Evaluation of Flexural Strength and Microhardness of Different Type Glass Ionomer Cements

AbstractPurpose: The aim of this study is to evaluate and compare flexural strength and microhardness of different types of glass ionomer cements (Fuji IX GP® Fast, Riva LC HV, EQUIA Forte Fil).Materials and Methods: A total of 30 samples (n = 10) were prepared for microhard...

Full description

Saved in:
Bibliographic Details
Main Authors: Kübra Bilge, Enes Mustafa Aşar, İrem İpek
Format: Article
Language:English
Published: Ankara University 2024-04-01
Series:European Annals of Dental Sciences
Online Access:https://dergipark.org.tr/en/doi/10.52037/eads.2024.0002
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841525450739810304
author Kübra Bilge
Enes Mustafa Aşar
İrem İpek
author_facet Kübra Bilge
Enes Mustafa Aşar
İrem İpek
author_sort Kübra Bilge
collection DOAJ
description AbstractPurpose: The aim of this study is to evaluate and compare flexural strength and microhardness of different types of glass ionomer cements (Fuji IX GP® Fast, Riva LC HV, EQUIA Forte Fil).Materials and Methods: A total of 30 samples (n = 10) were prepared for microhardness test, and an additional total of 30 samples (n = 10) were prepared for the flexural strength test. Customized stainless steel molds (25×2×2 mm³) were produced for the flexural strength test, and 10 mm and 2 mm plexiglass molds were produced for the microhardness test. The prepared samples were stored in distilled water in a dark bottle at 37 °C (±1 °C) for 24 hours. A three-point bending test was performed using a universal testing device, and the maximum force values required to fracture the samples were determined in Newton by the device after the fracture. For the Vickers microhardness test measurements were made from different areas of the upper surfaces of each sample and the average of five measurements was calculated in MPa.Results: When comparing the flexural strength values, EQUIA Forte Fil group observed the highest flexural strength value, while Riva LC HV group had lowest flexural strength value. When comparing the microhardness values, EQUIA Forte Fil group showed the highest microhardness value, whereas Riva LC HV group observed the lowest microhardness value.Conclusion: The use of EQUIA Forte Fil, which has the highest microhardness and flexural strength values, and similarly strengthened glass ionomer cements may enhance clinical success.Key Words: glass ionomer cements; microhardness; flexural strength
format Article
id doaj-art-5206c67527d54442ace958ba2ce8f9f1
institution Kabale University
issn 2757-6744
language English
publishDate 2024-04-01
publisher Ankara University
record_format Article
series European Annals of Dental Sciences
spelling doaj-art-5206c67527d54442ace958ba2ce8f9f12025-01-17T11:28:06ZengAnkara UniversityEuropean Annals of Dental Sciences2757-67442024-04-01511101410.52037/eads.2024.0002 Evaluation of Flexural Strength and Microhardness of Different Type Glass Ionomer Cements Kübra Bilge0https://orcid.org/0000-0002-4323-9316Enes Mustafa Aşar1https://orcid.org/0000-0003-3432-8584İrem İpek2https://orcid.org/0000-0002-3542-7122FIRAT ÜNİVERSİTESİ DİŞ HEKİMLİĞİ FAKÜLTESİSELÇUK ÜNİVERSİTESİ DİŞ HEKİMLİĞİ FAKÜLTESİ PEDODONTİ ANABİLİM DALIFIRAT ÜNİVERSİTESİ DİŞ HEKİMLİĞİ FAKÜLTESİ PEDODONTİ ANABİLİM DALI AbstractPurpose: The aim of this study is to evaluate and compare flexural strength and microhardness of different types of glass ionomer cements (Fuji IX GP® Fast, Riva LC HV, EQUIA Forte Fil).Materials and Methods: A total of 30 samples (n = 10) were prepared for microhardness test, and an additional total of 30 samples (n = 10) were prepared for the flexural strength test. Customized stainless steel molds (25×2×2 mm³) were produced for the flexural strength test, and 10 mm and 2 mm plexiglass molds were produced for the microhardness test. The prepared samples were stored in distilled water in a dark bottle at 37 °C (±1 °C) for 24 hours. A three-point bending test was performed using a universal testing device, and the maximum force values required to fracture the samples were determined in Newton by the device after the fracture. For the Vickers microhardness test measurements were made from different areas of the upper surfaces of each sample and the average of five measurements was calculated in MPa.Results: When comparing the flexural strength values, EQUIA Forte Fil group observed the highest flexural strength value, while Riva LC HV group had lowest flexural strength value. When comparing the microhardness values, EQUIA Forte Fil group showed the highest microhardness value, whereas Riva LC HV group observed the lowest microhardness value.Conclusion: The use of EQUIA Forte Fil, which has the highest microhardness and flexural strength values, and similarly strengthened glass ionomer cements may enhance clinical success.Key Words: glass ionomer cements; microhardness; flexural strengthhttps://dergipark.org.tr/en/doi/10.52037/eads.2024.0002
spellingShingle Kübra Bilge
Enes Mustafa Aşar
İrem İpek
Evaluation of Flexural Strength and Microhardness of Different Type Glass Ionomer Cements
European Annals of Dental Sciences
title Evaluation of Flexural Strength and Microhardness of Different Type Glass Ionomer Cements
title_full Evaluation of Flexural Strength and Microhardness of Different Type Glass Ionomer Cements
title_fullStr Evaluation of Flexural Strength and Microhardness of Different Type Glass Ionomer Cements
title_full_unstemmed Evaluation of Flexural Strength and Microhardness of Different Type Glass Ionomer Cements
title_short Evaluation of Flexural Strength and Microhardness of Different Type Glass Ionomer Cements
title_sort evaluation of flexural strength and microhardness of different type glass ionomer cements
url https://dergipark.org.tr/en/doi/10.52037/eads.2024.0002
work_keys_str_mv AT kubrabilge evaluationofflexuralstrengthandmicrohardnessofdifferenttypeglassionomercements
AT enesmustafaasar evaluationofflexuralstrengthandmicrohardnessofdifferenttypeglassionomercements
AT iremipek evaluationofflexuralstrengthandmicrohardnessofdifferenttypeglassionomercements