Showing 141 - 160 results of 629 for search '"The Outlet"', query time: 0.05s Refine Results
  1. 141

    Influence of Coal Caving Time and Tail Beam Swing Angle on the Evolution of the Coal Gangue Boundary Line during Top Coal Caving by Qingliang Zeng, Yanpeng Zhu, Yang Yang, Zhe Li, Lirong Wan

    Published 2022-01-01
    “…At the same caving time, the position of the coal gangue boundary will be closer to the coal caving outlet, which leads to excessive mixing of coal and gangue. …”
    Get full text
    Article
  2. 142

    Influence of Blade Profiles on Plastic Centrifugal Pump Performance by Hui Zhang, Lingfeng Tang, Yongtao Zhao

    Published 2020-01-01
    “…The impeller inlet and outlet diameters (D1 and D2) and impeller inlet and outlet installation angles (β1 and β2) were taken as control variables, and the total power loss and the minimum NPSHr of the pump were taken as the objective functions. …”
    Get full text
    Article
  3. 143

    An Extension of Taylor’s φ-Circle Method and Some Stability Charts for Submerged Slopes by Ping Li, Luanhua Dong, Xiaowen Gao, Tonglu Li, Xiaokun Hou

    Published 2020-01-01
    “…Taylor derived equations in two cases separately, namely, (i) the outlet of the critical failure surface is at the slope toe and (ii) the outlet of the failure surfaces is not at the slope toe. …”
    Get full text
    Article
  4. 144

    Bubble Flow Analysis of High Speed Cylindrical Roller Bearing under Fluid-Solid Thermal Coupling by Li Cui, Wenxia Wang, Zhang Yanlei

    Published 2017-01-01
    “…An increase of air content in the oil produces a lower pressure at the bearing outlet while the exit fluid velocity increases. When fluid-solid thermal coupling effect is considered, velocity and pressure at outlet of the bearing both become larger, while temperature of bearing is lower than that without coupling. …”
    Get full text
    Article
  5. 145

    Sensitivity Evaluation of AP1000 Nuclear Power Plant Best Estimation Model by Hao Shi, Qi Cai, Yuqing Chen

    Published 2017-01-01
    “…The feedwater temperature is a sensitive factor to the Steam Generator (SG) outlet temperature and the Steam Generator outlet pressure. …”
    Get full text
    Article
  6. 146

    Performance Assessment of Sintered Metal Fiber Filters in Fluid Catalytic Cracking Unit by Liang Yang, Zhongli Ji, Qiaoqi Xu, Hao Li

    Published 2014-01-01
    “…The inlet volume median diameter and the outlet volume median diameter of the particle are about 1 μm and 2.2 μm, respectively. …”
    Get full text
    Article
  7. 147

    The Effects of Warm Air Heater on the Dispersion and Deposition of Particles in an Enclosed Environment by Xi Chen, Jiangyi Li, Xiangxiang Zhang, Shuai Liu, Kapnang Franky, Wanwan Li, Wenfeng Bi

    Published 2021-03-01
    “…Furthermore, the particles’ decay rate loss coefficients increased with the heater’s output power and the particles’ proximity tothe heater’s air outlet but were also influenced by the direction of the warm air flow.…”
    Get full text
    Article
  8. 148

    Improve Efficiency of Photovoltaic/Thermal Systems using Porous Materials: An Experimental Study by H. Farzan

    Published 2025-07-01
    “…The acquired results revealed that using steel wool reduces the PV temperature by 9.9 oC and increases the outlet temperature by 4.41 oC at the air flow rate of 0.17 kg/s. …”
    Get full text
    Article
  9. 149

    Numerical Simulation of Pollutant Transport in Fractured Vuggy Porous Karstic Aquifers by Xiaolin Fan, Shuyu Sun, Wei Wei, Jisheng Kou

    Published 2011-01-01
    “…The temporal multiscale phenomena of the effluent concentration on the outlet are observed. The results show how the different distribution of the vugs and the fractures impacts on the contaminant transport and the effluent concentration on the outlet. …”
    Get full text
    Article
  10. 150

    Determination of susceptible areas to water erosion in the Hervi watershed by Mohammad Javad vahidi, Rasoul Mirabbasi

    Published 2019-06-01
    “…Then, status of erosion and sediment in watersheds and sub-watersheds was studied using Hjulstrom curve (based on the mean diameter size of sediment particles and the maximum potential velocity of outlet), and was comparatively classified in term of erodibility. …”
    Get full text
    Article
  11. 151

    Flow Pattern Analysis and Performance Improvement of Regenerative Flow Pump Using Blade Geometry Modification by J. Nejadrajabali, A. Riasi, S. A. Nourbakhsh

    Published 2016-01-01
    “…The first type has symmetric angle blades with identical inlet/outlet angles of ±10°, ±30°, and ±50° and the second group has nonsymmetric angle blades in which the inlet angle was set to 0° and six different angles of ±10°, ±30°, and ±50° were designed for the outlet of the blades. …”
    Get full text
    Article
  12. 152

    Modelling the Evaporation Rate in an Impingement Jet Dryer with Multiple Nozzles by Anna-Lena Ljung, L. Robin Andersson, Anders G. Andersson, T. Staffan Lundström, Mats Eriksson

    Published 2017-01-01
    “…Furthermore, the humidity of the inlet air, as determined from the degree of recirculating outlet air, has a strong effect on the water evaporation rate. …”
    Get full text
    Article
  13. 153
  14. 154

    Numerical Study of the Compressible Air Flow Through a Two-output Fluidic Oscillator by A. Lakehal, M. Aksouh, A. Medelfef

    Published 2025-02-01
    “…The results demonstrate that the outlet velocity is influenced by the inlet conditions as well as the system's geometry. …”
    Get full text
    Article
  15. 155

    Storm Water Control Effect of Low Impact Development Facilities Based on SWMM: A Case Study of Yaohu Campus of Nanchang Institute of Technology by ZHANG Jingrong, LIU Weilin, WAN Yifan, LIU Jianwu, ZHONG Jinghao, LIU Lina

    Published 2024-06-01
    “…The results indicate that :①The storm water simulation results of SWMM in the study area are in good agreement with the actual situation after parameter adjustment, demonstrating good applicability; ② LID facilities have a good control effect on rainfall runoff; ③ The construction of LID facilities can better reduce the peak flow of the drainage outlet in the study area. With the reduction of the rainstorm return period, the reduction rate basically remains unchanged, and the delay effect on the peak moment of the drainage outlet is enhanced; ④ After the construction of LID facilities, the runoff at the peak moment of each subcatchment area in the study area is reduced by about 0.02 m<sup>3</sup>/s, and the runoff at the peak moment of areas with large runoff such as dormitories and libraries can be reduced to about 0.05 m<sup>3</sup>/s, reducing the impact of rainfall runoff on the travel of teachers and students.…”
    Get full text
    Article
  16. 156

    Optimization of Highly Porous Mannitol Preparation using Ammonium bicarbonate and Citric acid as Templating Agents with Spray Drying Technique by Nindya Kusumorini, Adhyatmika

    Published 2023-12-01
    “…The results show that the ratio of D-mannitol to ammonium bicarbonate 10:5 w/w% with water solvent temperature of 30 oC, spray drying inlet temperature of 120 oC, and spray drying outlet temperature of 70 oC, resulting in the highest porosity, surface area, and pore volume. …”
    Get full text
    Article
  17. 157

    Regulation of Temperature on Multitrays in an Indirect Solar Dryer (ISD) with Energy Storage and Three Airflow Modes by G. B. Tchaya, E. Tchoffo Houdji, J. H Tchami, C. Kapseu, M. Kamta

    Published 2021-01-01
    “…Irradiance and humidity have also been recorded. The model of outlet temperature with energy storage was given by using heat transfer equations. …”
    Get full text
    Article
  18. 158

    Study on Microscopic Water Flooding in Porous Carbonate Reservoirs by Numerical Simulation by Tao Yu, Baozhu Li, Mingqiang Hao, Benbiao Song

    Published 2022-01-01
    “…Changing the position of water inlet and the produced fluid outlet results in better recovery since the remaining oil near the new inlet and outlet can be effectively produced.…”
    Get full text
    Article
  19. 159

    Assessment of the quality of water resources for drinking, agriculture and industry in karstic aquifer of Roein Esfarayen basin of North khorasan province by Mohammad Motamedi Rad, Leila Goli Mokhtari, Shahram Bahrami, Mohammad ali zanganeh asadi

    Published 2021-09-01
    “…The WQI index is also indicative of the quality of all samples taken in drinking water, and only the surface water of the basin outlet whose WQI is above 50 is in good condition. …”
    Get full text
    Article
  20. 160

    Optimization Design and Internal Flow Field Study of Open-Design Vortex Pump by Xiongfa Gao, Weidong Shi, Ruijie Zhao, Ting Zhao, Hongfei Wang

    Published 2021-01-01
    “…The selected main factors included impeller outer diameter (D2), impeller outlet width (b2), outlet setting angle of impeller (β2), and inlet setting angle of impeller (β1), and the nine types of impellers were coded according to orthogonal table. …”
    Get full text
    Article