Quantification of Replacement Fibrosis in Aortic Stenosis: A Narrative Review on the Utility of Cardiovascular Magnetic Resonance Imaging

Aortic stenosis (AS) is associated with the development of replacement myocardial fibrosis/scar. Given the dose-dependent relationship between scar and clinical outcomes after aortic valve replacement (AVR) surgery, scar quantity may serve as an important risk-stratification tool to aid decision-mak...

Full description

Saved in:
Bibliographic Details
Main Authors: Megan R. Rajah, Anton F. Doubell, Philip G. Herbst
Format: Article
Language:English
Published: MDPI AG 2024-10-01
Series:Diagnostics
Subjects:
Online Access:https://www.mdpi.com/2075-4418/14/21/2435
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1846173494159605760
author Megan R. Rajah
Anton F. Doubell
Philip G. Herbst
author_facet Megan R. Rajah
Anton F. Doubell
Philip G. Herbst
author_sort Megan R. Rajah
collection DOAJ
description Aortic stenosis (AS) is associated with the development of replacement myocardial fibrosis/scar. Given the dose-dependent relationship between scar and clinical outcomes after aortic valve replacement (AVR) surgery, scar quantity may serve as an important risk-stratification tool to aid decision-making on the optimal timing of AVR. Scar is non-invasively assessed and quantified by cardiovascular magnetic resonance (CMR) imaging. Several quantification techniques exist, and consensus on the optimal technique is lacking. These techniques range from a visual manual method to fully automated ones. This review describes the different scar quantification techniques used and highlights their strengths and shortfalls within the context of AS. The two most commonly used techniques in AS include the semi-automated signal threshold versus reference mean (STRM) and full-width half-maximum (FWHM) techniques. The accuracy and reproducibility of these techniques may be hindered in AS by the coexistence of diffuse interstitial fibrosis and the presence of relatively small, non-bright scars. The validation of these techniques against histology, which is the current gold standard for scar quantification in AS, is limited. Based on the best current evidence, the STRM method using a threshold of three standard deviations above the mean signal intensity of remote myocardium is recommended. The high reproducibility of the FWHM technique in non-AS cohorts has been shown and merits further evaluation within the context of AS. Future directions include the use of quantitative T1 mapping for the detection and quantification of scar, as well as the development of serum biomarkers that reflect the fibrotic status of the myocardium in AS.
format Article
id doaj-art-f052f7ae3bb049a48dac1195bd02ef5c
institution Kabale University
issn 2075-4418
language English
publishDate 2024-10-01
publisher MDPI AG
record_format Article
series Diagnostics
spelling doaj-art-f052f7ae3bb049a48dac1195bd02ef5c2024-11-08T14:34:56ZengMDPI AGDiagnostics2075-44182024-10-011421243510.3390/diagnostics14212435Quantification of Replacement Fibrosis in Aortic Stenosis: A Narrative Review on the Utility of Cardiovascular Magnetic Resonance ImagingMegan R. Rajah0Anton F. Doubell1Philip G. Herbst2Division of Cardiology, Department of Medicine, Faculty of Medicine and Health Sciences, Stellenbosch University and Tygerberg Hospital, Cape Town 7505, South AfricaDivision of Cardiology, Department of Medicine, Faculty of Medicine and Health Sciences, Stellenbosch University and Tygerberg Hospital, Cape Town 7505, South AfricaDivision of Cardiology, Department of Medicine, Faculty of Medicine and Health Sciences, Stellenbosch University and Tygerberg Hospital, Cape Town 7505, South AfricaAortic stenosis (AS) is associated with the development of replacement myocardial fibrosis/scar. Given the dose-dependent relationship between scar and clinical outcomes after aortic valve replacement (AVR) surgery, scar quantity may serve as an important risk-stratification tool to aid decision-making on the optimal timing of AVR. Scar is non-invasively assessed and quantified by cardiovascular magnetic resonance (CMR) imaging. Several quantification techniques exist, and consensus on the optimal technique is lacking. These techniques range from a visual manual method to fully automated ones. This review describes the different scar quantification techniques used and highlights their strengths and shortfalls within the context of AS. The two most commonly used techniques in AS include the semi-automated signal threshold versus reference mean (STRM) and full-width half-maximum (FWHM) techniques. The accuracy and reproducibility of these techniques may be hindered in AS by the coexistence of diffuse interstitial fibrosis and the presence of relatively small, non-bright scars. The validation of these techniques against histology, which is the current gold standard for scar quantification in AS, is limited. Based on the best current evidence, the STRM method using a threshold of three standard deviations above the mean signal intensity of remote myocardium is recommended. The high reproducibility of the FWHM technique in non-AS cohorts has been shown and merits further evaluation within the context of AS. Future directions include the use of quantitative T1 mapping for the detection and quantification of scar, as well as the development of serum biomarkers that reflect the fibrotic status of the myocardium in AS.https://www.mdpi.com/2075-4418/14/21/2435late gadolinium enhancementmyocardial fibrosisreplacement fibrosisscar quantificationLGE quantificationaortic stenosis
spellingShingle Megan R. Rajah
Anton F. Doubell
Philip G. Herbst
Quantification of Replacement Fibrosis in Aortic Stenosis: A Narrative Review on the Utility of Cardiovascular Magnetic Resonance Imaging
Diagnostics
late gadolinium enhancement
myocardial fibrosis
replacement fibrosis
scar quantification
LGE quantification
aortic stenosis
title Quantification of Replacement Fibrosis in Aortic Stenosis: A Narrative Review on the Utility of Cardiovascular Magnetic Resonance Imaging
title_full Quantification of Replacement Fibrosis in Aortic Stenosis: A Narrative Review on the Utility of Cardiovascular Magnetic Resonance Imaging
title_fullStr Quantification of Replacement Fibrosis in Aortic Stenosis: A Narrative Review on the Utility of Cardiovascular Magnetic Resonance Imaging
title_full_unstemmed Quantification of Replacement Fibrosis in Aortic Stenosis: A Narrative Review on the Utility of Cardiovascular Magnetic Resonance Imaging
title_short Quantification of Replacement Fibrosis in Aortic Stenosis: A Narrative Review on the Utility of Cardiovascular Magnetic Resonance Imaging
title_sort quantification of replacement fibrosis in aortic stenosis a narrative review on the utility of cardiovascular magnetic resonance imaging
topic late gadolinium enhancement
myocardial fibrosis
replacement fibrosis
scar quantification
LGE quantification
aortic stenosis
url https://www.mdpi.com/2075-4418/14/21/2435
work_keys_str_mv AT meganrrajah quantificationofreplacementfibrosisinaorticstenosisanarrativereviewontheutilityofcardiovascularmagneticresonanceimaging
AT antonfdoubell quantificationofreplacementfibrosisinaorticstenosisanarrativereviewontheutilityofcardiovascularmagneticresonanceimaging
AT philipgherbst quantificationofreplacementfibrosisinaorticstenosisanarrativereviewontheutilityofcardiovascularmagneticresonanceimaging