Investigation of the effect of impact load on concrete-filled steel tube columns under fire

Concrete-filled steel tube (CFST) columns are increasingly used in the construction of high-rise buildings which require high strength and large working space especially at lower stories. As compared to reinforced concrete columns, existence of the exterior steel tube not only bears a portion of axi...

Full description

Saved in:
Bibliographic Details
Main Authors: Ali Golsoorat Pahlaviani, Ali Mohammad Rousta, Peyman Beiranvand
Format: Article
Language:English
Published: Gruppo Italiano Frattura 2020-09-01
Series:Fracture and Structural Integrity
Subjects:
Online Access:https://www.fracturae.com/index.php/fis/article/view/2917
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841562793043558400
author Ali Golsoorat Pahlaviani
Ali Mohammad Rousta
Peyman Beiranvand
author_facet Ali Golsoorat Pahlaviani
Ali Mohammad Rousta
Peyman Beiranvand
author_sort Ali Golsoorat Pahlaviani
collection DOAJ
description Concrete-filled steel tube (CFST) columns are increasingly used in the construction of high-rise buildings which require high strength and large working space especially at lower stories. As compared to reinforced concrete columns, existence of the exterior steel tube not only bears a portion of axial load but also most importantly provides confinement to the infill concrete.with the confinement provided by the steel tube, axial strength of the infill concrete can be largely enhanced.this paper presents the investigation effect of impact load on concrete-filled steel tube columns under fire by numerical simulations using ABAQUS software.the results indicate that the CFST sections with larger confinement factor ξ=1.23 behaved in a very ductile manner under lateral impact. And the sections with smaller confinement factor ξ=0.44  generally behaved in a brittle mechanism.
format Article
id doaj-art-a8b64041bd174baca1eb11e8fb11bac6
institution Kabale University
issn 1971-8993
language English
publishDate 2020-09-01
publisher Gruppo Italiano Frattura
record_format Article
series Fracture and Structural Integrity
spelling doaj-art-a8b64041bd174baca1eb11e8fb11bac62025-01-03T00:40:24ZengGruppo Italiano FratturaFracture and Structural Integrity1971-89932020-09-011454Investigation of the effect of impact load on concrete-filled steel tube columns under fireAli Golsoorat Pahlaviani0Ali Mohammad Rousta1Peyman Beiranvand2Central Tehran Branch, Islamic Azad University, Tehran.Department of Civil Engineering, Yasouj University, Yasouj.Department of Civil Engineering, Razi University, Kermanshah.Concrete-filled steel tube (CFST) columns are increasingly used in the construction of high-rise buildings which require high strength and large working space especially at lower stories. As compared to reinforced concrete columns, existence of the exterior steel tube not only bears a portion of axial load but also most importantly provides confinement to the infill concrete.with the confinement provided by the steel tube, axial strength of the infill concrete can be largely enhanced.this paper presents the investigation effect of impact load on concrete-filled steel tube columns under fire by numerical simulations using ABAQUS software.the results indicate that the CFST sections with larger confinement factor ξ=1.23 behaved in a very ductile manner under lateral impact. And the sections with smaller confinement factor ξ=0.44  generally behaved in a brittle mechanism.https://www.fracturae.com/index.php/fis/article/view/2917Concrete-Filled Steel TubeImpact loadConfinement factor
spellingShingle Ali Golsoorat Pahlaviani
Ali Mohammad Rousta
Peyman Beiranvand
Investigation of the effect of impact load on concrete-filled steel tube columns under fire
Fracture and Structural Integrity
Concrete-Filled Steel Tube
Impact load
Confinement factor
title Investigation of the effect of impact load on concrete-filled steel tube columns under fire
title_full Investigation of the effect of impact load on concrete-filled steel tube columns under fire
title_fullStr Investigation of the effect of impact load on concrete-filled steel tube columns under fire
title_full_unstemmed Investigation of the effect of impact load on concrete-filled steel tube columns under fire
title_short Investigation of the effect of impact load on concrete-filled steel tube columns under fire
title_sort investigation of the effect of impact load on concrete filled steel tube columns under fire
topic Concrete-Filled Steel Tube
Impact load
Confinement factor
url https://www.fracturae.com/index.php/fis/article/view/2917
work_keys_str_mv AT aligolsooratpahlaviani investigationoftheeffectofimpactloadonconcretefilledsteeltubecolumnsunderfire
AT alimohammadrousta investigationoftheeffectofimpactloadonconcretefilledsteeltubecolumnsunderfire
AT peymanbeiranvand investigationoftheeffectofimpactloadonconcretefilledsteeltubecolumnsunderfire