Research on Opening Reignition Characteristics and Suppression Measures of 750 kV AC Filter Circuit Breakers

The operation of converter valves in converter stations often results in high reactive power consumption and harmonic generation, necessitating measures to maintain reactive power balance and ensure power quality. To achieve this, the filter bank circuit breaker is frequently switched on and off dur...

Full description

Saved in:
Bibliographic Details
Main Authors: Jianguo Zhang, Pengcheng Sha, Feiyue Ma, Bo Niu, Xu Cai, Hui Ni, Junbo Deng
Format: Article
Language:English
Published: MDPI AG 2025-01-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/18/1/218
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841549223769669632
author Jianguo Zhang
Pengcheng Sha
Feiyue Ma
Bo Niu
Xu Cai
Hui Ni
Junbo Deng
author_facet Jianguo Zhang
Pengcheng Sha
Feiyue Ma
Bo Niu
Xu Cai
Hui Ni
Junbo Deng
author_sort Jianguo Zhang
collection DOAJ
description The operation of converter valves in converter stations often results in high reactive power consumption and harmonic generation, necessitating measures to maintain reactive power balance and ensure power quality. To achieve this, the filter bank circuit breaker is frequently switched on and off during daily operation. In recent years, multiple incidents of circuit breaker breakdown during the opening process have been reported. In this study, power systems computer-aided design (PSCAD)/electromagnetic transients including DC (EMTDC) V5.0 electromagnetic transient simulation software is used to simulate and calculate the overvoltage and inrush current under different configurations of circuit breaker operating mechanism dispersion, opening phase angle, and operating speed. Additionally, the suppression effects of two measures are compared: “phase selection opening” and “phase selection opening combined with controlled opening speed” to mitigate overvoltage and inrush current. The results demonstrate that for BP11/13 filters, HP24/36 filters, and HP3 filters, the combined strategy of “phase-selective opening with controlled opening speed” is more effective in suppressing inrush current and overvoltage. However, for SC filters, the suppression effect of this combined strategy is not significant. Considering economic and practical factors, it is more reasonable to adopt the phase-selective opening measure for SC filters. These findings provide guidance for ensuring the safe operation of AC filter circuit breakers.
format Article
id doaj-art-9fd668a0119a4af4bbf7321a60bf9fc6
institution Kabale University
issn 1996-1073
language English
publishDate 2025-01-01
publisher MDPI AG
record_format Article
series Energies
spelling doaj-art-9fd668a0119a4af4bbf7321a60bf9fc62025-01-10T13:17:27ZengMDPI AGEnergies1996-10732025-01-0118121810.3390/en18010218Research on Opening Reignition Characteristics and Suppression Measures of 750 kV AC Filter Circuit BreakersJianguo Zhang0Pengcheng Sha1Feiyue Ma2Bo Niu3Xu Cai4Hui Ni5Junbo Deng6State Grid Ningxia Electric Power Research Institute, Yinchuan 750001, ChinaState Key Lab of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049, ChinaState Grid Ningxia Electric Power Research Institute, Yinchuan 750001, ChinaState Grid Ningxia Electric Power Research Institute, Yinchuan 750001, ChinaState Key Lab of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049, ChinaState Grid Ningxia Electric Power Research Institute, Yinchuan 750001, ChinaState Key Lab of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049, ChinaThe operation of converter valves in converter stations often results in high reactive power consumption and harmonic generation, necessitating measures to maintain reactive power balance and ensure power quality. To achieve this, the filter bank circuit breaker is frequently switched on and off during daily operation. In recent years, multiple incidents of circuit breaker breakdown during the opening process have been reported. In this study, power systems computer-aided design (PSCAD)/electromagnetic transients including DC (EMTDC) V5.0 electromagnetic transient simulation software is used to simulate and calculate the overvoltage and inrush current under different configurations of circuit breaker operating mechanism dispersion, opening phase angle, and operating speed. Additionally, the suppression effects of two measures are compared: “phase selection opening” and “phase selection opening combined with controlled opening speed” to mitigate overvoltage and inrush current. The results demonstrate that for BP11/13 filters, HP24/36 filters, and HP3 filters, the combined strategy of “phase-selective opening with controlled opening speed” is more effective in suppressing inrush current and overvoltage. However, for SC filters, the suppression effect of this combined strategy is not significant. Considering economic and practical factors, it is more reasonable to adopt the phase-selective opening measure for SC filters. These findings provide guidance for ensuring the safe operation of AC filter circuit breakers.https://www.mdpi.com/1996-1073/18/1/218AC filter bank circuit breakerarc modelopen switch reignitionopening speedopening phase angle
spellingShingle Jianguo Zhang
Pengcheng Sha
Feiyue Ma
Bo Niu
Xu Cai
Hui Ni
Junbo Deng
Research on Opening Reignition Characteristics and Suppression Measures of 750 kV AC Filter Circuit Breakers
Energies
AC filter bank circuit breaker
arc model
open switch reignition
opening speed
opening phase angle
title Research on Opening Reignition Characteristics and Suppression Measures of 750 kV AC Filter Circuit Breakers
title_full Research on Opening Reignition Characteristics and Suppression Measures of 750 kV AC Filter Circuit Breakers
title_fullStr Research on Opening Reignition Characteristics and Suppression Measures of 750 kV AC Filter Circuit Breakers
title_full_unstemmed Research on Opening Reignition Characteristics and Suppression Measures of 750 kV AC Filter Circuit Breakers
title_short Research on Opening Reignition Characteristics and Suppression Measures of 750 kV AC Filter Circuit Breakers
title_sort research on opening reignition characteristics and suppression measures of 750 kv ac filter circuit breakers
topic AC filter bank circuit breaker
arc model
open switch reignition
opening speed
opening phase angle
url https://www.mdpi.com/1996-1073/18/1/218
work_keys_str_mv AT jianguozhang researchonopeningreignitioncharacteristicsandsuppressionmeasuresof750kvacfiltercircuitbreakers
AT pengchengsha researchonopeningreignitioncharacteristicsandsuppressionmeasuresof750kvacfiltercircuitbreakers
AT feiyuema researchonopeningreignitioncharacteristicsandsuppressionmeasuresof750kvacfiltercircuitbreakers
AT boniu researchonopeningreignitioncharacteristicsandsuppressionmeasuresof750kvacfiltercircuitbreakers
AT xucai researchonopeningreignitioncharacteristicsandsuppressionmeasuresof750kvacfiltercircuitbreakers
AT huini researchonopeningreignitioncharacteristicsandsuppressionmeasuresof750kvacfiltercircuitbreakers
AT junbodeng researchonopeningreignitioncharacteristicsandsuppressionmeasuresof750kvacfiltercircuitbreakers