Harmonic analysis of multiplex rectifier circuits based on diode rectifiers for offshore wind farms
As the rectification-side devices of the offshore wind power transmission systems, the diode uncontrolled rectification units are a technological hotspot in the offshore wind power sector. Multiplex rectifier circuits are usually employed for diode uncontrolled rectification, with a 12-pulse rectifi...
Saved in:
| Main Authors: | , , , , , , |
|---|---|
| Format: | Article |
| Language: | zho |
| Published: |
zhejiang electric power
2024-11-01
|
| Series: | Zhejiang dianli |
| Subjects: | |
| Online Access: | https://zjdl.cbpt.cnki.net/WKE3/WebPublication/paperDigest.aspx?paperID=a2720db3-f587-4da7-be4e-84ce6539638d |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1846157702836781056 |
|---|---|
| author | XU Feng CAO Wenbin QIAN Zhengxu HUANG Xiaoming LIANG Peng ZHANG Zheren XU Zheng |
| author_facet | XU Feng CAO Wenbin QIAN Zhengxu HUANG Xiaoming LIANG Peng ZHANG Zheren XU Zheng |
| author_sort | XU Feng |
| collection | DOAJ |
| description | As the rectification-side devices of the offshore wind power transmission systems, the diode uncontrolled rectification units are a technological hotspot in the offshore wind power sector. Multiplex rectifier circuits are usually employed for diode uncontrolled rectification, with a 12-pulse rectifier circuits being the most common. Theoretical analyses of serial and parallel multiplex wiring in the 12-pulse and the 24-pulse rectifier circuits within the multiplex rectifier circuits have been conducted. This entails studying the harmonic characteristics of the alternating current on the AC side and the voltage on the DC side, deriving the calculation methods for the harmonic numbers and the harmonic amplitudes, and determining the total current harmonic distortion rate and the voltage ripple factor. Comparative analyses are made on the characteristics of 12-pulse and 24-pulse rectifier circuits, investigating the feasibility of applying the 24-pulse rectifier circuits in the diode uncontrolled rectification units. Simulations are carried out on the PSCAD/EMTDC platform. |
| format | Article |
| id | doaj-art-e77a7e7e581143f18222c0f5677afc19 |
| institution | Kabale University |
| issn | 1007-1881 |
| language | zho |
| publishDate | 2024-11-01 |
| publisher | zhejiang electric power |
| record_format | Article |
| series | Zhejiang dianli |
| spelling | doaj-art-e77a7e7e581143f18222c0f5677afc192024-11-25T06:18:02Zzhozhejiang electric powerZhejiang dianli1007-18812024-11-014311152510.19585/j.zjdl.2024110031007-1881(2024)11-0015-11Harmonic analysis of multiplex rectifier circuits based on diode rectifiers for offshore wind farmsXU Feng0CAO Wenbin1QIAN Zhengxu2HUANG Xiaoming3LIANG Peng4ZHANG Zheren5XU Zheng6State Grid Zhejiang Electric Power Co., Ltd. Research Institute, Hangzhou 310014, ChinaState Grid Zhejiang Electric Power Co., Ltd. Research Institute, Hangzhou 310014, ChinaState Grid Zhejiang Electric Power Co., Ltd. Research Institute, Hangzhou 310014, ChinaState Grid Zhejiang Electric Power Co., Ltd. Research Institute, Hangzhou 310014, ChinaCollege of Electrical Engineering, Zhejiang University, Hangzhou 310027, ChinaCollege of Electrical Engineering, Zhejiang University, Hangzhou 310027, ChinaCollege of Electrical Engineering, Zhejiang University, Hangzhou 310027, ChinaAs the rectification-side devices of the offshore wind power transmission systems, the diode uncontrolled rectification units are a technological hotspot in the offshore wind power sector. Multiplex rectifier circuits are usually employed for diode uncontrolled rectification, with a 12-pulse rectifier circuits being the most common. Theoretical analyses of serial and parallel multiplex wiring in the 12-pulse and the 24-pulse rectifier circuits within the multiplex rectifier circuits have been conducted. This entails studying the harmonic characteristics of the alternating current on the AC side and the voltage on the DC side, deriving the calculation methods for the harmonic numbers and the harmonic amplitudes, and determining the total current harmonic distortion rate and the voltage ripple factor. Comparative analyses are made on the characteristics of 12-pulse and 24-pulse rectifier circuits, investigating the feasibility of applying the 24-pulse rectifier circuits in the diode uncontrolled rectification units. Simulations are carried out on the PSCAD/EMTDC platform.https://zjdl.cbpt.cnki.net/WKE3/WebPublication/paperDigest.aspx?paperID=a2720db3-f587-4da7-be4e-84ce6539638dmultiplex rectifier circuits12-pulse rectifier circuit24-pulse rectifier circuitharmonic analysispscad/emtdc simulation |
| spellingShingle | XU Feng CAO Wenbin QIAN Zhengxu HUANG Xiaoming LIANG Peng ZHANG Zheren XU Zheng Harmonic analysis of multiplex rectifier circuits based on diode rectifiers for offshore wind farms Zhejiang dianli multiplex rectifier circuits 12-pulse rectifier circuit 24-pulse rectifier circuit harmonic analysis pscad/emtdc simulation |
| title | Harmonic analysis of multiplex rectifier circuits based on diode rectifiers for offshore wind farms |
| title_full | Harmonic analysis of multiplex rectifier circuits based on diode rectifiers for offshore wind farms |
| title_fullStr | Harmonic analysis of multiplex rectifier circuits based on diode rectifiers for offshore wind farms |
| title_full_unstemmed | Harmonic analysis of multiplex rectifier circuits based on diode rectifiers for offshore wind farms |
| title_short | Harmonic analysis of multiplex rectifier circuits based on diode rectifiers for offshore wind farms |
| title_sort | harmonic analysis of multiplex rectifier circuits based on diode rectifiers for offshore wind farms |
| topic | multiplex rectifier circuits 12-pulse rectifier circuit 24-pulse rectifier circuit harmonic analysis pscad/emtdc simulation |
| url | https://zjdl.cbpt.cnki.net/WKE3/WebPublication/paperDigest.aspx?paperID=a2720db3-f587-4da7-be4e-84ce6539638d |
| work_keys_str_mv | AT xufeng harmonicanalysisofmultiplexrectifiercircuitsbasedondioderectifiersforoffshorewindfarms AT caowenbin harmonicanalysisofmultiplexrectifiercircuitsbasedondioderectifiersforoffshorewindfarms AT qianzhengxu harmonicanalysisofmultiplexrectifiercircuitsbasedondioderectifiersforoffshorewindfarms AT huangxiaoming harmonicanalysisofmultiplexrectifiercircuitsbasedondioderectifiersforoffshorewindfarms AT liangpeng harmonicanalysisofmultiplexrectifiercircuitsbasedondioderectifiersforoffshorewindfarms AT zhangzheren harmonicanalysisofmultiplexrectifiercircuitsbasedondioderectifiersforoffshorewindfarms AT xuzheng harmonicanalysisofmultiplexrectifiercircuitsbasedondioderectifiersforoffshorewindfarms |