Background:: Single incision slings (SIS) and adjustable single incision slings (ASIS) are the latest generation of midurethral slings (MUS), used for the surgical treatment of female stress urinary incontinence, that seek to minimize the morbidity and complications associated to the conventional re...

Full description

Saved in:
Bibliographic Details
Main Authors: E. Collier, S. Housmans, F. Van der Aa
Format: Article
Language:English
Published: Elsevier 2025-03-01
Series:Continence
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2772973724010166
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841561279276253184
author E. Collier
S. Housmans
F. Van der Aa
author_facet E. Collier
S. Housmans
F. Van der Aa
author_sort E. Collier
collection DOAJ
description Background:: Single incision slings (SIS) and adjustable single incision slings (ASIS) are the latest generation of midurethral slings (MUS), used for the surgical treatment of female stress urinary incontinence, that seek to minimize the morbidity and complications associated to the conventional retropubic and transobturator midurethral slings. Its use has recently come under scrutiny following concerns about long-term complications. Aims:: We conducted an internal audit of the short-to-medium term safety and absence of reported complications of the Altis® SIS in our medical centre (University Hospital of Leuven, Belgium). Secondary outcome was treatment efficacy, defined as no self-reported SUI symptoms. Methods:: A file review of all patients implanted with an Altis® sling at our institution between 2014 and May 2021 was performed. Baseline characteristics and outcomes were reported with the use of descriptive statistics. Results:: 212 women were included in our safety analysis, 192 women in the efficacy analysis. The safety analysis showed 74 complications of any kind. Mesh exposure occurred in 16 women (7.5%) after a mean period of 15 months. Eleven of them (5.2%) underwent excision of the exposed mesh. Arterial haemorrhage requiring embolization, and mesh infection, both occurred once. Dyspareunia for the patient (3.3%) or her partner (1.4%) was encountered in nine cases. Four cases were linked to mesh exposure, of which three underwent partial sling excision. De novo urgency (5.7%) and urge incontinence (7.3%) were reported in 25 women (13%) and were managed with anticholinergic drugs. Regarding efficacy outcomes, 161 women (83.8%) reported no residual urine loss at the first post-operative consultation. Thirteen women (6.7%) had persistent SUI. Eight women (4.2%) underwent reintervention receiving a second sling. Conclusion:: We can conclude that the short-to-medium term results in our centre align with those reported in existing literature.
format Article
id doaj-art-995c9d4952964852893a9d4d031e6dd1
institution Kabale University
issn 2772-9737
language English
publishDate 2025-03-01
publisher Elsevier
record_format Article
series Continence
spelling doaj-art-995c9d4952964852893a9d4d031e6dd12025-01-03T04:09:04ZengElsevierContinence2772-97372025-03-0113101741A retrospective, single-centre safety audit of the Altis® single incision sling in the surgical treatment of female stress urinary incontinenceE. Collier0S. Housmans1F. Van der Aa2Department of Urology, UZ Leuven, Leuven, Belgium; Correspondence to: Hertogweg 23, 1970 Wezembeek-Oppem, Belgium.Department of Gynaecology, UZ Leuven, Leuven, BelgiumDepartment of Urology, UZ Leuven, Leuven, BelgiumBackground:: Single incision slings (SIS) and adjustable single incision slings (ASIS) are the latest generation of midurethral slings (MUS), used for the surgical treatment of female stress urinary incontinence, that seek to minimize the morbidity and complications associated to the conventional retropubic and transobturator midurethral slings. Its use has recently come under scrutiny following concerns about long-term complications. Aims:: We conducted an internal audit of the short-to-medium term safety and absence of reported complications of the Altis® SIS in our medical centre (University Hospital of Leuven, Belgium). Secondary outcome was treatment efficacy, defined as no self-reported SUI symptoms. Methods:: A file review of all patients implanted with an Altis® sling at our institution between 2014 and May 2021 was performed. Baseline characteristics and outcomes were reported with the use of descriptive statistics. Results:: 212 women were included in our safety analysis, 192 women in the efficacy analysis. The safety analysis showed 74 complications of any kind. Mesh exposure occurred in 16 women (7.5%) after a mean period of 15 months. Eleven of them (5.2%) underwent excision of the exposed mesh. Arterial haemorrhage requiring embolization, and mesh infection, both occurred once. Dyspareunia for the patient (3.3%) or her partner (1.4%) was encountered in nine cases. Four cases were linked to mesh exposure, of which three underwent partial sling excision. De novo urgency (5.7%) and urge incontinence (7.3%) were reported in 25 women (13%) and were managed with anticholinergic drugs. Regarding efficacy outcomes, 161 women (83.8%) reported no residual urine loss at the first post-operative consultation. Thirteen women (6.7%) had persistent SUI. Eight women (4.2%) underwent reintervention receiving a second sling. Conclusion:: We can conclude that the short-to-medium term results in our centre align with those reported in existing literature.http://www.sciencedirect.com/science/article/pii/S2772973724010166Safety auditAltis® single incision slingStress urinary incontinence
spellingShingle E. Collier
S. Housmans
F. Van der Aa
A retrospective, single-centre safety audit of the Altis® single incision sling in the surgical treatment of female stress urinary incontinence
Continence
Safety audit
Altis® single incision sling
Stress urinary incontinence
title A retrospective, single-centre safety audit of the Altis® single incision sling in the surgical treatment of female stress urinary incontinence
title_full A retrospective, single-centre safety audit of the Altis® single incision sling in the surgical treatment of female stress urinary incontinence
title_fullStr A retrospective, single-centre safety audit of the Altis® single incision sling in the surgical treatment of female stress urinary incontinence
title_full_unstemmed A retrospective, single-centre safety audit of the Altis® single incision sling in the surgical treatment of female stress urinary incontinence
title_short A retrospective, single-centre safety audit of the Altis® single incision sling in the surgical treatment of female stress urinary incontinence
title_sort retrospective single centre safety audit of the altis r single incision sling in the surgical treatment of female stress urinary incontinence
topic Safety audit
Altis® single incision sling
Stress urinary incontinence
url http://www.sciencedirect.com/science/article/pii/S2772973724010166
work_keys_str_mv AT ecollier aretrospectivesinglecentresafetyauditofthealtissingleincisionslinginthesurgicaltreatmentoffemalestressurinaryincontinence
AT shousmans aretrospectivesinglecentresafetyauditofthealtissingleincisionslinginthesurgicaltreatmentoffemalestressurinaryincontinence
AT fvanderaa aretrospectivesinglecentresafetyauditofthealtissingleincisionslinginthesurgicaltreatmentoffemalestressurinaryincontinence
AT ecollier retrospectivesinglecentresafetyauditofthealtissingleincisionslinginthesurgicaltreatmentoffemalestressurinaryincontinence
AT shousmans retrospectivesinglecentresafetyauditofthealtissingleincisionslinginthesurgicaltreatmentoffemalestressurinaryincontinence
AT fvanderaa retrospectivesinglecentresafetyauditofthealtissingleincisionslinginthesurgicaltreatmentoffemalestressurinaryincontinence