Clinical and Diagnostic Research
spelling doaj-art-e189098614cb434cbd359c8b14b575de2025-01-08T12:19:46ZengJCDR Research and Publications Private LimitedJournal of Clinical and Diagnostic Research2249-782X0973-709X2025-01-011901010410.7860/JCDR/2025/74605.20449Management of Neglected Floating Knee with Rotational Deformity and Limb Shortening Using the Ortho-SUV Frame: A Case ReportVishal S Patil0Mohammed Talha Muneer1Archit Gupta2Raj Kamble3Professor, Department of Orthopaedics, Dr. D. Y. Patil Medical College, Hospital and Research Centre, Pune, Maharashtra, India.Resident, Department of Orthopaedics, Dr. D. Y. Patil Medical College, Hospital and Research Centre, Pune, Maharashtra, India.Resident, Department of Orthopaedics, Dr. D. Y. Patil Medical College, Hospital and Research Centre, Pune, Maharashtra, IndiaResident, Department of Orthopaedics, Dr. D. Y. Patil Medical College, Hospital and Research Centre, Pune, Maharashtra, IndiaFloating Knee Injury (FKI) are associated with significant complications, including deformity and limb shortening. The Ortho-Solomin-Utekhin-Vilensky (SUV) (OSF) system, integrated with computer software for precision correction, offers an effective solution for treating complex cases, particularly those with rotational deformities. Hereby the authors present the case of a 38-year-old male who sustained a floating knee injury following a high-velocity Road Traffic Accident (RTA). Initial management included stabilisation with an external fixator following Damage Control Orthopaedic (DCO) principles. However, the patient was lost to follow-up and presented three months later with a neglected flexion deformity and significant external rotation of the knee. Clinical and radiological findings showed malunion, knee deformity and a limb length discrepancy of 2 cm. The external fixator was removed and deformity correction and limb lengthening were planned using the OSF frame, a hexapod system designed for complex deformity corrections. Intraoperative findings revealed full-thickness quadriceps muscle loss. The OSF system was used to correct rotational deformities and induce limb lengthening through corticotomy and distraction osteogenesis over a three-month period. Radiological assessments confirmed new bone formation, although residual proximal tibia displacement required screw fixation. After six weeks of non weight bearing, the patient achieved full weight-bearing with normal range of motion. The present case highlights the utility of the OSF system in achieving deformity correction and limb lengthening, demonstrating satisfactory functional outcomes in a neglected floating knee injury. The case underscores the importance of timely follow-up and the role of advanced external fixation techniques in managing complicated orthopaedic injuries.https://www.jcdr.net/articles/PDF/20449/74605_CE[Ra1]_F(SHU)_QC(SD_IS)_PF1(RI_SS)_PFA(NC)_PN(IS).pdfbone lengtheningcomputer-assisted external fixatorsfracture fixationknee injuriesmalunionortho-solomin-utekhin-vilensk frame
spellingShingle Vishal S Patil
Mohammed Talha Muneer
Archit Gupta
Raj Kamble
Management of Neglected Floating Knee with Rotational Deformity and Limb Shortening Using the Ortho-SUV Frame: A Case Report
Journal of Clinical and Diagnostic Research
bone lengthening
computer-assisted external fixators
fracture fixation
knee injuries
malunion
ortho-solomin-utekhin-vilensk frame
title Management of Neglected Floating Knee with Rotational Deformity and Limb Shortening Using the Ortho-SUV Frame: A Case Report
title_full Management of Neglected Floating Knee with Rotational Deformity and Limb Shortening Using the Ortho-SUV Frame: A Case Report
title_fullStr Management of Neglected Floating Knee with Rotational Deformity and Limb Shortening Using the Ortho-SUV Frame: A Case Report
title_full_unstemmed Management of Neglected Floating Knee with Rotational Deformity and Limb Shortening Using the Ortho-SUV Frame: A Case Report
title_short Management of Neglected Floating Knee with Rotational Deformity and Limb Shortening Using the Ortho-SUV Frame: A Case Report
title_sort management of neglected floating knee with rotational deformity and limb shortening using the ortho suv frame a case report
topic bone lengthening
computer-assisted external fixators
fracture fixation
knee injuries
malunion
ortho-solomin-utekhin-vilensk frame
url https://www.jcdr.net/articles/PDF/20449/74605_CE[Ra1]_F(SHU)_QC(SD_IS)_PF1(RI_SS)_PFA(NC)_PN(IS).pdf
work_keys_str_mv AT vishalspatil managementofneglectedfloatingkneewithrotationaldeformityandlimbshorteningusingtheorthosuvframeacasereport
AT mohammedtalhamuneer managementofneglectedfloatingkneewithrotationaldeformityandlimbshorteningusingtheorthosuvframeacasereport
AT architgupta managementofneglectedfloatingkneewithrotationaldeformityandlimbshorteningusingtheorthosuvframeacasereport
AT rajkamble managementofneglectedfloatingkneewithrotationaldeformityandlimbshorteningusingtheorthosuvframeacasereport