Enhancing the efficiency of a wavelength-dispersive spectrometer based on a slitless design using a single-bounce monocapillary

This paper introduces a novel slit-less wavelength-dispersive spectrometer design that incorporates a single-bounce monocapillary with the goal of positioning the sample directly on the Rowland circle, thereby eliminating the need for a traditional entrance slit. This configuration enhances photon t...

Full description

Saved in:
Bibliographic Details
Main Authors: Karina Bzheumikhova, Y. Kayser, R. Unterumsberger, J. Weser, C. Stadelhoff, B. Beckhoff
Format: Article
Language:English
Published: International Union of Crystallography 2025-01-01
Series:Journal of Synchrotron Radiation
Subjects:
Online Access:https://journals.iucr.org/paper?S1600577524010683
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841556128016629760
author Karina Bzheumikhova
Y. Kayser
R. Unterumsberger
J. Weser
C. Stadelhoff
B. Beckhoff
author_facet Karina Bzheumikhova
Y. Kayser
R. Unterumsberger
J. Weser
C. Stadelhoff
B. Beckhoff
author_sort Karina Bzheumikhova
collection DOAJ
description This paper introduces a novel slit-less wavelength-dispersive spectrometer design that incorporates a single-bounce monocapillary with the goal of positioning the sample directly on the Rowland circle, thereby eliminating the need for a traditional entrance slit. This configuration enhances photon throughput while preserving energy resolution, demonstrated in comparative measurements on boron nitride and different lithium nickel manganese cobalt oxide cathodes. A common alternative to an entrance slit for limiting the source size on the Rowland circle is a customized design of the beamline involving a focusing optics unit consisting of two Kirkpatrick–Baez mirrors close to the end station. The new slit-less design does not rely on specialized beamlines and can be considered, thanks to the increased efficiency, for spectrometers using laboratory based sources equipped with equivalent optics. The comparative measurements found that the resolving power achieved was E/ΔE = 1085 at 401.5 eV incident energy, and the enhancement in detection efficiency was a factor of 3.7 due to more effective utilization of the X-ray beam.
format Article
id doaj-art-e85ef2c4aa0f43c69e1caab109ec07e4
institution Kabale University
issn 1600-5775
language English
publishDate 2025-01-01
publisher International Union of Crystallography
record_format Article
series Journal of Synchrotron Radiation
spelling doaj-art-e85ef2c4aa0f43c69e1caab109ec07e42025-01-07T14:26:38ZengInternational Union of CrystallographyJournal of Synchrotron Radiation1600-57752025-01-0132117117910.1107/S1600577524010683ing5003Enhancing the efficiency of a wavelength-dispersive spectrometer based on a slitless design using a single-bounce monocapillaryKarina Bzheumikhova0Y. Kayser1R. Unterumsberger2J. Weser3C. Stadelhoff4B. Beckhoff5Physikalisch-Technische Bundesanstalt, Abbestraße 2-12, Berlin, GermanyPhysikalisch-Technische Bundesanstalt, Abbestraße 2-12, Berlin, GermanyHelmut Fischer GmbH Institut für Elektronik und Messtechnik, Industriestrasse 21, 71069 Sindelfingen, GermanyPhysikalisch-Technische Bundesanstalt, Abbestraße 2-12, Berlin, GermanyPhysikalisch-Technische Bundesanstalt, Abbestraße 2-12, Berlin, GermanyPhysikalisch-Technische Bundesanstalt, Abbestraße 2-12, Berlin, GermanyThis paper introduces a novel slit-less wavelength-dispersive spectrometer design that incorporates a single-bounce monocapillary with the goal of positioning the sample directly on the Rowland circle, thereby eliminating the need for a traditional entrance slit. This configuration enhances photon throughput while preserving energy resolution, demonstrated in comparative measurements on boron nitride and different lithium nickel manganese cobalt oxide cathodes. A common alternative to an entrance slit for limiting the source size on the Rowland circle is a customized design of the beamline involving a focusing optics unit consisting of two Kirkpatrick–Baez mirrors close to the end station. The new slit-less design does not rely on specialized beamlines and can be considered, thanks to the increased efficiency, for spectrometers using laboratory based sources equipped with equivalent optics. The comparative measurements found that the resolving power achieved was E/ΔE = 1085 at 401.5 eV incident energy, and the enhancement in detection efficiency was a factor of 3.7 due to more effective utilization of the X-ray beam.https://journals.iucr.org/paper?S1600577524010683single-bounce monocapillariesx-ray emission spectroscopyspectrometerssynchrotron radiationinstrumental energy resolutiondetection efficiency
spellingShingle Karina Bzheumikhova
Y. Kayser
R. Unterumsberger
J. Weser
C. Stadelhoff
B. Beckhoff
Enhancing the efficiency of a wavelength-dispersive spectrometer based on a slitless design using a single-bounce monocapillary
Journal of Synchrotron Radiation
single-bounce monocapillaries
x-ray emission spectroscopy
spectrometers
synchrotron radiation
instrumental energy resolution
detection efficiency
title Enhancing the efficiency of a wavelength-dispersive spectrometer based on a slitless design using a single-bounce monocapillary
title_full Enhancing the efficiency of a wavelength-dispersive spectrometer based on a slitless design using a single-bounce monocapillary
title_fullStr Enhancing the efficiency of a wavelength-dispersive spectrometer based on a slitless design using a single-bounce monocapillary
title_full_unstemmed Enhancing the efficiency of a wavelength-dispersive spectrometer based on a slitless design using a single-bounce monocapillary
title_short Enhancing the efficiency of a wavelength-dispersive spectrometer based on a slitless design using a single-bounce monocapillary
title_sort enhancing the efficiency of a wavelength dispersive spectrometer based on a slitless design using a single bounce monocapillary
topic single-bounce monocapillaries
x-ray emission spectroscopy
spectrometers
synchrotron radiation
instrumental energy resolution
detection efficiency
url https://journals.iucr.org/paper?S1600577524010683
work_keys_str_mv AT karinabzheumikhova enhancingtheefficiencyofawavelengthdispersivespectrometerbasedonaslitlessdesignusingasinglebouncemonocapillary
AT ykayser enhancingtheefficiencyofawavelengthdispersivespectrometerbasedonaslitlessdesignusingasinglebouncemonocapillary
AT runterumsberger enhancingtheefficiencyofawavelengthdispersivespectrometerbasedonaslitlessdesignusingasinglebouncemonocapillary
AT jweser enhancingtheefficiencyofawavelengthdispersivespectrometerbasedonaslitlessdesignusingasinglebouncemonocapillary
AT cstadelhoff enhancingtheefficiencyofawavelengthdispersivespectrometerbasedonaslitlessdesignusingasinglebouncemonocapillary
AT bbeckhoff enhancingtheefficiencyofawavelengthdispersivespectrometerbasedonaslitlessdesignusingasinglebouncemonocapillary