Neuronal Multi Unit Activity Processing with Metal Oxide Memristive Devices

Abstract Intra‐cortical brain‐machine interfaces (BMIs), able to decode neural activity in real‐time, represent a revolutionary opportunity for treating medical conditions. However, traditional systems focusing on single‐neuron spike detection require high processing rates and power, hindering the u...

Full description

Saved in:
Bibliographic Details
Main Authors: Caterina Sbandati, Xiongfei Jiang, Deepika Yadav, Spyros Stathopoulos, Dana Cohen, Alex Serb, Shiwei Wang, Themis Prodromakis
Format: Article
Language:English
Published: Wiley-VCH 2024-12-01
Series:Advanced Electronic Materials
Subjects:
Online Access:https://doi.org/10.1002/aelm.202400638
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Abstract Intra‐cortical brain‐machine interfaces (BMIs), able to decode neural activity in real‐time, represent a revolutionary opportunity for treating medical conditions. However, traditional systems focusing on single‐neuron spike detection require high processing rates and power, hindering the up‐scaling for neurons‐population monitoring in clinical application. An intriguing proposition is the memristive integrating sensor (MIS) approach, which uses resistive RAM (RRAM) for threshold‐based neural activity detection. MIS leverages analogue multi‐state switching properties of metal‐oxide RRAM to compress neural inputs by encoding above‐threshold events in resistance displacement, facilitating efficient data down‐sampling in the post‐processing, enabling low‐power, high‐channel systems. Initially tested on spikes and local field potentials, here MIS is adapted to process multi‐unit activity envelope (eMUA)—the envelope of entire spiking activity—which has recently been proposed as crucial input for real‐time neuro‐prosthetic control. Prior necessary modifications to the MIS for effective operation, this adaptation achieved over 95% sensitivity across two types of metal‐oxide devices: Pt/TiOx/Pt and TiN/HfOx/TiN, proving its platform‐agnostic capabilities. Furthermore, towards the integration of MIS with silicon chips, it is shown that it can reduce total system power consumption to below 1 µW, as RRAM encoding stage relaxes the signal preservation and noise requirements that challenge traditional complementary metal‐oxide‐semiconductor (CMOS) front‐ends. This eMUA‐MIS adaptation offers a viable pathway for developing more scalable and efficient BMIs for clinical use.
ISSN:2199-160X