Small-Animal X-ray Dose from Micro-CT

The use of micro-CT in small animals has increased in recent years. Although the radiation levels used for micro-CT are generally not lethal to the animal, they are high enough where changes in the immune response and other biological pathways may alter the experimental outcomes. Therefore, it is im...

Full description

Saved in:
Bibliographic Details
Main Authors: John M. Boone, Orlando Velazquez, Simon R. Cherry
Format: Article
Language:English
Published: SAGE Publishing 2004-07-01
Series:Molecular Imaging
Online Access:https://doi.org/10.1162/15353500200404118
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841563256098914304
author John M. Boone
Orlando Velazquez
Simon R. Cherry
author_facet John M. Boone
Orlando Velazquez
Simon R. Cherry
author_sort John M. Boone
collection DOAJ
description The use of micro-CT in small animals has increased in recent years. Although the radiation levels used for micro-CT are generally not lethal to the animal, they are high enough where changes in the immune response and other biological pathways may alter the experimental outcomes. Therefore, it is important to understand what the doses are for a specific imaging procedure. Monte Carlo simulation was used to evaluate the radiation dose to small animals (5–40 mm in diameter) as a result of X-ray exposure. Both monoenergetic (6–100 keV) and polyenergetic (15–100 kVp) X-ray sources were simulated under typical mouse imaging geometries. X-ray spectral measurements were performed on a mouse imaging X-ray system using a commercially available X-ray spectrometer, and spectra from high-energy systems were used as well. For a typical X-ray system with 1.0 mm of added Al at 40 kVp, the dose coefficients (dose to mouse per air kerma at isocenter) were 0.80, 0.63, 0.52, and 0.44 mGy/mGy for mouse diameters of 10, 20, 30, and 40 mm, respectively. A number of tables and figures are provided for dose estimation over a range of mouse imaging geometries.
format Article
id doaj-art-edfa49b1cbfa43c385b3465a1393caa6
institution Kabale University
issn 1536-0121
language English
publishDate 2004-07-01
publisher SAGE Publishing
record_format Article
series Molecular Imaging
spelling doaj-art-edfa49b1cbfa43c385b3465a1393caa62025-01-03T00:10:26ZengSAGE PublishingMolecular Imaging1536-01212004-07-01310.1162/1535350020040411810.1162_15353500200404118Small-Animal X-ray Dose from Micro-CTJohn M. BooneOrlando VelazquezSimon R. CherryThe use of micro-CT in small animals has increased in recent years. Although the radiation levels used for micro-CT are generally not lethal to the animal, they are high enough where changes in the immune response and other biological pathways may alter the experimental outcomes. Therefore, it is important to understand what the doses are for a specific imaging procedure. Monte Carlo simulation was used to evaluate the radiation dose to small animals (5–40 mm in diameter) as a result of X-ray exposure. Both monoenergetic (6–100 keV) and polyenergetic (15–100 kVp) X-ray sources were simulated under typical mouse imaging geometries. X-ray spectral measurements were performed on a mouse imaging X-ray system using a commercially available X-ray spectrometer, and spectra from high-energy systems were used as well. For a typical X-ray system with 1.0 mm of added Al at 40 kVp, the dose coefficients (dose to mouse per air kerma at isocenter) were 0.80, 0.63, 0.52, and 0.44 mGy/mGy for mouse diameters of 10, 20, 30, and 40 mm, respectively. A number of tables and figures are provided for dose estimation over a range of mouse imaging geometries.https://doi.org/10.1162/15353500200404118
spellingShingle John M. Boone
Orlando Velazquez
Simon R. Cherry
Small-Animal X-ray Dose from Micro-CT
Molecular Imaging
title Small-Animal X-ray Dose from Micro-CT
title_full Small-Animal X-ray Dose from Micro-CT
title_fullStr Small-Animal X-ray Dose from Micro-CT
title_full_unstemmed Small-Animal X-ray Dose from Micro-CT
title_short Small-Animal X-ray Dose from Micro-CT
title_sort small animal x ray dose from micro ct
url https://doi.org/10.1162/15353500200404118
work_keys_str_mv AT johnmboone smallanimalxraydosefrommicroct
AT orlandovelazquez smallanimalxraydosefrommicroct
AT simonrcherry smallanimalxraydosefrommicroct