Showing 481 - 500 results of 2,847 for search '"Microscope', query time: 0.06s Refine Results
  1. 481

    Influence of dipping time on cracking during bending of hot dip galvanized coatings with Sn and Ti contents by V. Di Cocco, L. Zortea

    Published 2013-04-01
    “…Longitudinal sections of bended specimens were observed by means of a LOM (Light Optical Microscope): main damage micromechanisms were identified as longitudinal and radial cracks.…”
    Get full text
    Article
  2. 482

    Combining Dynamic and Static Robotic Telepathology: A Report on 184 Consecutive Cases of Frozen Sections, Histology and Cytology by Vincenzo Della Mea, Palmina Cataldi, Barbara Pertoldi, Carlo A. Beltrami

    Published 2000-01-01
    “…The system provides static/dynamic features and the remote control of a robotized microscope over 4 ISDN lines. For evaluation purposes, 184 consecutive cases of frozen sections (60), gastrointestinal pathology (64), and urinary cytology (60) have been diagnosed at a distance using the system, and the telediagnosis obtained in this way has been compared with the traditional microscopic diagnosis. …”
    Get full text
    Article
  3. 483

    Research on Altered Rock at a Hydropower StationBased on Triaxial Unloading Test by LI Wancai, DENG Hui, ZHANG Qiyuan, LU Bifeng, HAO Hao, LI Anrun

    Published 2020-01-01
    “…In order to study the effects of water on the deformation and strength of the altered rock during unloading, this paper obtains the micro-structure and mineral distribution of the altered rock at the right dam abutment of a hydropower station in southwest China by SEM (scanning electron microscope), then analyzes and discusses the influences of water in different stress paths on the stress-strain curves, deformation characteristics and strength characteristics of altered rock through triaxial loading and unloading tests of rock samples under natural state and saturated state. …”
    Get full text
    Article
  4. 484

    MONITORING OF FLANK WEAR AND DAMAGE ON TURNING CUTTING TOOLS BY IMAGE PROCESSING by Joseph Kalil Khoury Junior, John Kenneth Schueller, Francisco de Assis Carvalho Pinto, Geice Paula Villibor

    Published 2020-06-01
    “…Consequently, 94.3% to identify between worn and broken insert and 0.04 mm mistake in measurement of flank wear width compared with microscope. …”
    Get full text
    Article
  5. 485

    EFFECT OF SURFACE ROUGHNESS ON FATIGUE PROPERTY OF TC4 TITANIUM ALLOY BY SELECTIVE LASER MELTING by DONG DengKe, CHEN An, LI XiaoFei, ZHANG HaiYing

    Published 2020-01-01
    “…The fatigue fractography is observed by scanning electron microscope to find the reason for surface roughness modification. …”
    Get full text
    Article
  6. 486

    The study of internal structure of woven glass and carbon fiber reinforced composite materials with embedded fiber-optic sensors by Grigorii Serovaev, Natalia Kosheleva

    Published 2020-01-01
    “…Analysis of the internal structure of the studied materials with 2´2 twill weave style was carried out using a digital microscope. In addition, the reflected optical signal from the Bragg gratings after being embedded into the composite material is analyzed.…”
    Get full text
    Article
  7. 487

    Plasticity, Swell-Shrink, and Microstructure of Phosphogypsum Admixed Lime Stabilized Expansive Soil by Jijo James, P. Kasinatha Pandian

    Published 2016-01-01
    “…The samples were also subjected to a microstructural study by means of scanning electron microscope. Addition of PG to lime resulted in improvement in the plasticity and swell-shrink characteristics. …”
    Get full text
    Article
  8. 488

    The Preparation and Characterization of Chitosan / Poly (Vinyl Alcohol) Blended Films by Esam A. El-Hefian, Mohamed Mahmoud Nasef, Abdul Hamid Yahaya

    Published 2010-01-01
    “…The chemical structure and the morphology of the obtained blend films were investigated using FTIR and field emission scanning electron microscope (FESEM). The thermal stability of the blend films were also studied using thermal gravimetric analysis (TGA). …”
    Get full text
    Article
  9. 489

    Nanoclustering in Silicon Induced by Oxygen Ions Implanted by D. Manno, A. Serra, E. Filippo, M. Rossi, G. Quarta, L. Maruccio, L. Calcagnile

    Published 2011-11-01
    “…The topographic images, obtained by scanning tunnelling microscope showed that the surface is covered with a dense array of tetragonal nanostructures oriented with respect to the substrate. …”
    Get full text
    Article
  10. 490

    Current Experiences with Internet Telepathology and Possible Evolution in the Next Generation of Internet Services by V. Della Mea, C. A. Beltrami

    Published 2000-01-01
    “…They may be listed as follows: (a) teleconsultation via multimedia e‐mail; (b) teleconsultation via web‐based tools; (c) distant education by means of World Wide Web; (d) virtual microscope management through Web and Java interfaces; (e) real‐time consultations through Internet‐based videoconferencing. …”
    Get full text
    Article
  11. 491

    Performance Characteristic of Cold Recycled Mixture with Asphalt Emulsion and Chemical Additives by Shaowen Du

    Published 2015-01-01
    “…To better understand its performance characteristic, the microstructure images of the recycled mixture were observed by environmental scanning electron microscope (ESEM). Test results demonstrate that the performance improvement of the emulsion recycled mixture depends on the types and content of chemical additives. …”
    Get full text
    Article
  12. 492

    Change of the structure of the surface of galvanic coatings under exposure to cold air plasma by A. G. Anisovich, I. I. Filatova, S. V. Goncharik, V. F. Gologan, Zh. I. Bobanova

    Published 2019-08-01
    “…At research in an optical microscope changes of structure of a surface are not established. …”
    Get full text
    Article
  13. 493

    Research on the Fatigue Performance of TC6 Compressor Blade under the CCF Effect by Zhang Yakui, Guo Shuxiang

    Published 2018-01-01
    “…Fatigue source characteristics and CCF fracture appearance were observed and analyzed using a scanning electron microscope (SEM).…”
    Get full text
    Article
  14. 494

    Study on the Cotton Fabrics with Photoinduced Reversibly Switchable Wettability by Caining Zhang, Xuman Wang

    Published 2023-01-01
    “…The surface morphology of the fabric was observed by scanning electron microscope (SEM). The wettability of the surface was tested under UV illumination and after storage in the dark. …”
    Get full text
    Article
  15. 495

    Cell growth monitoring in a tetrapolar electrode configuration by Singh Jagbir, Khambete Niranjan D.

    Published 2024-07-01
    “…The results demonstrated an initial increase in impedance corresponding with the cell growth phase, followed by a decrease during the cell death (apoptosis) phase, as confirmed by microscope images. Overall, the results show that our method to monitor cell growth using tetrapolar electrodes is promising and can be further refined for related applications.…”
    Get full text
    Article
  16. 496

    Fatigue crack tip damaging micromechanisms in a ferritic-pearlitic ductile cast iron by Francesco Iacoviello, Vittorio Di Cocco, Mauro Cavallini

    Published 2015-06-01
    “…In this work, fatigue crack tip damaging micromechanisms in a ferritic-pearlitic DCI were investigated by means of scanning electron microscope observations performed on a lateral surface of Compact Type (CT) specimens during the fatigue crack propagation test (step by step procedure), performed according to the “load shedding procedure”. …”
    Get full text
    Article
  17. 497

    The evaluation of biofilm production by streptococcus equi zooepidemicus isolates by Bilal Osamah Mohammed Mohammed, Uçkun Sait Uçan

    Published 2020-12-01
    “…The biofilm production was confirmed and the biofilm layers were detected by using the SEM microscope.<p> <b>Conclusion: </b>Equine clinicians in this Country should be aware of that Streptococcus equi zooepidemicus isolates are capable of forming biofilm in vitro.…”
    Get full text
    Article
  18. 498

    Electrodeposition and Corrosion Resistance Properties of Zn-Ni/TiO2 Nano composite Coatings by B. M. Praveen, T. V. Venkatesha

    Published 2011-01-01
    “…Scanning electron microscope images and X-ray diffraction patterns of coating revealed its fine-grain nature. …”
    Get full text
    Article
  19. 499

    Mechanism of crack branching in the fatigue crack growth path of 2324-T39 Aluminium alloy by Lu Songsong, Bao Rui, Zhang Ting, Fei Binjun

    Published 2016-01-01
    “…The crack paths were observed with optical microscope and in-situ SEM. Finite element crack tip simulation was performed to investigate the relationship between plastic zone size and the location of the secondary crack. …”
    Get full text
    Article
  20. 500

    Ternary invariant point at 374°C in the three phase region AlSb-Al-Zn inside the Al-Sb-Zn ternary system by Klančnik G., Medved J.

    Published 2011-01-01
    “…Al-Sb-Zn ternary system was investigated in the three phase region Al-AlSb-Zn, using differential thermal analysis (DTA), differential scanning calorimetry (DSC) and scanning electron microscope equipped with energy dispersive spectrometer (SEM-EDS). …”
    Get full text
    Article