In Vivo Resolution of Multiexponential Decays of Multiple Near-Infrared Molecular Probes by Fluorescence Lifetime-Gated Whole-Body Time-Resolved Diffuse Optical Imaging

The biodistribution of two near-infrared fluorescent agents was assessed in vivo by time-resolved diffuse optical imaging. Bacteriochlorophyll a (BC) and cypate-glysine-arginine-aspartic acid-serine-proline-lysine-OH (Cyp-GRD) were administered separately or combined to mice with subcutaneous xenogr...

Full description

Saved in:
Bibliographic Details
Main Authors: Walter Akers, Frederic Lesage, Dewey Holten, Samuel Achilefu
Format: Article
Language:English
Published: SAGE Publishing 2007-07-01
Series:Molecular Imaging
Online Access:https://doi.org/10.2310/7290.2007.00020
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841563113930883072
author Walter Akers
Frederic Lesage
Dewey Holten
Samuel Achilefu
author_facet Walter Akers
Frederic Lesage
Dewey Holten
Samuel Achilefu
author_sort Walter Akers
collection DOAJ
description The biodistribution of two near-infrared fluorescent agents was assessed in vivo by time-resolved diffuse optical imaging. Bacteriochlorophyll a (BC) and cypate-glysine-arginine-aspartic acid-serine-proline-lysine-OH (Cyp-GRD) were administered separately or combined to mice with subcutaneous xenografts of human breast adenocarcinoma and slow-release estradiol pellets for improved tumor growth. The same excitation (780 nm) and emission (830 nm) wavelengths were used to image the distinct fluorescence lifetime distribution of the fluorescent molecular probes in the mouse cancer model. Fluorescence intensity and lifetime maps were reconstructed after raster-scanning whole-body regions of interest by time-correlated single-photon counting. Each captured temporal point-spread function (TPSF) was deconvolved using both a single and a multiexponental decay model to best determine the measured fluorescence lifetimes. The relative signal from each fluorophore was estimated for any region of interest included in the scanned area. Deconvolution of the individual TPSFs from whole-body fluorescence intensity scans provided corresponding lifetime images for comparing individual component biodistribution. In vivo fluorescence lifetimes were determined to be 0.8 ns (Cyp-GRD) and 2 ns (BC). This study demonstrates that the relative biodistribution of individual fluorophores with similar spectral characteristics can be compartmentalized by using the time-domain fluorescence lifetime gating method.
format Article
id doaj-art-e7b4b6589bf34d04b6abf54eb5fcf06a
institution Kabale University
issn 1536-0121
language English
publishDate 2007-07-01
publisher SAGE Publishing
record_format Article
series Molecular Imaging
spelling doaj-art-e7b4b6589bf34d04b6abf54eb5fcf06a2025-01-03T00:12:14ZengSAGE PublishingMolecular Imaging1536-01212007-07-01610.2310/7290.2007.0002010.2310_7290.2007.00020In Vivo Resolution of Multiexponential Decays of Multiple Near-Infrared Molecular Probes by Fluorescence Lifetime-Gated Whole-Body Time-Resolved Diffuse Optical ImagingWalter AkersFrederic LesageDewey HoltenSamuel AchilefuThe biodistribution of two near-infrared fluorescent agents was assessed in vivo by time-resolved diffuse optical imaging. Bacteriochlorophyll a (BC) and cypate-glysine-arginine-aspartic acid-serine-proline-lysine-OH (Cyp-GRD) were administered separately or combined to mice with subcutaneous xenografts of human breast adenocarcinoma and slow-release estradiol pellets for improved tumor growth. The same excitation (780 nm) and emission (830 nm) wavelengths were used to image the distinct fluorescence lifetime distribution of the fluorescent molecular probes in the mouse cancer model. Fluorescence intensity and lifetime maps were reconstructed after raster-scanning whole-body regions of interest by time-correlated single-photon counting. Each captured temporal point-spread function (TPSF) was deconvolved using both a single and a multiexponental decay model to best determine the measured fluorescence lifetimes. The relative signal from each fluorophore was estimated for any region of interest included in the scanned area. Deconvolution of the individual TPSFs from whole-body fluorescence intensity scans provided corresponding lifetime images for comparing individual component biodistribution. In vivo fluorescence lifetimes were determined to be 0.8 ns (Cyp-GRD) and 2 ns (BC). This study demonstrates that the relative biodistribution of individual fluorophores with similar spectral characteristics can be compartmentalized by using the time-domain fluorescence lifetime gating method.https://doi.org/10.2310/7290.2007.00020
spellingShingle Walter Akers
Frederic Lesage
Dewey Holten
Samuel Achilefu
In Vivo Resolution of Multiexponential Decays of Multiple Near-Infrared Molecular Probes by Fluorescence Lifetime-Gated Whole-Body Time-Resolved Diffuse Optical Imaging
Molecular Imaging
title In Vivo Resolution of Multiexponential Decays of Multiple Near-Infrared Molecular Probes by Fluorescence Lifetime-Gated Whole-Body Time-Resolved Diffuse Optical Imaging
title_full In Vivo Resolution of Multiexponential Decays of Multiple Near-Infrared Molecular Probes by Fluorescence Lifetime-Gated Whole-Body Time-Resolved Diffuse Optical Imaging
title_fullStr In Vivo Resolution of Multiexponential Decays of Multiple Near-Infrared Molecular Probes by Fluorescence Lifetime-Gated Whole-Body Time-Resolved Diffuse Optical Imaging
title_full_unstemmed In Vivo Resolution of Multiexponential Decays of Multiple Near-Infrared Molecular Probes by Fluorescence Lifetime-Gated Whole-Body Time-Resolved Diffuse Optical Imaging
title_short In Vivo Resolution of Multiexponential Decays of Multiple Near-Infrared Molecular Probes by Fluorescence Lifetime-Gated Whole-Body Time-Resolved Diffuse Optical Imaging
title_sort in vivo resolution of multiexponential decays of multiple near infrared molecular probes by fluorescence lifetime gated whole body time resolved diffuse optical imaging
url https://doi.org/10.2310/7290.2007.00020
work_keys_str_mv AT walterakers invivoresolutionofmultiexponentialdecaysofmultiplenearinfraredmolecularprobesbyfluorescencelifetimegatedwholebodytimeresolveddiffuseopticalimaging
AT fredericlesage invivoresolutionofmultiexponentialdecaysofmultiplenearinfraredmolecularprobesbyfluorescencelifetimegatedwholebodytimeresolveddiffuseopticalimaging
AT deweyholten invivoresolutionofmultiexponentialdecaysofmultiplenearinfraredmolecularprobesbyfluorescencelifetimegatedwholebodytimeresolveddiffuseopticalimaging
AT samuelachilefu invivoresolutionofmultiexponentialdecaysofmultiplenearinfraredmolecularprobesbyfluorescencelifetimegatedwholebodytimeresolveddiffuseopticalimaging