Derating factor determination of the three‐phase induction motor under unbalanced voltage using pumping system

Abstract A novel method is presented for determining the derating factors of a three‐phase induction motor under the condition of the unbalanced supply voltages. In this method, a mechanical system is used which consist of the a centrifugal pump, two valves, a DC motor, which are connected to the sh...