Active Control and Energy Cost Assessment of a Rotating Machine
The performances for controlling a rotating machine by using either an Electromagnetic Actuator or a Piezoelectric Actuator are compared in this work. The aim is to establish selection criteria based on environmental impact. Life Cycle Analysis shows that the operating stage has a considerable impac...
Saved in:
| Main Authors: | , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Wiley
2011-01-01
|
| Series: | Shock and Vibration |
| Online Access: | http://dx.doi.org/10.3233/SAV-2010-0576 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1849690214107185152 |
|---|---|
| author | Jarir Mahfoud Yan Skladanek Johan Der Hagopian |
| author_facet | Jarir Mahfoud Yan Skladanek Johan Der Hagopian |
| author_sort | Jarir Mahfoud |
| collection | DOAJ |
| description | The performances for controlling a rotating machine by using either an Electromagnetic Actuator or a Piezoelectric Actuator are compared in this work. The aim is to establish selection criteria based on environmental impact. Life Cycle Analysis shows that the operating stage has a considerable impact. In this study, only the operating stage is considered. The energy consumed by the actuators seems to be the appropriate indicator for the same "mechanical" performances. Numerical studies are carried out in order to quantify the energy consumed in each case. Modal control strategy with a fuzzy controller is used. The controller inputs are displacements and velocities. The system studied is modeled by using finite element method and the electrical circuit of each actuator is modeled by using basic electricity and electromagnetism theories. Several configurations are assessed and defined by using the chosen Functional Unit. |
| format | Article |
| id | doaj-art-ecdde1e41d7e4662a96af6af7d543f4f |
| institution | DOAJ |
| issn | 1070-9622 1875-9203 |
| language | English |
| publishDate | 2011-01-01 |
| publisher | Wiley |
| record_format | Article |
| series | Shock and Vibration |
| spelling | doaj-art-ecdde1e41d7e4662a96af6af7d543f4f2025-08-20T03:21:23ZengWileyShock and Vibration1070-96221875-92032011-01-0118461362510.3233/SAV-2010-0576Active Control and Energy Cost Assessment of a Rotating MachineJarir Mahfoud0Yan Skladanek1Johan Der Hagopian2Université de Lyon, CNRS, INSA-Lyon, LaMCoS UMR5259, Villeurbanne Cedex, FranceUniversité de Lyon, CNRS, INSA-Lyon, LaMCoS UMR5259, Villeurbanne Cedex, FranceUniversité de Lyon, CNRS, INSA-Lyon, LaMCoS UMR5259, Villeurbanne Cedex, FranceThe performances for controlling a rotating machine by using either an Electromagnetic Actuator or a Piezoelectric Actuator are compared in this work. The aim is to establish selection criteria based on environmental impact. Life Cycle Analysis shows that the operating stage has a considerable impact. In this study, only the operating stage is considered. The energy consumed by the actuators seems to be the appropriate indicator for the same "mechanical" performances. Numerical studies are carried out in order to quantify the energy consumed in each case. Modal control strategy with a fuzzy controller is used. The controller inputs are displacements and velocities. The system studied is modeled by using finite element method and the electrical circuit of each actuator is modeled by using basic electricity and electromagnetism theories. Several configurations are assessed and defined by using the chosen Functional Unit.http://dx.doi.org/10.3233/SAV-2010-0576 |
| spellingShingle | Jarir Mahfoud Yan Skladanek Johan Der Hagopian Active Control and Energy Cost Assessment of a Rotating Machine Shock and Vibration |
| title | Active Control and Energy Cost Assessment of a Rotating Machine |
| title_full | Active Control and Energy Cost Assessment of a Rotating Machine |
| title_fullStr | Active Control and Energy Cost Assessment of a Rotating Machine |
| title_full_unstemmed | Active Control and Energy Cost Assessment of a Rotating Machine |
| title_short | Active Control and Energy Cost Assessment of a Rotating Machine |
| title_sort | active control and energy cost assessment of a rotating machine |
| url | http://dx.doi.org/10.3233/SAV-2010-0576 |
| work_keys_str_mv | AT jarirmahfoud activecontrolandenergycostassessmentofarotatingmachine AT yanskladanek activecontrolandenergycostassessmentofarotatingmachine AT johanderhagopian activecontrolandenergycostassessmentofarotatingmachine |