Research of Tooth Profile Error Evaluation Method based on Cartesian Coordinate Measurement Method
The tooth profile error is one important individual errors of gear,with wide use of the coordinate measuring machine in gear measurement,the Cartesian coordinate measuring method is becoming more and more widely applied in gear error measurement field. The tooth profile error evaluation method is ta...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Language: | zho |
Published: |
Editorial Office of Journal of Mechanical Transmission
2016-01-01
|
Series: | Jixie chuandong |
Subjects: | |
Online Access: | http://www.jxcd.net.cn/thesisDetails#10.16578/j.issn.1004.2539.2016.08.003 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1841547958125854720 |
---|---|
author | Zhang Bai Lin Jiachun |
author_facet | Zhang Bai Lin Jiachun |
author_sort | Zhang Bai |
collection | DOAJ |
description | The tooth profile error is one important individual errors of gear,with wide use of the coordinate measuring machine in gear measurement,the Cartesian coordinate measuring method is becoming more and more widely applied in gear error measurement field. The tooth profile error evaluation method is taken as research subject,the tooth profile error measurement and evaluation methods in the Cartesian coordinate system are systematic researched. The whole process of tooth profile error measurement is introduced,which includes the establishment of gear workpiece coordinate system,tooth profile measurement path planning,and tooth profile error evaluation. The tooth profile error evaluation methods are detailed analyzed and compared,including geometric tooth profile error evaluation method,formula tooth profile error evaluation method and sliding tooth profile error evaluation method,then their algorithm accuracies and efficiencies are compared. The experimental results show that three profile error evaluation algorithms are up to 1 × 10<sup>-14</sup> level in aspect of accuracy. In aspect of measurement efficiency,the geometric profile error evaluation method is the lowest,formula profile error evaluation method is the highest,and efficiency rate is up to 94 times on the condition of 500 000 measurement points. So the formula profile error evaluation method is recommended in the practical application. |
format | Article |
id | doaj-art-3288fb3b998a43e48cc3029f257f41fb |
institution | Kabale University |
issn | 1004-2539 |
language | zho |
publishDate | 2016-01-01 |
publisher | Editorial Office of Journal of Mechanical Transmission |
record_format | Article |
series | Jixie chuandong |
spelling | doaj-art-3288fb3b998a43e48cc3029f257f41fb2025-01-10T14:16:11ZzhoEditorial Office of Journal of Mechanical TransmissionJixie chuandong1004-25392016-01-0140111529925514Research of Tooth Profile Error Evaluation Method based on Cartesian Coordinate Measurement MethodZhang BaiLin JiachunThe tooth profile error is one important individual errors of gear,with wide use of the coordinate measuring machine in gear measurement,the Cartesian coordinate measuring method is becoming more and more widely applied in gear error measurement field. The tooth profile error evaluation method is taken as research subject,the tooth profile error measurement and evaluation methods in the Cartesian coordinate system are systematic researched. The whole process of tooth profile error measurement is introduced,which includes the establishment of gear workpiece coordinate system,tooth profile measurement path planning,and tooth profile error evaluation. The tooth profile error evaluation methods are detailed analyzed and compared,including geometric tooth profile error evaluation method,formula tooth profile error evaluation method and sliding tooth profile error evaluation method,then their algorithm accuracies and efficiencies are compared. The experimental results show that three profile error evaluation algorithms are up to 1 × 10<sup>-14</sup> level in aspect of accuracy. In aspect of measurement efficiency,the geometric profile error evaluation method is the lowest,formula profile error evaluation method is the highest,and efficiency rate is up to 94 times on the condition of 500 000 measurement points. So the formula profile error evaluation method is recommended in the practical application.http://www.jxcd.net.cn/thesisDetails#10.16578/j.issn.1004.2539.2016.08.003Tooth profile errorCartesian coordinate measurement methodAlgorithm accuracyAlgorithm efficiency |
spellingShingle | Zhang Bai Lin Jiachun Research of Tooth Profile Error Evaluation Method based on Cartesian Coordinate Measurement Method Jixie chuandong Tooth profile error Cartesian coordinate measurement method Algorithm accuracy Algorithm efficiency |
title | Research of Tooth Profile Error Evaluation Method based on Cartesian Coordinate Measurement Method |
title_full | Research of Tooth Profile Error Evaluation Method based on Cartesian Coordinate Measurement Method |
title_fullStr | Research of Tooth Profile Error Evaluation Method based on Cartesian Coordinate Measurement Method |
title_full_unstemmed | Research of Tooth Profile Error Evaluation Method based on Cartesian Coordinate Measurement Method |
title_short | Research of Tooth Profile Error Evaluation Method based on Cartesian Coordinate Measurement Method |
title_sort | research of tooth profile error evaluation method based on cartesian coordinate measurement method |
topic | Tooth profile error Cartesian coordinate measurement method Algorithm accuracy Algorithm efficiency |
url | http://www.jxcd.net.cn/thesisDetails#10.16578/j.issn.1004.2539.2016.08.003 |
work_keys_str_mv | AT zhangbai researchoftoothprofileerrorevaluationmethodbasedoncartesiancoordinatemeasurementmethod AT linjiachun researchoftoothprofileerrorevaluationmethodbasedoncartesiancoordinatemeasurementmethod |