Showing 1,061 - 1,080 results of 2,847 for search '"Microscope', query time: 0.07s Refine Results
  1. 1061

    In Vivo Inflammatory Effects of Ceria Nanoparticles on CD-1 Mouse: Evaluation by Hematological, Histological, and TEM Analysis by Anna Poma, Anna Maria Ragnelli, Joaquin de Lapuente, David Ramos, Miquel Borras, Pierpaolo Aimola, Mario Di Gioacchino, Sandro Santucci, Laura De Marzi

    Published 2014-01-01
    “…Anyhow, performing in vivo evaluations on CD-1 mouse systems, we demonstrate that it is even not correct to assert that ceria NPs are harmless for living systems as they can induce status of inflammation, revealed by hematological-chemical-clinical assays as well as histological and TEM microscope observations. TEM analysis showed the presence of NPs in alveolar macrophages. …”
    Get full text
    Article
  2. 1062

    Effect of temperature and time on purity, morphology and phase transformations of silica from rice husk by Md. Tariqul Islam, Md. Faruk Hossen, Md. Kudrat-E-Zahan, Md. Ali Asraf, C.M. Zakaria, Hayatullah, Md Shohel Rana

    Published 2025-04-01
    “…The surface morphological structure of rice husk ash, which is observed by Scanning Electronic Microscope (SEM) result, confirms that the highest amount of silica content is in the outer layer of the husk, which is in the amorphous form. …”
    Get full text
    Article
  3. 1063

    The particle size distribution (PSD) as criteria for comparison of silver powders obtained by different methods of synthesis and by conditions of electrolysis by Avramović Lj., Bugarin M., Milanović D., Conić V., Pavlović M.M., Vuković M., Nikolić N.D.

    Published 2018-01-01
    “…Silver powders produced by both electrochemical (galvanostatic (DC) and potentiostatic (POT) regimes of electrolysis) and chemical processes were examined by scanning electron microscope, and particle size distribution (PSD) of the obtained particles was done. …”
    Get full text
    Article
  4. 1064

    Effect of laboratory aging on the performance of asphalt mixture containing high RAP content with the rejuvenator-loaded fiber by Yuxuan Sun, Fan Zhang, Augusto Cannone Falchetto, Di Wang

    Published 2025-07-01
    “…Finally, an Environmental Scanning Electron Microscope (ESEM) was utilized to analyze the distribution and action mechanisms of rejuvenator-loaded fibers within the asphalt mixture. …”
    Get full text
    Article
  5. 1065
  6. 1066

    Effect of Epoxy Resin Emulsion on the Mechanical Properties of Oil Well Cement-Based Composites by Miao He, Jianjian Song, Mingbiao Xu, Lei He, Peng Xu

    Published 2020-01-01
    “…Epoxy resin emulsion was added to oil well cement and its workability and mechanical properties were studied, the stress-strain behavior of cement samples was evaluated, and the microstructure was observed by scanning electron microscope (SEM) and X-ray diffraction (XRD). The results show the epoxy resin emulsion used in oil well cement will affect the fluidity, but the rheological property of cement slurry with different content of resin meets the construction requirements. …”
    Get full text
    Article
  7. 1067

    Stereomicroscopic Evaluation of Sealing Ability of Three Different Furcal Perforation Repair Materials: An In vitro Study by Sriparna De, N Sathyajith Naik, Shivangi Sharma, Pallavi Vashisth, Rasleen Dua, Priya Maheshwari

    Published 2024-12-01
    “…The teeth were sectioned longitudinally and the linear dye penetration was measured using a stereo-microscope. Results: The one-way analysis of variance (ANOVA) revealed a statistically significant difference among the groups (F = 16.15, P < 0.001). …”
    Get full text
    Article
  8. 1068

    ParasitoBank dataset for diagnosing intestinal parasitism: Helminths and protozoa in coprological samplesMendeley Data by Jader Alejandro Muñoz Galindez, Luis Reinel Vásquez Arteaga, Rubiel Vargas Cañas

    Published 2025-02-01
    “…For this reason, a dataset named “ParasitoBank” was created, containing 779 images of the visual field of fresh stool samples analysed under a microscope using the serial coprological technique. …”
    Get full text
    Article
  9. 1069

    Improvement of Microstructure and Properties of Q235 Steel by Iron-Based Laser Cladding Coating by Yuanwei He, Yu Gu, Li Tang, Hu Wang

    Published 2022-01-01
    “…The microstructure of the cladding coating was explored using an Olympus optical microscope and SEM. The results showed that the average hardness of sample 2 and sample 3 was 6.42% and 19.84% higher than that of sample 1. …”
    Get full text
    Article
  10. 1070

    Synthesis and Characterisation of Copper(II) Complexes with Tridentate NNO Functionalized Ligand: Density Function Theory Study, DNA Binding Mechanism, Optical Properties, and Biol... by Madhumita Hazra, Tanushree Dolai, Akhil Pandey, Subrata Kumar Dey, Animesh Patra

    Published 2014-01-01
    “…The optical absorption and fluorescence emission properties of microwires were characterized by fluorescence microscope. From a spectroscopic viewpoint, all compounds strongly emit green light in the solid state. …”
    Get full text
    Article
  11. 1071

    Kingdom Come by Ballard: The Stricken City by Nicole Terrien

    Published 2009-12-01
    “…L’esthétique de la violence ne définit pas seulement l’ordre politique dénoncé, mais caractérise aussi le mode opératoire du roman qui, à travers les mises en scènes de moments disjoints et le choix d’un vocabulaire décalé, oblige le lecteur à s’interroger sur l’espace dans lequel il vit. Tel un microscope, le roman donne à voir l’espace de la banlieue comme un gigantesque "incubateur" de nouveaux pathogènes, observés à dessein par les pouvoirs politiques qui se croient à l’abri de la contagion. …”
    Get full text
    Article
  12. 1072

    Development of Semi-Static Steam Process for the Production of Sludge-Based Adsorbents by Yehya A. El-Sayed, Kevin F. Loughlin, Saeed ur Rehman, Dana Abouelnasr, Isam Al-Zubaidy

    Published 2014-04-01
    “…The surface chemistry for the SBA samples is characterized using Boehm titrations, pH measurement, ash content and scanning electron microscope integrated with energy-dispersive spectroscopy (EDAX). …”
    Get full text
    Article
  13. 1073

    Deteksi Pencemaran Mikroplastik pada Air Lindi di TPA Piyungan Yogyakarta Indonesia by Inggita Utami, Agustina Agustina

    Published 2022-05-01
    “…Identification of microplastics was carried out visually using a microscope, while the identification of polymer types was determined by the Fourier-transform infrared streptoscopy test. …”
    Get full text
    Article
  14. 1074

    Experimental Study on Shear Characteristics of Coal Samples in Different Water-Bearing States by Yang Wu, Lujun Wang, Baoyang Wu, Ze Xia

    Published 2024-01-01
    “…Additionally, scanning electron microscope analysis revealed significant changes in the microstructure of coal samples under different moisture states: as the moisture content and dry-saturation cycles increase, the microstructure of the coal samples gradually transforms from orderly and compact to disordered and murky, elucidating the mechanism by which moisture weakens the mechanical properties of the coal samples. …”
    Get full text
    Article
  15. 1075

    Visualizing and quantifying biomineral preservation in fossil vertebrate dental remains by Matthew B. Cowen, Marc de Rafélis, Loïc Ségalen, Benjamin P. Kear, Maïtena Dumont, Živilė Žigaitė

    Published 2025-01-01
    “…We present visual comparisons of elemental compositions in fish and plesiosaur dental remains ranging in age from Silurian to Cretaceous, based on a combination of micro-scale optical cathodoluminescence (CL) observations (optical images and scanning electron microscope) with in-situ minor, trace and rare earth element (REE) compositions (EDS, maps and REE profiles), as a tool for assessing diagenetic processes and biomineral preservation during fossilization of vertebrate dental apatite. …”
    Get full text
    Article
  16. 1076

    Improvement of Hydrophilicity for Polyamide Composite Membrane by Incorporation of Graphene Oxide-Titanium Dioxide Nanoparticles by Thu Hong Anh Ngo, Chau Thi Minh Nguyen, Khai Dinh Do, Quan Xuan Duong, Nghia Hieu Tran, Hoan Thi Vuong Nguyen, Dung Thi Tran

    Published 2020-01-01
    “…Membrane surface properties were determined through scanning electron microscope (SEM) images and Fourier transform infrared-attenuated total reflectance (FTIR-ATR) spectroscopy. …”
    Get full text
    Article
  17. 1077

    Fracture resistance and mode of failure of modified Polyether-ether-ketone versus lithium disilicate endocrowns by Mohamed G. A. Kharboush, Hesham I. Othman, Mohamed F. Aldamaty, Ahmed M. L. Alameldin

    Published 2025-01-01
    “…The failure mode was evaluated by inspecting fractured surfaces using a Stereomicroscope and further examined by a Scanning Electron Microscope (SEM) amongst both groups. Results A statistically significant variation in fracture resistance was recorded with a mean load of (2762.96 ± 216.15 N) for modified PEEK and (2175.91 ± 267.72 N) for lithium disilicate glass–ceramic endocrowns. …”
    Get full text
    Article
  18. 1078

    Modification of Mechanical Properties of Ti–6Al–4V Using L-PBF for Anatomical Plates by Soumyabrata Basak, Sang-Hun Lee, Jeong-Rim Lee, Dong-Hyun Kim, Jeong Hun Lee, Myunghwan Byun, Dong-Hyun Kim

    Published 2025-01-01
    “…This study thoroughly examines the microstructural evolution and its role in enhancing the mechanical properties of clavicle bone plates under sub-β-transus heat treatment for medical application. Scanning electron microscope (SEM) images of the as-built specimens reveal a dense formation of a hard α’ hcp martensite structure, which decomposes during annealing at 650 °C and ultimately transforms into an α + β lamellar structure at 950 °C. …”
    Get full text
    Article
  19. 1079

    Gambaran Jumlah dan Hitung Jenis Leukosit Ayam Petelur yang diinfeksi L2 Toxocara Cati by Diyah Ayu Candra, Nunuk Dyah Retno Lastuti, Nove Hidayati, Kusnoto Kusnoto, Poedji Hastutiek, Retno Bijanti

    Published 2020-06-01
    “…Leukocyte value was determined by improve neubauer and differential counting stained with Wright's stain then determined using microscope 1000x. The data was analyzed by Anova Factorial and then continued by BNJ Test at 5%. …”
    Get full text
    Article
  20. 1080

    Tackling somatic DNA contamination in sperm epigenetic studies by Anamika Kumari, Anamika Kumari, Rajender Singh, Rajender Singh

    Published 2025-02-01
    “…We have put together a comprehensive plan including evaluation under a microscope, SCLB treatment, inclusion of CpG biomarkers for sample quality evaluation, and applying a 15% cut off at the time of data analysis to completely eliminate the influence of somatic DNA contamination in sperm epigenetic studies. …”
    Get full text
    Article