Simulation of the effectiveness of longitudinal rectangular fins on the efficiency of the double pipe heat exchanger

In this article, a mathematical simulation of a double pipe heat exchanger is carried out, having the longitudinal rectangular fins with the dimension of (2*3*1000) mm, mounted on the outer surface of the inner tube of the heat exchanger. In this paper, the advantage of using of that type of fins an...

Full description

Saved in:
Bibliographic Details
Main Authors: N. F. Timerbaev, A. K. Ali, Omar Abdulhadi Mustafa Almohamed, A. R. Koryakin
Format: Article
Language:English
Published: Kazan State Power Engineering University 2019-12-01
Series:Известия высших учебных заведений: Проблемы энергетики
Subjects:
Online Access:https://www.energyret.ru/jour/article/view/1084