Study on Load Distribution of Involute Spline Pair in Tooth Direction Used in Power Split

Taking two kinds of typical involute splines applied in the power split system as the research object,the theoretical analysis models of the load distribution factor in the tooth direction are established respectively,and the effects of load position,torque distribution and torsional rigidity of spl...

Full description

Saved in:
Bibliographic Details
Main Authors: Cheng Wang, Feihong Mao, Wei Hou, Peng Gui, Tiangang Zou
Format: Article
Language:zho
Published: Editorial Office of Journal of Mechanical Transmission 2020-12-01
Series:Jixie chuandong
Subjects:
Online Access:http://www.jxcd.net.cn/thesisDetails#10.16578/j.issn.1004.2539.2020.12.006
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841547194061029376
author Cheng Wang
Feihong Mao
Wei Hou
Peng Gui
Tiangang Zou
author_facet Cheng Wang
Feihong Mao
Wei Hou
Peng Gui
Tiangang Zou
author_sort Cheng Wang
collection DOAJ
description Taking two kinds of typical involute splines applied in the power split system as the research object,the theoretical analysis models of the load distribution factor in the tooth direction are established respectively,and the effects of load position,torque distribution and torsional rigidity of splines on the load distribution in the tooth direction are studied. The results show that,for the first kind of involute spline pair,with the increase of load distribution position and load distribution ratio,the maximum load distribution factor first decreases and then increases. There are optimal load position and optimal load distribution ratio to minimize the maximum load distribution factor,with the reduction ratio of 56.67% and 51.83% respectively. When the left torsional stiffness is 450×10<sup>6</sup> N/rad and the right torsional stiffness is 522×10<sup>6</sup> N/rad,the maximum load distribution factor reaches the minimum value of 2.08,and the maximum value increases by 31.8% compared with the minimum value. For the second involute spline pair,the maximum load distribution factor increases gradually with the increase of the left torque position,and the increase proportion is 14.36%,the influence of load distribution on the maximum load distribution factor is very small. With the increase of torsional rigidity,the maximum load distribution factor increases by 16.86%.
format Article
id doaj-art-31f3b0012e884049beceea44b31bfc95
institution Kabale University
issn 1004-2539
language zho
publishDate 2020-12-01
publisher Editorial Office of Journal of Mechanical Transmission
record_format Article
series Jixie chuandong
spelling doaj-art-31f3b0012e884049beceea44b31bfc952025-01-10T14:54:38ZzhoEditorial Office of Journal of Mechanical TransmissionJixie chuandong1004-25392020-12-014436425491681Study on Load Distribution of Involute Spline Pair in Tooth Direction Used in Power SplitCheng WangFeihong MaoWei HouPeng GuiTiangang ZouTaking two kinds of typical involute splines applied in the power split system as the research object,the theoretical analysis models of the load distribution factor in the tooth direction are established respectively,and the effects of load position,torque distribution and torsional rigidity of splines on the load distribution in the tooth direction are studied. The results show that,for the first kind of involute spline pair,with the increase of load distribution position and load distribution ratio,the maximum load distribution factor first decreases and then increases. There are optimal load position and optimal load distribution ratio to minimize the maximum load distribution factor,with the reduction ratio of 56.67% and 51.83% respectively. When the left torsional stiffness is 450×10<sup>6</sup> N/rad and the right torsional stiffness is 522×10<sup>6</sup> N/rad,the maximum load distribution factor reaches the minimum value of 2.08,and the maximum value increases by 31.8% compared with the minimum value. For the second involute spline pair,the maximum load distribution factor increases gradually with the increase of the left torque position,and the increase proportion is 14.36%,the influence of load distribution on the maximum load distribution factor is very small. With the increase of torsional rigidity,the maximum load distribution factor increases by 16.86%.http://www.jxcd.net.cn/thesisDetails#10.16578/j.issn.1004.2539.2020.12.006Involute splineTooth load distributionPower split
spellingShingle Cheng Wang
Feihong Mao
Wei Hou
Peng Gui
Tiangang Zou
Study on Load Distribution of Involute Spline Pair in Tooth Direction Used in Power Split
Jixie chuandong
Involute spline
Tooth load distribution
Power split
title Study on Load Distribution of Involute Spline Pair in Tooth Direction Used in Power Split
title_full Study on Load Distribution of Involute Spline Pair in Tooth Direction Used in Power Split
title_fullStr Study on Load Distribution of Involute Spline Pair in Tooth Direction Used in Power Split
title_full_unstemmed Study on Load Distribution of Involute Spline Pair in Tooth Direction Used in Power Split
title_short Study on Load Distribution of Involute Spline Pair in Tooth Direction Used in Power Split
title_sort study on load distribution of involute spline pair in tooth direction used in power split
topic Involute spline
Tooth load distribution
Power split
url http://www.jxcd.net.cn/thesisDetails#10.16578/j.issn.1004.2539.2020.12.006
work_keys_str_mv AT chengwang studyonloaddistributionofinvolutesplinepairintoothdirectionusedinpowersplit
AT feihongmao studyonloaddistributionofinvolutesplinepairintoothdirectionusedinpowersplit
AT weihou studyonloaddistributionofinvolutesplinepairintoothdirectionusedinpowersplit
AT penggui studyonloaddistributionofinvolutesplinepairintoothdirectionusedinpowersplit
AT tiangangzou studyonloaddistributionofinvolutesplinepairintoothdirectionusedinpowersplit