STUDIED ON AN IMPROVED CONSTITUTIVE MODEL AND SIMULATION FOR MILLING MEDICAL Ti-xNb-2Fe ALLOY

At present,medical Ti-xNb-2Fe alloy is widely used,but it still needs follow-up finishing in order to obtain high precision surface quality. The simulation process of Ti-xNb-2Fe alloy was established,a modified Johnson Cook( J-C)constitutive model considering the effects of strain,strain rate and te...

Full description

Saved in:
Bibliographic Details
Main Authors: JIANG XiaoHui, LI ShengChao, LI Qiang
Format: Article
Language:zho
Published: Editorial Office of Journal of Mechanical Strength 2021-01-01
Series:Jixie qiangdu
Subjects:
Online Access:http://www.jxqd.net.cn/thesisDetails#10.16579/j.issn.1001.9669.2021.03.023
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841535889330667520
author JIANG XiaoHui
LI ShengChao
LI Qiang
author_facet JIANG XiaoHui
LI ShengChao
LI Qiang
author_sort JIANG XiaoHui
collection DOAJ
description At present,medical Ti-xNb-2Fe alloy is widely used,but it still needs follow-up finishing in order to obtain high precision surface quality. The simulation process of Ti-xNb-2Fe alloy was established,a modified Johnson Cook( J-C)constitutive model considering the effects of strain,strain rate and temperature on flow stress was constructed. And a cutting physical parameters prediction method based on medical Ti-xNb-2Fe alloy was proposed in this work. First,the physical properties calculation software JMatPro was used to obtain the basic data of stress-strain curve of Ti-xNb-2Fe alloy during phase transformation,and the modified J-C model parameters were fitted by variable separation method. Then,on the platform of Advant Edge FEM finite element software,the flow stress model including phase transition was input into the software system through Fortran compiler. Finally,the data results of cutting force,cutting temperature and surface roughness simulated by J-C model and modified J-C model were compared with the physical testing results. The results indicated that the constitutive equation parameter A value and Bvalue decrease by 21% and 27% with the increase of trace element Nb content,respectively. The average percentage errors of cutting force,cutting temperature,surface roughness and physical testing results of finite element simulation using modified model were less than 25%,19% and 30%,respectively. The model can provide the optimization of process parameters for the follow-up finishing of medical Ti-xNb-2Fe alloy.
format Article
id doaj-art-bb315e80bbaa4eb3b8577635e8722eea
institution Kabale University
issn 1001-9669
language zho
publishDate 2021-01-01
publisher Editorial Office of Journal of Mechanical Strength
record_format Article
series Jixie qiangdu
spelling doaj-art-bb315e80bbaa4eb3b8577635e8722eea2025-01-15T02:25:59ZzhoEditorial Office of Journal of Mechanical StrengthJixie qiangdu1001-96692021-01-014366967930610864STUDIED ON AN IMPROVED CONSTITUTIVE MODEL AND SIMULATION FOR MILLING MEDICAL Ti-xNb-2Fe ALLOYJIANG XiaoHuiLI ShengChaoLI QiangAt present,medical Ti-xNb-2Fe alloy is widely used,but it still needs follow-up finishing in order to obtain high precision surface quality. The simulation process of Ti-xNb-2Fe alloy was established,a modified Johnson Cook( J-C)constitutive model considering the effects of strain,strain rate and temperature on flow stress was constructed. And a cutting physical parameters prediction method based on medical Ti-xNb-2Fe alloy was proposed in this work. First,the physical properties calculation software JMatPro was used to obtain the basic data of stress-strain curve of Ti-xNb-2Fe alloy during phase transformation,and the modified J-C model parameters were fitted by variable separation method. Then,on the platform of Advant Edge FEM finite element software,the flow stress model including phase transition was input into the software system through Fortran compiler. Finally,the data results of cutting force,cutting temperature and surface roughness simulated by J-C model and modified J-C model were compared with the physical testing results. The results indicated that the constitutive equation parameter A value and Bvalue decrease by 21% and 27% with the increase of trace element Nb content,respectively. The average percentage errors of cutting force,cutting temperature,surface roughness and physical testing results of finite element simulation using modified model were less than 25%,19% and 30%,respectively. The model can provide the optimization of process parameters for the follow-up finishing of medical Ti-xNb-2Fe alloy.http://www.jxqd.net.cn/thesisDetails#10.16579/j.issn.1001.9669.2021.03.023Medical alloyConstitutive modelFinite element simulationCutting forceCutting temperatureSurface roughness
spellingShingle JIANG XiaoHui
LI ShengChao
LI Qiang
STUDIED ON AN IMPROVED CONSTITUTIVE MODEL AND SIMULATION FOR MILLING MEDICAL Ti-xNb-2Fe ALLOY
Jixie qiangdu
Medical alloy
Constitutive model
Finite element simulation
Cutting force
Cutting temperature
Surface roughness
title STUDIED ON AN IMPROVED CONSTITUTIVE MODEL AND SIMULATION FOR MILLING MEDICAL Ti-xNb-2Fe ALLOY
title_full STUDIED ON AN IMPROVED CONSTITUTIVE MODEL AND SIMULATION FOR MILLING MEDICAL Ti-xNb-2Fe ALLOY
title_fullStr STUDIED ON AN IMPROVED CONSTITUTIVE MODEL AND SIMULATION FOR MILLING MEDICAL Ti-xNb-2Fe ALLOY
title_full_unstemmed STUDIED ON AN IMPROVED CONSTITUTIVE MODEL AND SIMULATION FOR MILLING MEDICAL Ti-xNb-2Fe ALLOY
title_short STUDIED ON AN IMPROVED CONSTITUTIVE MODEL AND SIMULATION FOR MILLING MEDICAL Ti-xNb-2Fe ALLOY
title_sort studied on an improved constitutive model and simulation for milling medical ti xnb 2fe alloy
topic Medical alloy
Constitutive model
Finite element simulation
Cutting force
Cutting temperature
Surface roughness
url http://www.jxqd.net.cn/thesisDetails#10.16579/j.issn.1001.9669.2021.03.023
work_keys_str_mv AT jiangxiaohui studiedonanimprovedconstitutivemodelandsimulationformillingmedicaltixnb2fealloy
AT lishengchao studiedonanimprovedconstitutivemodelandsimulationformillingmedicaltixnb2fealloy
AT liqiang studiedonanimprovedconstitutivemodelandsimulationformillingmedicaltixnb2fealloy