Modern possibilities of tear film stability restoration

<p> V.V. Brzheskiy, G.G. Кim, V.А. Bobryshev </p> <p> St. Petersburg State Pediatric Medical University, St. Petersburg, Russian Federation </p> <p> The pathogenetic basis of therapy for patients with dry eye syndrome consists of measures aimed at precorneal tear...

Full description

Saved in:
Bibliographic Details
Main Authors: V.V. Brzheskiy, G.G. Кim, V.А. Bobryshev
Format: Article
Language:Russian
Published: Prime-Media 2024-09-01
Series:РМЖ "Клиническая офтальмология"
Online Access:http://clinopht.com/upload/iblock/073/drf0hfc46y2hvinu9pvvosrfgkywq5zs.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841526847124275200
author V.V. Brzheskiy
G.G. Кim
V.А. Bobryshev
author_facet V.V. Brzheskiy
G.G. Кim
V.А. Bobryshev
author_sort V.V. Brzheskiy
collection DOAJ
description <p> V.V. Brzheskiy, G.G. Кim, V.А. Bobryshev </p> <p> St. Petersburg State Pediatric Medical University, St. Petersburg, Russian Federation </p> <p> The pathogenetic basis of therapy for patients with dry eye syndrome consists of measures aimed at precorneal tear film restoration, including deficiency compensation of its lipid layer and aqueous mucin layer (with aqueous and mucin components) respectively. </p> <p> Among the numerous medications, artificial tear substitutes based on the sodium hyaluronate are drawing increasing attention. They differ from other lacrimal substitutes by their high hygroscopicity, thixotropy, mucomimeticity and other metabolic properties (biocompatibility, biodegradability, nonimmunogenicity, anti-inflammatory and regenerative activity, etc.). One of the ways to increase the viscosity, ocular surface stability and humectant duration is the cross-linking of hyaluronic acid using so-called "cross-linking agents" (carbodiimide hydrochloride, urea, divinyl sulfone, thiol-ene reaction, etc.). In vitro and in vivo experiments have proven the possibility of using such modified hyaluronic acid as an artificial tear substitute. </p> <p> The article presents a case study of a patient — a student suffering from computer vision syndrome who unsuccessfully used low viscosity tear substitutes while working at a computer. The use of cross-linked sodium hyaluronate 0.2% (hyaluronic acid sodium salt) in the background mode "by feeling" and at intervals of every 1.5 hours while working at the computer, significantly improved the condition of the patient's ocular surface and increased the duration of his "asymptomatic" time working at the computer. </p> <p> <b>Keywords:</b> dry eye syndrome, cross-linked hyaluronic acid, treatment efficacy. </p> <p> <b>For citation:</b> Brzheskiy V.V., Кim G.G., Bobryshev V.А. Modern possibilities of tear film stability restoration. Russian Journal of Clinical Ophthalmology. 2024;24(3):151–157 (in Russ.). DOI: 10.32364/2311-7729-2024-24-3-7. </p>
format Article
id doaj-art-f5281293281a4ae8adb613ef41e27b28
institution Kabale University
issn 2311-7729
2619-1571
language Russian
publishDate 2024-09-01
publisher Prime-Media
record_format Article
series РМЖ "Клиническая офтальмология"
spelling doaj-art-f5281293281a4ae8adb613ef41e27b282025-01-16T09:39:38ZrusPrime-MediaРМЖ "Клиническая офтальмология"2311-77292619-15712024-09-0124331777Modern possibilities of tear film stability restorationV.V. Brzheskiy0G.G. Кim1V.А. Bobryshev2Russian Journal of Clinical Ophthalmology, Publisher of «Medicina-Inform» Address for correspondence: Russia, 105064, Moscow, P.O. Box 399Russian Journal of Clinical Ophthalmology, Publisher of «Medicina-Inform» Address for correspondence: Russia, 105064, Moscow, P.O. Box 399Russian Journal of Clinical Ophthalmology, Publisher of «Medicina-Inform» Address for correspondence: Russia, 105064, Moscow, P.O. Box 399<p> V.V. Brzheskiy, G.G. Кim, V.А. Bobryshev </p> <p> St. Petersburg State Pediatric Medical University, St. Petersburg, Russian Federation </p> <p> The pathogenetic basis of therapy for patients with dry eye syndrome consists of measures aimed at precorneal tear film restoration, including deficiency compensation of its lipid layer and aqueous mucin layer (with aqueous and mucin components) respectively. </p> <p> Among the numerous medications, artificial tear substitutes based on the sodium hyaluronate are drawing increasing attention. They differ from other lacrimal substitutes by their high hygroscopicity, thixotropy, mucomimeticity and other metabolic properties (biocompatibility, biodegradability, nonimmunogenicity, anti-inflammatory and regenerative activity, etc.). One of the ways to increase the viscosity, ocular surface stability and humectant duration is the cross-linking of hyaluronic acid using so-called "cross-linking agents" (carbodiimide hydrochloride, urea, divinyl sulfone, thiol-ene reaction, etc.). In vitro and in vivo experiments have proven the possibility of using such modified hyaluronic acid as an artificial tear substitute. </p> <p> The article presents a case study of a patient — a student suffering from computer vision syndrome who unsuccessfully used low viscosity tear substitutes while working at a computer. The use of cross-linked sodium hyaluronate 0.2% (hyaluronic acid sodium salt) in the background mode "by feeling" and at intervals of every 1.5 hours while working at the computer, significantly improved the condition of the patient's ocular surface and increased the duration of his "asymptomatic" time working at the computer. </p> <p> <b>Keywords:</b> dry eye syndrome, cross-linked hyaluronic acid, treatment efficacy. </p> <p> <b>For citation:</b> Brzheskiy V.V., Кim G.G., Bobryshev V.А. Modern possibilities of tear film stability restoration. Russian Journal of Clinical Ophthalmology. 2024;24(3):151–157 (in Russ.). DOI: 10.32364/2311-7729-2024-24-3-7. </p>http://clinopht.com/upload/iblock/073/drf0hfc46y2hvinu9pvvosrfgkywq5zs.pdf
spellingShingle V.V. Brzheskiy
G.G. Кim
V.А. Bobryshev
Modern possibilities of tear film stability restoration
РМЖ "Клиническая офтальмология"
title Modern possibilities of tear film stability restoration
title_full Modern possibilities of tear film stability restoration
title_fullStr Modern possibilities of tear film stability restoration
title_full_unstemmed Modern possibilities of tear film stability restoration
title_short Modern possibilities of tear film stability restoration
title_sort modern possibilities of tear film stability restoration
url http://clinopht.com/upload/iblock/073/drf0hfc46y2hvinu9pvvosrfgkywq5zs.pdf
work_keys_str_mv AT vvbrzheskiy modernpossibilitiesoftearfilmstabilityrestoration
AT ggkim modernpossibilitiesoftearfilmstabilityrestoration
AT vabobryshev modernpossibilitiesoftearfilmstabilityrestoration