-
2841
Abnormal Grain Growth Mechanism in the Twin-Roller Cast Al-Fe-Si Alloy in the Annealing Process
Published 2020-01-01“…Abnormal grains of more than 15 mm in the nominal diameter were found to have formed on the surface of the billet. Scanning electronic microscopy observation, energy diffraction spectrum, microarea X-ray diffraction, and electronic backscattered diffraction analysis were performed to study this abnormal grain growth. …”
Get full text
Article -
2842
Co-treatment of industrial air streams using A.O.P. and adsorption processes
Published 2003-01-01“…Prior to adsorption/photocatalysis cyclic study, new TiO2 based catalysts were prepared by impregnating commercial zeolites in pellets form using a sol-gel technique. Scanning Electronic Microscopy observations linked to BET and adsorption equilibrium measurements of two VOC (1-butanol or BuOH and methyl-ethyl-ketone or MEK) showed that TiO2 happened to fix on the inert binder, without significant modification of support properties. …”
Get full text
Article -
2843
Experimental investigation of crack initiation and propagation in high- and gigacycle fatigue in titanium alloys by study of morphology of fracture
Published 2015-12-01“…Fracture surface analysis for cylindrical samples was carried out using optical and electronic microscopy method. High resolution profilometry (interferometerprofiler New View 5010) data of fracture surface roughness allowed us to estimate scale invariance (the Hurst exponent) and to establish the existence of two characteristic areas of damage localization (different values of the Hurst exponent). …”
Get full text
Article -
2844
Development of Solid Nanosystem for Delivery of Chlorhexidine with Increased Antimicrobial Activity and Decreased Cytotoxicity: Characterization and In Vitro and In Ovo Toxicologic...
Published 2025-01-01“…After the characterization of the CHX-NPS nanosystem through infrared spectroscopy and electronic microscopy, the in vitro results showed that the CHX antimicrobial efficacy was enhanced when delivered through a nanoscale system, with improved bioavailability and reduced toxicity when this was tested as the newly CHX-NPS nanosystem. …”
Get full text
Article -
2845
Experimental investigation of crack initiation and propagation in high- and gigacycle fatigue in titanium alloys by study of morphology of fracture
Published 2016-01-01“…Fracture surface analysis for cylindrical samples was carried out using optical and electronic microscopy method. High resolution profilometry (interferometerprofiler New View 5010) data of fracture surface roughness allowed us to estimate scale invariance (the Hurst exponent) and to establish the existence of two characteristic areas of damage localization (different values of the Hurst exponent). …”
Get full text
Article -
2846
Genotoxicity of Copper and Nickel Nanoparticles in Somatic Cells of Drosophila melanogaster
Published 2018-01-01“…Additionally, a complete physical characterization of NPs using transmission electronic microscopy (TEM), dynamic light scattering (DLS), and laser Doppler velocimetry (LDV) techniques was also performed. …”
Get full text
Article -
2847
Spatial Microstructural Ordering of Expansive Clay Minerals
Published 2018-01-01“…The clay microstructure was obtained using X-ray diffraction, and sweeping electronic microscopy. Physical characterization includes pH analysis. …”
Get full text
Article -
2848
Wear surface damage of a Stainless Steel EN 3358 aeronautical component subjected to sliding
Published 2013-01-01“…The present paper describes the different damage observed and the microstructure of the material, then are reported the results obtained from the characterization of the material of the samples by means of optical and electronic microscopy, carried out to define the mechanisms involved in the system seizure. …”
Get full text
Article -
2849
Wear surface damage of a Stainless Steel EN 3358 aeronautical component subjected to sliding
Published 2012-12-01“…The present paper describes the different damage observed and the microstructure of the material, then are reported the results obtained from the characterization of the material of the samples by means of optical and electronic microscopy, carried out to define the mechanisms involved in the system seizure. …”
Get full text
Article -
2850
Preparation and properties of alkali-activated slag-like powder paste
Published 2025-03-01“…Additionally, a series of analytical techniques, including X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FT-IR) and scanning electronic microscopy with energy dispersive spectroscopy (SEM-EDS), were used to explain the underlying reasons for the differences in macroscopic properties from a microscopic perspective. …”
Get full text
Article -
2851
Role of CO2 Laser on SBS between Dental Porcelain and Composite Resin Repair Process
Published 2023-01-01“…Additionally, three specimens were used in scanning electronic microscopy and energy-dispersive spectroscopy tests. …”
Get full text
Article -
2852
Exemplarily view on selected fluorescence textile products
Published 2023-02-01“…Further, scanning electronic microscopy (SEM) and Fourier Transform infrared (FT-IR) spectroscopy are used. …”
Get full text
Article -
2853
Effect of preparation method in the properties of iron oxide catalysts for fenton reaction
Published 2020-12-01“…The solids were prepared by precipitation, complexation, combustion, and decomposition and characterized by Fourier transform infrared spectroscopy, X-ray diffraction, scanning electronic microscopy, energy dispersive X-ray spectroscopy, specific surface area measurement and were evaluated for methylene blue removal. …”
Get full text
Article -
2854
Tensile Fracture Behavior of Corroded Pipelines: Part 2—Numerical Simulation Based on Monte Carlo Method
Published 2020-01-01“…Inspired by the surface topology by scanning electronic microscopy (SEM) and the scattered distribution of test data, a computational procedure based on the Monte Carlo simulation method was developed in this paper to understand the randomness of the crack propagation process and the performance degradation mechanism of the corroded pipelines. …”
Get full text
Article -
2855
Failure of cargo aileron’s actuator
Published 2014-10-01“…The failure analysis was performed by means of optical, metallographic, digital and electronic microscopy. The collected evidences showed a multiple initiation fracture mechanism. …”
Get full text
Article -
2856
Cutibacterium acnes biofilm formation is influenced by bone microenvironment, implant surfaces and bacterial internalization
Published 2024-07-01“…Methods In this study, we compared the biofilm formation of C. acnes PJI-related strains and non-PJI-related strains on plastic support and textured titanium alloy by (i) counting adherent and viable bacteria, (ii) confocal scanning electronic microscopy observations after biofilm matrix labeling and (iii) RT-qPCR experiments. …”
Get full text
Article -
2857
Determination of the Hydration Damage Instability Period in a Shale Borehole Wall and Its Application to a Fuling Shale Gas Reservoir in China
Published 2019-01-01“…In this study, the stratigraphic stress characteristics of the Fuling Shale Gas Field were initially predicted, and the shale sample phase composition and development of bedding and microcracks were analyzed using X-ray diffraction and scanning electronic microscopy. The main driving potential difference function between the drilling fluid and shale was analyzed, and a radial adsorption diffusion model of the shale plane was established. …”
Get full text
Article -
2858
Incorporation of kiwifruit peel improved the property of carboxymethyl cellulose-gum Arabic active film and its effects on the quality of beef sausages
Published 2025-02-01“…Consequently, CG-KPE films demonstrated a superior antimicrobial effect on Gram-positive (Staphylococcus aureus and Bacillus cereus) and Gram-negative (Escherichia coli) bacteria and antioxidant efficacy compared to CG-CT films. The scanning electronic microscopy (SEM) of CG-KPE films revealed an enhanced micrograph. …”
Get full text
Article -
2859
Surface prereacted glass-ionomer particles incorporated into resin composites promote biocompatibility for restoration of subgingival dental defects
Published 2025-04-01“…The microstructure and elemental distribution were characterized by scanning electronic microscopy and energy-dispersive spectroscopy. …”
Get full text
Article -
2860
Crack of a helicopter main rotor actuator attachment: failure analysis and lessons learned
Published 2013-09-01“…Fracture surfaces were examined by optical and electronic microscopy in order to determine the main morphological features and consequently to trace the origin of failure mechanism and causes. …”
Get full text
Article