Evaluation of the Arjun’s Royal Air Force Device as a New Tool for Assessing Near Point of Convergence and Near Point of Accommodation

Context: The Arjun’s Royal Air Force (ARAF) device is a newly developed digital tool designed to assess near point of convergence (NPC) and near point of accommodation (NPA). It aims to address the limitations of the traditional Royal Air Force (RAF) rule by enhancing precision, comfort, and clinica...

Full description

Saved in:
Bibliographic Details
Main Authors: Ankit Sanjay Varshney, Sanjay Mehta, Chetna Suresh Patel, Mahendrasinh D. Chauhan
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2025-01-01
Series:Delhi Journal of Ophthalmology
Subjects:
Online Access:https://journals.lww.com/10.4103/DLJO.DLJO_188_24
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1849314317090947072
author Ankit Sanjay Varshney
Sanjay Mehta
Chetna Suresh Patel
Mahendrasinh D. Chauhan
author_facet Ankit Sanjay Varshney
Sanjay Mehta
Chetna Suresh Patel
Mahendrasinh D. Chauhan
author_sort Ankit Sanjay Varshney
collection DOAJ
description Context: The Arjun’s Royal Air Force (ARAF) device is a newly developed digital tool designed to assess near point of convergence (NPC) and near point of accommodation (NPA). It aims to address the limitations of the traditional Royal Air Force (RAF) rule by enhancing precision, comfort, and clinical usability. Aims: This aims to evaluate the accuracy, efficacy, and user satisfaction of the ARAF device compared to the RAF rule in assessing NPC and NPA. Settings and Design: A prospective observational study was conducted at a tertiary eye care center, involving 56 participants with a mean age of 21.55 ± 5.36 years. Subjects and Methods: Participants underwent NPC and NPA assessments using both the ARAF device and the RAF rule. The order of device usage was randomized, with three trials per device for each participant. Subjective feedback on comfort and usability was collected using a structured questionnaire. Statistical Analysis Used: The Wilcoxon signed-rank test was used for statistical comparison, with significance set at P < 0.05. Results: The ARAF device demonstrated statistically significant improvements in measurement precision for NPC (P = 0.004) and NPA (monocular: P <0.01; binocular: P = 0.003) compared to the RAF rule. Effect sizes indicated a moderate impact favoring the ARAF device. Subjective feedback showed that 53.57% of participants rated the ARAF device as more comfortable and user-friendly, highlighting its ergonomic design and automated digital readout as advantages. Preference for the RAF rule was limited to 28.57%, while 17.85% expressed no preference. Conclusions: The ARAF device provides a precise, reliable, and user-friendly alternative to the RAF rule for NPC and NPA assessments. Its automation enhances diagnostic accuracy, reduces examiner fatigue, and improves patient comfort, making it valuable for high-throughput clinical settings and in pediatric or geriatric care. Further studies with diverse populations are recommended to validate these findings.
format Article
id doaj-art-4035dafb50ae4cbba2b5b6a84a25a9d8
institution Kabale University
issn 0972-0200
2454-2784
language English
publishDate 2025-01-01
publisher Wolters Kluwer Medknow Publications
record_format Article
series Delhi Journal of Ophthalmology
spelling doaj-art-4035dafb50ae4cbba2b5b6a84a25a9d82025-08-20T03:52:29ZengWolters Kluwer Medknow PublicationsDelhi Journal of Ophthalmology0972-02002454-27842025-01-01351283710.4103/DLJO.DLJO_188_24Evaluation of the Arjun’s Royal Air Force Device as a New Tool for Assessing Near Point of Convergence and Near Point of AccommodationAnkit Sanjay VarshneySanjay MehtaChetna Suresh PatelMahendrasinh D. ChauhanContext: The Arjun’s Royal Air Force (ARAF) device is a newly developed digital tool designed to assess near point of convergence (NPC) and near point of accommodation (NPA). It aims to address the limitations of the traditional Royal Air Force (RAF) rule by enhancing precision, comfort, and clinical usability. Aims: This aims to evaluate the accuracy, efficacy, and user satisfaction of the ARAF device compared to the RAF rule in assessing NPC and NPA. Settings and Design: A prospective observational study was conducted at a tertiary eye care center, involving 56 participants with a mean age of 21.55 ± 5.36 years. Subjects and Methods: Participants underwent NPC and NPA assessments using both the ARAF device and the RAF rule. The order of device usage was randomized, with three trials per device for each participant. Subjective feedback on comfort and usability was collected using a structured questionnaire. Statistical Analysis Used: The Wilcoxon signed-rank test was used for statistical comparison, with significance set at P < 0.05. Results: The ARAF device demonstrated statistically significant improvements in measurement precision for NPC (P = 0.004) and NPA (monocular: P <0.01; binocular: P = 0.003) compared to the RAF rule. Effect sizes indicated a moderate impact favoring the ARAF device. Subjective feedback showed that 53.57% of participants rated the ARAF device as more comfortable and user-friendly, highlighting its ergonomic design and automated digital readout as advantages. Preference for the RAF rule was limited to 28.57%, while 17.85% expressed no preference. Conclusions: The ARAF device provides a precise, reliable, and user-friendly alternative to the RAF rule for NPC and NPA assessments. Its automation enhances diagnostic accuracy, reduces examiner fatigue, and improves patient comfort, making it valuable for high-throughput clinical settings and in pediatric or geriatric care. Further studies with diverse populations are recommended to validate these findings.https://journals.lww.com/10.4103/DLJO.DLJO_188_24arjun’s royal air force devicebinocular vision assessmentdigital optometry toolsnear point of accommodationnear point of convergenceraf rule
spellingShingle Ankit Sanjay Varshney
Sanjay Mehta
Chetna Suresh Patel
Mahendrasinh D. Chauhan
Evaluation of the Arjun’s Royal Air Force Device as a New Tool for Assessing Near Point of Convergence and Near Point of Accommodation
Delhi Journal of Ophthalmology
arjun’s royal air force device
binocular vision assessment
digital optometry tools
near point of accommodation
near point of convergence
raf rule
title Evaluation of the Arjun’s Royal Air Force Device as a New Tool for Assessing Near Point of Convergence and Near Point of Accommodation
title_full Evaluation of the Arjun’s Royal Air Force Device as a New Tool for Assessing Near Point of Convergence and Near Point of Accommodation
title_fullStr Evaluation of the Arjun’s Royal Air Force Device as a New Tool for Assessing Near Point of Convergence and Near Point of Accommodation
title_full_unstemmed Evaluation of the Arjun’s Royal Air Force Device as a New Tool for Assessing Near Point of Convergence and Near Point of Accommodation
title_short Evaluation of the Arjun’s Royal Air Force Device as a New Tool for Assessing Near Point of Convergence and Near Point of Accommodation
title_sort evaluation of the arjun s royal air force device as a new tool for assessing near point of convergence and near point of accommodation
topic arjun’s royal air force device
binocular vision assessment
digital optometry tools
near point of accommodation
near point of convergence
raf rule
url https://journals.lww.com/10.4103/DLJO.DLJO_188_24
work_keys_str_mv AT ankitsanjayvarshney evaluationofthearjunsroyalairforcedeviceasanewtoolforassessingnearpointofconvergenceandnearpointofaccommodation
AT sanjaymehta evaluationofthearjunsroyalairforcedeviceasanewtoolforassessingnearpointofconvergenceandnearpointofaccommodation
AT chetnasureshpatel evaluationofthearjunsroyalairforcedeviceasanewtoolforassessingnearpointofconvergenceandnearpointofaccommodation
AT mahendrasinhdchauhan evaluationofthearjunsroyalairforcedeviceasanewtoolforassessingnearpointofconvergenceandnearpointofaccommodation