-
41
Comparison of joint position sense measured by inertial sensors embedded in portable digital devices with different masses
Published 2025-05-01“…In contrast, a significant increase in joint angle at the target position was noted when the smartphone was used. …”
Get full text
Article -
42
The impact of biomechanical analysis on sports performance of taekwondo athletes: a scoping review
Published 2025-06-01“…Results: The findings highlight that variables such as arm swing speed and knee joint angle are crucial for effective jumping techniques. …”
Get full text
Article -
43
Joints with angle dependent damping can help to reduce impact forces in robots
Published 2025-08-01Get full text
Article -
44
AI-enabled full-body dynamic avatar reconstruction using triboelectric smart clothing for metaverse applications
Published 2025-07-01“…Finally, leveraging Unity-3D, we achieve ultra-accurate dynamic 3D avatars with a joint angle error of <3.63° and demonstrate their effectiveness using VR fitness and entertainment applications, showing how they can offer users standardized yet engaging experiences.…”
Get full text
Article -
45
Designing, prototyping, and evaluating an assistive device for lower limb muscle stretching: With the participatory approach
Published 2025-12-01“…Results: For evaluating the device's ability for correct stretching, joint angle changes during the application of muscle stretch were considered. …”
Get full text
Article -
46
Empirical Validation of a Streamlined Three-Repetition Sit-to-Stand Protocol Using MAI Motion
Published 2025-05-01“…Primary measurements were the mean values of each joint angle and the coefficient of variation (CV). Statistical comparisons (including one way ANOVA followed by paired <i>t</i>-tests or non-parametric equivalents) determined whether differences in mean (DiM) values or CV existed between 3x and 5x. …”
Get full text
Article -
47
Steps to Facilitate the Use of Clinical Gait Analysis in Stroke Patients: The Validation of a Single 2D RGB Smartphone Video-Based System for Gait Analysis
Published 2024-12-01“…We evaluated the agreement for knee, hip, and ankle joint angle kinematics in the frontal and sagittal plane and spatiotemporal gait parameters between the two systems. …”
Get full text
Article -
48
The effect of body-conforming passive wearable device with knee flexion taping on dynamic knee stability
Published 2025-01-01“…In this research, 20 healthy women performed single leg drop (SLD) and step-up (SU) tests with and without muscle fatigue. Knee joint angle, muscle activation, metabolic cost, and blood flow were measured across FTPW, passive wearable devices without flexion taping (PW), and control shorts (Ctrl). …”
Get full text
Article -
49
Electrical Impedance Myography Quantifies Holding and Pushing During Isometric Muscle Contractions
Published 2025-01-01“…Results: Our data suggests systematic variations of EIM signals caused by holding a joint angle, pushing against a immobile lever, and changes due to applying repetitive contraction scenarios. …”
Get full text
Article -
50
Enhancing the Accuracy of Pedicle Screw Placement Using 3D-Printed Screw-Guiding Techniques in the Lumbosacral Region for Small Breed Dogs: A Cadaveric Study
Published 2024-12-01“…Group C exhibited significantly smaller deviations in entry point, exit point, angle α, and angular deviation than Group A. In Group B, only the exit-point deviation was significantly smaller than that in Group A. …”
Get full text
Article -
51
Comparison of Trunk and Hip Extensor Activation According to Various Applications of Elastic Bands During Nordic Hamstring Exercise
Published 2025-08-01“…However, compensatory movements, such as an increased hip joint angle, make optimal execution difficult. Assisted NHE (ANHE) using an elastic band facilitates controlled movement, maintains high hamstring activation, and allows intensity adjustments. …”
Article -
52
A new phenotyping method for root growth studies in compacted soil validated by GWAS in barley
Published 2025-07-01“…In uncompacted soil, only the primary root exhibits vertical gravitropic set-point angle while a variable number of embryonic seminal roots develop with a shallower growth angle. …”
Get full text
Article -
53
Presence of Pain Shows Greater Effect than Tendon Structural Alignment During Landing Dynamics
Published 2025-02-01“…Data included the Victorian Institute of Sport Assessment Patellar Tendon (VISA-P) questionnaire; patellar tendon ultrasound characterization tissue (UTC) scans, in order to identify groups with misaligned tendon fibers (MTF) or aligned tendon fibers (ATF); and biomechanical assessments for CMJ and TJT. The joint angle (JA) at the lower limb was measured at peak ground reaction force (peak_vGRF) and maximal knee flexion (max_KF). …”
Get full text
Article -
54
Major Gene with Polygene Inheritance Analysis of Prostrate Growth Habit in Hybrids of <i>Chrysanthemum yantaiense</i> × <i>C. indicum</i>
Published 2025-04-01“…Five traits related to prostrate growth habit in chrysanthemum were investigated including plant height (PH), crown width of the plant (CP), creeping index (CI), gravitropic set-point angle (GSA), and growth habit (GH). The major gene plus polygene mixed inheritance analysis was conducted on five traits across four generations over two years. …”
Get full text
Article -
55
Work related musculoskeletal stress among residents of internal medicine on cardiological wards in their daily working practice – a kinematic and ergonomic analysis
Published 2025-08-01“…For the data analysis, characteristic values of joint angle distributions (percentiles P05, P25, P50, P75, and P95) for the head, neck, and torso during predefined tasks were examined and evaluated in accordance with ergonomic standards. …”
Get full text
Article