501
Electrophoretic Deposition of Carbon Nanotubes over TiO2 Nanotubes: Evaluation of Surface Properties and Biocompatibility
Published 2014-01-01“…Titanium (Ti) is often used as an orthopedic and dental implant material due to its better mechanical properties, corrosion resistance, and excellent biocompatibility. …”
Get full text
Article -
502
Photocatalytic Degradation of Organic Dyes under Visible Light on N-Doped TiO2 Photocatalysts
Published 2012-01-01“…The photocatalytic activity of N-doped titanium dioxide, synthesized by direct hydrolysis of titanium tetraisopropoxide with ammonia, was evaluated by means of a batch photoreactor. …”
Get full text
Article -
503
A non-metallic PEEK topology optimization reconstruction implant for large mandibular continuity defects, validated using the MANDYBILATOR apparatus
Published 2025-01-01“…Abstract In cases of large mandibular continuity defects resulting from malignancy resection, the current standard of care involves using patient-specific/custom titanium reconstruction plates along with autogenous grafts (fibula, scapula, or iliac crest segments). …”
Get full text
Article -
504
The scope of application of additive technologies by the method of plasma surfacing in the manufacture of aircraft engines
Published 2024-11-01“…The obtained properties of heat-resistant nickel and titanium alloys are not inferior to blanks obtained by casting and forging methods. …”
Get full text
Article -
505
Finite element analysis of the influence of occlusal contact on maxillary All-on-4 immediate loading under different framework materials
Published 2024-12-01“…The cone beam CT data, crown, framework, abutment and implant data were used and the titanium, cobalt-chromium alloy, polyetheretherketone(PEEK) and resin framework materials were specified. …”
Get full text
Article -
506
Study of the corrosion behavior of cast Ti2AlNb alloy in HF–HNO3 solution
Published 2025-01-01Get full text
Article -
507
Efficacy of a Single Trapezoidal-Shaped 3-D Condylar Plate in the Osteosynthesis of Mandibular Condylar Fractures
Published 2024-12-01“…Under general anesthesia, the chosen patients underwent open reduction and fixation using three-dimensional titanium miniplates called trapezoidal condylar plates (TCPs). …”
Get full text
Article -
508
Enhanced strength and reduced elastic modulus of biomedical metastable β Ti–Nb alloy via intermediate phase transformation
Published 2025-03-01“…The high strength of biomedical titanium alloys is primarily attained through precipitation strengthening of the α phase. …”
Get full text
Article -
509
Laser Welded versus Resistance Spot Welded Bone Implants: Analysis of the Thermal Increase and Strength
Published 2014-01-01“…The first aim of this “ex vivo split mouth” study was to compare the thermal elevation during the welding process of titanium bars to titanium implants inserted in pig jaws by a thermal camera and two thermocouples. …”
Get full text
Article -
510
Marginal Discrepancy of Cast Copings to Abutments with Three Different Luting Agents
Published 2019-01-01“…Sixty-four analogs of CeraOne-type abutments (NACONIH code, Titanium Fix Implant Sytem SP, Brazil) were divided into four groups (n = 16). …”
Get full text
Article -
511
MUITI-OBJECTIVE OPTIMAZATION IN THE ELECTRICAL DISCHARGE MACHINING OF THE TA7 BASED ON BSO ALGORITHM
Published 2018-01-01“…The results show that the brainstorm algorithm can effectively obtain the best process parameters of TA7 titanium alloy EDM.…”
Get full text
Article -
512
MESOSCOPIC SCALE MINIMUM CUTTING THICKNESS MODEL AND ANALYSIS
Published 2022-01-01“…Aiming at the minimum cutting thickness existing in mesoscopic cutting process, the formation mechanism of the minimum cutting thickness was described, and the theoretical model of minimum cutting thickness based on tool edge radius and friction coefficient between workpiece and tool was proposed, and the cutting parameters were substituted into the theoretical model, and the minimum cutting thickness is calculated to be 2.3 μm. Taking Ti6 Al4 V titanium alloy as the research object, the 2 D cutting model of titanium alloy was established by using ABAQUS finite element software, and the simulation results show that the minimum cutting thickness is between 2 μm~3 μm, which verifies the correctness of the theoretical model of minimum cutting thickness. …”
Get full text
Article -
513
The Improved Photocatalytic Properties of Methylene Blue for V2O3/CNT/TiO2 Composite under Visible Light
Published 2010-01-01“…Multiwall carbon nanotube (MWCNT), vanadyl acetylacetonate (V(acac)3), and titanium n-butoxide (TNB) were used as carbon, vanadium oxide, and titanium oxide precursor to prepare V2O3/CNT/TiO2 composite. …”
Get full text
Article -
514
Synthesis and Kinetics of Generation of MMS/MFI Materials Prepared on the Basis of Ti-Aerosil
Published 2006-12-01“…Increasing HTP time was accompanied by the formation of a highly crystalline zeolite framework in the titanium-silica matrix which exhibited increasing microporosity accompanied by the destruction of the mesoporous framework.…”
Get full text
Article -
515
Optimization of S-N curve fitting based on neighborhood rough set reduction with improved firefly algorithm
Published 2023-04-01“…In order to reduce the S-N curve dispersion of titanium alloy welded joints and improve the prediction accuracy of fatigue life, a novel optimization method of S-N curve fitting based on neighborhood rough set reduction with improved firefly algorithm (IFANRSR) is proposed. …”
Get full text
Article -
516
Research Progress of Adsorption and Photocatalysis of Formaldehyde on TiO2/AC
Published 2021-01-01“…In this paper, the research progress of activated carbon and its modification, the photocatalytic principle and modification of titanium dioxide, and TiO2/AC materials are reviewed. …”
Get full text
Article -
517
Laser printing of certain pixels of graphene nanoribbons
Published 2024-06-01“…To provide the transfer, a target consisting of a transparent sapphire plate and an absorbing thin titanium film (500 nm thick) coated with a film consisting of graphene nanoribbons is irradiated with a KrF excimer laser (λ=248 nm, τ=20 ns). …”
Get full text
Article -
518
Déposition par Pulvé Risation Cathodique Radio Fréquence et Caracté Risation Électronique, Structurale et Optique de Couches Minces du Dioxyde de Titane
Published 2004-01-01“…Deposited titanium oxide thin films are used as optical protector films for several materials and as energy converters for solar cells. …”
Get full text
Article -
519
Preparation and Characterization of Antimony-Doped Tin Oxide Nanocrystallite Coatings on 316L Stainless Steel
Published 2021-01-01“…The study on the coatings containing antimony-dope tin oxide mostly has been done on titanium and its alloys for preparation of electrode materials. …”
Get full text
Article -
520
Thermal effects of ternary Casson nanofluid flow over a stretching sheet: An investigation of Thomson and Troian velocity slip
Published 2025-01-01“…The ternary nanofluid comprises three different nanoparticles, which include titanium dioxide (TiO2), copper (Cu), and silver (Ag), all being suspended in oil, which is the base fluid. …”
Get full text
Article