Micro-vibration assisted dual-layer spiral microneedles to rapidly extract dermal interstitial fluid for minimally invasive detection of glucose

Abstract Various hydrogels have been explored to create minimally invasive microneedles (MNs) to extract interstitial fluid (ISF). However, current methods are time-consuming and typically require 10–15 min to extract 3–5 mg of ISF. This study introduces two spiral-shaped swellable MN arrays: one ma...

Full description

Saved in:
Bibliographic Details
Main Authors: Khaled Mohammed Saifullah, Asim Mushtaq, Pouria Azarikhah, Philip D. Prewett, Graham J. Davies, Zahra Faraji Rad
Format: Article
Language:English
Published: Nature Publishing Group 2025-01-01
Series:Microsystems & Nanoengineering
Online Access:https://doi.org/10.1038/s41378-024-00850-x
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841544537317572608
author Khaled Mohammed Saifullah
Asim Mushtaq
Pouria Azarikhah
Philip D. Prewett
Graham J. Davies
Zahra Faraji Rad
author_facet Khaled Mohammed Saifullah
Asim Mushtaq
Pouria Azarikhah
Philip D. Prewett
Graham J. Davies
Zahra Faraji Rad
author_sort Khaled Mohammed Saifullah
collection DOAJ
description Abstract Various hydrogels have been explored to create minimally invasive microneedles (MNs) to extract interstitial fluid (ISF). However, current methods are time-consuming and typically require 10–15 min to extract 3–5 mg of ISF. This study introduces two spiral-shaped swellable MN arrays: one made of gelatin methacryloyl (GelMA) and polyvinyl alcohol (PVA), and the other incorporating a combination of PVA, polyvinylpyrrolidone (PVP), and hyaluronic acid (HA) for fast ISF extraction. These MN arrays demonstrated a rapid swelling ratio of 560 ± 79.6% and 370 ± 34.1% in artificial ISF within 10 min, respectively. Additionally, this study proposes a novel method that combines MNs with a custom-designed Arduino-based applicator vibrating at frequency ranges (50–100 Hz) to improve skin penetration efficiency, thereby enhancing the uptake of ISF in ex vivo. This dynamic combination enables GelMA/PVA MNs to rapidly uptake 6.41 ± 1.01 mg of ISF in just 5 min, while PVA/PVP/HA MNs extract 5.38 ± 0.77 mg of ISF within the same timeframe. To validate the capability of the MNs to recover glucose as the target biomarker, a mild heating procedure is used, followed by determining glucose concentration using a d-glucose content assay kit. The efficient extraction of ISF and glucose detection capabilities of the spiral MNs suggest their potential for rapid and minimally invasive biomarker sensing.
format Article
id doaj-art-ae6586bafb41447ea0dc5ea538b5727a
institution Kabale University
issn 2055-7434
language English
publishDate 2025-01-01
publisher Nature Publishing Group
record_format Article
series Microsystems & Nanoengineering
spelling doaj-art-ae6586bafb41447ea0dc5ea538b5727a2025-01-12T12:27:54ZengNature Publishing GroupMicrosystems & Nanoengineering2055-74342025-01-0111111810.1038/s41378-024-00850-xMicro-vibration assisted dual-layer spiral microneedles to rapidly extract dermal interstitial fluid for minimally invasive detection of glucoseKhaled Mohammed Saifullah0Asim Mushtaq1Pouria Azarikhah2Philip D. Prewett3Graham J. Davies4Zahra Faraji Rad5School of Engineering, University of Southern QueenslandCentre for Future Materials, Institute for Advanced Engineering and Space Sciences, University of Southern QueenslandSchool of Engineering, University of Southern QueenslandSchool of Engineering, University of BirminghamFaculty of Engineering, UNSW AustraliaSchool of Engineering, University of Southern QueenslandAbstract Various hydrogels have been explored to create minimally invasive microneedles (MNs) to extract interstitial fluid (ISF). However, current methods are time-consuming and typically require 10–15 min to extract 3–5 mg of ISF. This study introduces two spiral-shaped swellable MN arrays: one made of gelatin methacryloyl (GelMA) and polyvinyl alcohol (PVA), and the other incorporating a combination of PVA, polyvinylpyrrolidone (PVP), and hyaluronic acid (HA) for fast ISF extraction. These MN arrays demonstrated a rapid swelling ratio of 560 ± 79.6% and 370 ± 34.1% in artificial ISF within 10 min, respectively. Additionally, this study proposes a novel method that combines MNs with a custom-designed Arduino-based applicator vibrating at frequency ranges (50–100 Hz) to improve skin penetration efficiency, thereby enhancing the uptake of ISF in ex vivo. This dynamic combination enables GelMA/PVA MNs to rapidly uptake 6.41 ± 1.01 mg of ISF in just 5 min, while PVA/PVP/HA MNs extract 5.38 ± 0.77 mg of ISF within the same timeframe. To validate the capability of the MNs to recover glucose as the target biomarker, a mild heating procedure is used, followed by determining glucose concentration using a d-glucose content assay kit. The efficient extraction of ISF and glucose detection capabilities of the spiral MNs suggest their potential for rapid and minimally invasive biomarker sensing.https://doi.org/10.1038/s41378-024-00850-x
spellingShingle Khaled Mohammed Saifullah
Asim Mushtaq
Pouria Azarikhah
Philip D. Prewett
Graham J. Davies
Zahra Faraji Rad
Micro-vibration assisted dual-layer spiral microneedles to rapidly extract dermal interstitial fluid for minimally invasive detection of glucose
Microsystems & Nanoengineering
title Micro-vibration assisted dual-layer spiral microneedles to rapidly extract dermal interstitial fluid for minimally invasive detection of glucose
title_full Micro-vibration assisted dual-layer spiral microneedles to rapidly extract dermal interstitial fluid for minimally invasive detection of glucose
title_fullStr Micro-vibration assisted dual-layer spiral microneedles to rapidly extract dermal interstitial fluid for minimally invasive detection of glucose
title_full_unstemmed Micro-vibration assisted dual-layer spiral microneedles to rapidly extract dermal interstitial fluid for minimally invasive detection of glucose
title_short Micro-vibration assisted dual-layer spiral microneedles to rapidly extract dermal interstitial fluid for minimally invasive detection of glucose
title_sort micro vibration assisted dual layer spiral microneedles to rapidly extract dermal interstitial fluid for minimally invasive detection of glucose
url https://doi.org/10.1038/s41378-024-00850-x
work_keys_str_mv AT khaledmohammedsaifullah microvibrationassistedduallayerspiralmicroneedlestorapidlyextractdermalinterstitialfluidforminimallyinvasivedetectionofglucose
AT asimmushtaq microvibrationassistedduallayerspiralmicroneedlestorapidlyextractdermalinterstitialfluidforminimallyinvasivedetectionofglucose
AT pouriaazarikhah microvibrationassistedduallayerspiralmicroneedlestorapidlyextractdermalinterstitialfluidforminimallyinvasivedetectionofglucose
AT philipdprewett microvibrationassistedduallayerspiralmicroneedlestorapidlyextractdermalinterstitialfluidforminimallyinvasivedetectionofglucose
AT grahamjdavies microvibrationassistedduallayerspiralmicroneedlestorapidlyextractdermalinterstitialfluidforminimallyinvasivedetectionofglucose
AT zahrafarajirad microvibrationassistedduallayerspiralmicroneedlestorapidlyextractdermalinterstitialfluidforminimallyinvasivedetectionofglucose