The role and mechanisms of intraocular infusion during microinvasive guillotine and ultrasonic vitrectomy

<p> B.M. Aznabaev<sup>1,2</sup>, T.R. Mukhamadeev<sup>1,2</sup>, T.I. Dibaev<sup>1,2</sup>, T.N. Ismagilov<sup>1,2</sup> </p> <p> <sup>1</sup>Bashkir State Medical University, Ufa, Russian Federation </p> <p>...

Full description

Saved in:
Bibliographic Details
Main Authors: B.M. Aznabaev, T.R. Mukhamadeev, T.I. Dibaev, T.N. Ismagilov
Format: Article
Language:Russian
Published: Prime-Media 2023-03-01
Series:РМЖ "Клиническая офтальмология"
Online Access:http://clinopht.com/upload/iblock/56e/dxoy0qg02oia72r62cuoftj07qbxoym6.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841526923731140608
author B.M. Aznabaev
T.R. Mukhamadeev
T.I. Dibaev
T.N. Ismagilov
author_facet B.M. Aznabaev
T.R. Mukhamadeev
T.I. Dibaev
T.N. Ismagilov
author_sort B.M. Aznabaev
collection DOAJ
description <p> B.M. Aznabaev<sup>1,2</sup>, T.R. Mukhamadeev<sup>1,2</sup>, T.I. Dibaev<sup>1,2</sup>, T.N. Ismagilov<sup>1,2</sup> </p> <p> <sup>1</sup>Bashkir State Medical University, Ufa, Russian Federation </p> <p> <sup>2</sup>CJSC Optimedservis, Ufa, Russian Federation </p> <p> <br> </p> <p> Maintaining tone of the eyeball and stable intraocular pressure (IOP) during vitrectomy is an important issue associated with the safety of intraocular structures. As the vitreous body is removed, it is gradually replaced with a balanced salt solution, which leads to a decrease in viscosity of the vitreous chamber content and may contribute to changes of the hydrodynamic parameters during surgical procedures. Thus, it is necessary to ensure controlled operation and coordination of the infusion and aspiration modules used in the microsurgical system. Commonly, the imbalance between the aqueous humor inflow and outflow during vitrectomy may cause either a decrease or increase in IOP. The gravity infusion surgical systems cannot compensate for sudden changes in the hydrodynamic parameters during eye surgery, and, as a result, significant fluctuations in IOP may occur. Thus, it is important to develop algorithms for forced infusion that will ensure a more precise control of the infusion flow. The review describes various forced infusion mechanisms and key approaches to their use, as well as their effectiveness and safety patterns, highlighted in the experimental and clinical studies. </p> <p> <b>Keywords</b>: vitrectomy, intraocular pressure, hydrodynamic balance, forced infusion, microsurgical systems, ultrasonic vitrectomy. </p> <p> <b>For citation:</b> Aznabaev B.M., Mukhamadeev T.R., Dibaev T.I., Ismagilov T.N. The role and mechanisms of intraocular infusion during microinvasive guillotine and ultrasonic vitrectomy. Russian Journal of Clinical Ophthalmology. 2023;23(1):66–70 (in Russ.). DOI: 10.32364/2311-7729-2023-23-1-66-70. </p>
format Article
id doaj-art-ff867ee7490b4c889108e61317f868e6
institution Kabale University
issn 2311-7729
2619-1571
language Russian
publishDate 2023-03-01
publisher Prime-Media
record_format Article
series РМЖ "Клиническая офтальмология"
spelling doaj-art-ff867ee7490b4c889108e61317f868e62025-01-16T09:39:37ZrusPrime-MediaРМЖ "Клиническая офтальмология"2311-77292619-15712023-03-0123131572The role and mechanisms of intraocular infusion during microinvasive guillotine and ultrasonic vitrectomyB.M. Aznabaev0T.R. Mukhamadeev1T.I. Dibaev2T.N. Ismagilov3Russian Journal of Clinical Ophthalmology, Publisher of «Medicina-Inform» Address for correspondence: Russia, 105064, Moscow, P.O. Box 399Russian Journal of Clinical Ophthalmology, Publisher of «Medicina-Inform» Address for correspondence: Russia, 105064, Moscow, P.O. Box 399Russian Journal of Clinical Ophthalmology, Publisher of «Medicina-Inform» Address for correspondence: Russia, 105064, Moscow, P.O. Box 399Russian Journal of Clinical Ophthalmology, Publisher of «Medicina-Inform» Address for correspondence: Russia, 105064, Moscow, P.O. Box 399<p> B.M. Aznabaev<sup>1,2</sup>, T.R. Mukhamadeev<sup>1,2</sup>, T.I. Dibaev<sup>1,2</sup>, T.N. Ismagilov<sup>1,2</sup> </p> <p> <sup>1</sup>Bashkir State Medical University, Ufa, Russian Federation </p> <p> <sup>2</sup>CJSC Optimedservis, Ufa, Russian Federation </p> <p> <br> </p> <p> Maintaining tone of the eyeball and stable intraocular pressure (IOP) during vitrectomy is an important issue associated with the safety of intraocular structures. As the vitreous body is removed, it is gradually replaced with a balanced salt solution, which leads to a decrease in viscosity of the vitreous chamber content and may contribute to changes of the hydrodynamic parameters during surgical procedures. Thus, it is necessary to ensure controlled operation and coordination of the infusion and aspiration modules used in the microsurgical system. Commonly, the imbalance between the aqueous humor inflow and outflow during vitrectomy may cause either a decrease or increase in IOP. The gravity infusion surgical systems cannot compensate for sudden changes in the hydrodynamic parameters during eye surgery, and, as a result, significant fluctuations in IOP may occur. Thus, it is important to develop algorithms for forced infusion that will ensure a more precise control of the infusion flow. The review describes various forced infusion mechanisms and key approaches to their use, as well as their effectiveness and safety patterns, highlighted in the experimental and clinical studies. </p> <p> <b>Keywords</b>: vitrectomy, intraocular pressure, hydrodynamic balance, forced infusion, microsurgical systems, ultrasonic vitrectomy. </p> <p> <b>For citation:</b> Aznabaev B.M., Mukhamadeev T.R., Dibaev T.I., Ismagilov T.N. The role and mechanisms of intraocular infusion during microinvasive guillotine and ultrasonic vitrectomy. Russian Journal of Clinical Ophthalmology. 2023;23(1):66–70 (in Russ.). DOI: 10.32364/2311-7729-2023-23-1-66-70. </p>http://clinopht.com/upload/iblock/56e/dxoy0qg02oia72r62cuoftj07qbxoym6.pdf
spellingShingle B.M. Aznabaev
T.R. Mukhamadeev
T.I. Dibaev
T.N. Ismagilov
The role and mechanisms of intraocular infusion during microinvasive guillotine and ultrasonic vitrectomy
РМЖ "Клиническая офтальмология"
title The role and mechanisms of intraocular infusion during microinvasive guillotine and ultrasonic vitrectomy
title_full The role and mechanisms of intraocular infusion during microinvasive guillotine and ultrasonic vitrectomy
title_fullStr The role and mechanisms of intraocular infusion during microinvasive guillotine and ultrasonic vitrectomy
title_full_unstemmed The role and mechanisms of intraocular infusion during microinvasive guillotine and ultrasonic vitrectomy
title_short The role and mechanisms of intraocular infusion during microinvasive guillotine and ultrasonic vitrectomy
title_sort role and mechanisms of intraocular infusion during microinvasive guillotine and ultrasonic vitrectomy
url http://clinopht.com/upload/iblock/56e/dxoy0qg02oia72r62cuoftj07qbxoym6.pdf
work_keys_str_mv AT bmaznabaev theroleandmechanismsofintraocularinfusionduringmicroinvasiveguillotineandultrasonicvitrectomy
AT trmukhamadeev theroleandmechanismsofintraocularinfusionduringmicroinvasiveguillotineandultrasonicvitrectomy
AT tidibaev theroleandmechanismsofintraocularinfusionduringmicroinvasiveguillotineandultrasonicvitrectomy
AT tnismagilov theroleandmechanismsofintraocularinfusionduringmicroinvasiveguillotineandultrasonicvitrectomy
AT bmaznabaev roleandmechanismsofintraocularinfusionduringmicroinvasiveguillotineandultrasonicvitrectomy
AT trmukhamadeev roleandmechanismsofintraocularinfusionduringmicroinvasiveguillotineandultrasonicvitrectomy
AT tidibaev roleandmechanismsofintraocularinfusionduringmicroinvasiveguillotineandultrasonicvitrectomy
AT tnismagilov roleandmechanismsofintraocularinfusionduringmicroinvasiveguillotineandultrasonicvitrectomy