Novel ultralow positioning of the umbilical artery catheter: A prospective pilot study

Thrombosis is a common complication of umbilical artery catheterization. The purpose of this study was to compare the novel ultralow umbilical artery catheter position (catheter tip at the junction of the umbilical and internal iliac arteries) versus the conventional high umbilical artery catheter p...

Full description

Saved in:
Bibliographic Details
Main Authors: Tomaszkiewicz Anna, Szymański Piotr, Kruczek Piotr
Format: Article
Language:English
Published: Sciendo 2024-11-01
Series:Journal of Ultrasonography
Subjects:
Online Access:https://doi.org/10.15557/jou.2024.0024
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841556496809197568
author Tomaszkiewicz Anna
Szymański Piotr
Kruczek Piotr
author_facet Tomaszkiewicz Anna
Szymański Piotr
Kruczek Piotr
author_sort Tomaszkiewicz Anna
collection DOAJ
description Thrombosis is a common complication of umbilical artery catheterization. The purpose of this study was to compare the novel ultralow umbilical artery catheter position (catheter tip at the junction of the umbilical and internal iliac arteries) versus the conventional high umbilical artery catheter position (tip in the aorta, above the diaphragm) for the incidence of thrombosis.
format Article
id doaj-art-5da6eccd31e24ca199faf3a9ebe12014
institution Kabale University
issn 2451-070X
language English
publishDate 2024-11-01
publisher Sciendo
record_format Article
series Journal of Ultrasonography
spelling doaj-art-5da6eccd31e24ca199faf3a9ebe120142025-01-07T07:56:28ZengSciendoJournal of Ultrasonography2451-070X2024-11-0124981610.15557/jou.2024.0024Novel ultralow positioning of the umbilical artery catheter: A prospective pilot studyTomaszkiewicz Anna0Szymański Piotr1Kruczek Piotr21Department of Neonatology, Poznan University of Medical Sciences, Poznan, Poland2Past address: Department of Neonatology, Ujastek Medical Center, Cracow, Poland2Past address: Department of Neonatology, Ujastek Medical Center, Cracow, PolandThrombosis is a common complication of umbilical artery catheterization. The purpose of this study was to compare the novel ultralow umbilical artery catheter position (catheter tip at the junction of the umbilical and internal iliac arteries) versus the conventional high umbilical artery catheter position (tip in the aorta, above the diaphragm) for the incidence of thrombosis.https://doi.org/10.15557/jou.2024.0024thrombosisneonateultrasound examinationumbilical artery cathetercatheter position
spellingShingle Tomaszkiewicz Anna
Szymański Piotr
Kruczek Piotr
Novel ultralow positioning of the umbilical artery catheter: A prospective pilot study
Journal of Ultrasonography
thrombosis
neonate
ultrasound examination
umbilical artery catheter
catheter position
title Novel ultralow positioning of the umbilical artery catheter: A prospective pilot study
title_full Novel ultralow positioning of the umbilical artery catheter: A prospective pilot study
title_fullStr Novel ultralow positioning of the umbilical artery catheter: A prospective pilot study
title_full_unstemmed Novel ultralow positioning of the umbilical artery catheter: A prospective pilot study
title_short Novel ultralow positioning of the umbilical artery catheter: A prospective pilot study
title_sort novel ultralow positioning of the umbilical artery catheter a prospective pilot study
topic thrombosis
neonate
ultrasound examination
umbilical artery catheter
catheter position
url https://doi.org/10.15557/jou.2024.0024
work_keys_str_mv AT tomaszkiewiczanna novelultralowpositioningoftheumbilicalarterycatheteraprospectivepilotstudy
AT szymanskipiotr novelultralowpositioningoftheumbilicalarterycatheteraprospectivepilotstudy
AT kruczekpiotr novelultralowpositioningoftheumbilicalarterycatheteraprospectivepilotstudy