Accuracy of additive and subtractive hybrid fabrication of complete-arch implant titanium frameworks

Objective To evaluate the difference in accuracy of edentulous titanium implant frameworks fabricated using subtractive and additive-subtractive hybrid fabrication techniques. Methods Implant frameworks for a maxillary edentulous jaw model with 6 implants were designed using design software(EXOCAD)...

Full description

Saved in:
Bibliographic Details
Main Author: WANG Han, HU Jian, LI Lin
Format: Article
Language:zho
Published: Editorial Office of Stomatology 2024-12-01
Series:Kouqiang yixue
Subjects:
Online Access:https://www.stomatology.cn/fileup/1003-9872/PDF/1735180953920-1435824324.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841542592463896576
author WANG Han, HU Jian, LI Lin
author_facet WANG Han, HU Jian, LI Lin
author_sort WANG Han, HU Jian, LI Lin
collection DOAJ
description Objective To evaluate the difference in accuracy of edentulous titanium implant frameworks fabricated using subtractive and additive-subtractive hybrid fabrication techniques. Methods Implant frameworks for a maxillary edentulous jaw model with 6 implants were designed using design software(EXOCAD) and exported as STL files. Five titanium implant frameworks were fabricated using subtractive manufacturing(SM) and additive-subtractive hybrid manufacturing(AM-SM) techniques, respectively. The 3D coordinates of the center points of the upper and lower planes of each implant abutment-prosthesis interface were obtained by using a coordinate measuring machine, and were “best-fit-aligned” to the original STL files in a specific software to obtain the linear deviation of the center points of the upper and lower planes of each interface in the x, y, and z axes, and the 3D deviation of each implant abutment-prosthesis interface. The centroid coordinates were imported into a reverse-measurement software(Geomagic Control X) and the angular deviation of each interface was calculated by creating “line features”. Statistical tests were performed using Kruskal-Wallis, ManneWhitney U, and one-way ANOVA(α=0.05). Results Between the differences in the implant abutment-prosthesis interfaces of the two fabrication methods, there was no statistical difference in the linear deviation on the x, y, and z axes of each interface and the 3D deviation and angular deviation of the interface(P>0.05), and the deviation values were within the clinically acceptable range. There were statistically significant differences in the 3D deviation between the different implant sites of the edentulous implant frameworks in both techniques. Conclusion Fabrication techniques do not affect the accuracy of the implant abutment-prosthesis interface. The accuracy of edentulous fixed implant frameworks fabricated by additive-subtractive hybrid fabrication techniques is within the clinically acceptable range. The implant site has a certain influence on the accuracy of the implant framework.
format Article
id doaj-art-e6092c4c10144796af99e71fee94389f
institution Kabale University
issn 1003-9872
language zho
publishDate 2024-12-01
publisher Editorial Office of Stomatology
record_format Article
series Kouqiang yixue
spelling doaj-art-e6092c4c10144796af99e71fee94389f2025-01-14T01:01:06ZzhoEditorial Office of StomatologyKouqiang yixue1003-98722024-12-01441291792210.13591/j.cnki.kqyx.2024.12.007Accuracy of additive and subtractive hybrid fabrication of complete-arch implant titanium frameworksWANG Han, HU Jian, LI Lin0Department of Prosthodontics, The Affiliated Stomatological Hospital of Nanjing Medical University, Jiangsu Province Key Laboratory of Oral Diseases, Jiangsu Province Engineering Research Center of Stomatological Translational Medicine, Nanjing 210029, ChinaObjective To evaluate the difference in accuracy of edentulous titanium implant frameworks fabricated using subtractive and additive-subtractive hybrid fabrication techniques. Methods Implant frameworks for a maxillary edentulous jaw model with 6 implants were designed using design software(EXOCAD) and exported as STL files. Five titanium implant frameworks were fabricated using subtractive manufacturing(SM) and additive-subtractive hybrid manufacturing(AM-SM) techniques, respectively. The 3D coordinates of the center points of the upper and lower planes of each implant abutment-prosthesis interface were obtained by using a coordinate measuring machine, and were “best-fit-aligned” to the original STL files in a specific software to obtain the linear deviation of the center points of the upper and lower planes of each interface in the x, y, and z axes, and the 3D deviation of each implant abutment-prosthesis interface. The centroid coordinates were imported into a reverse-measurement software(Geomagic Control X) and the angular deviation of each interface was calculated by creating “line features”. Statistical tests were performed using Kruskal-Wallis, ManneWhitney U, and one-way ANOVA(α=0.05). Results Between the differences in the implant abutment-prosthesis interfaces of the two fabrication methods, there was no statistical difference in the linear deviation on the x, y, and z axes of each interface and the 3D deviation and angular deviation of the interface(P>0.05), and the deviation values were within the clinically acceptable range. There were statistically significant differences in the 3D deviation between the different implant sites of the edentulous implant frameworks in both techniques. Conclusion Fabrication techniques do not affect the accuracy of the implant abutment-prosthesis interface. The accuracy of edentulous fixed implant frameworks fabricated by additive-subtractive hybrid fabrication techniques is within the clinically acceptable range. The implant site has a certain influence on the accuracy of the implant framework.https://www.stomatology.cn/fileup/1003-9872/PDF/1735180953920-1435824324.pdf|edentulous implant|3d printing|subtractive manufacturing|additive manufacturing|implant framework
spellingShingle WANG Han, HU Jian, LI Lin
Accuracy of additive and subtractive hybrid fabrication of complete-arch implant titanium frameworks
Kouqiang yixue
|edentulous implant|3d printing|subtractive manufacturing|additive manufacturing|implant framework
title Accuracy of additive and subtractive hybrid fabrication of complete-arch implant titanium frameworks
title_full Accuracy of additive and subtractive hybrid fabrication of complete-arch implant titanium frameworks
title_fullStr Accuracy of additive and subtractive hybrid fabrication of complete-arch implant titanium frameworks
title_full_unstemmed Accuracy of additive and subtractive hybrid fabrication of complete-arch implant titanium frameworks
title_short Accuracy of additive and subtractive hybrid fabrication of complete-arch implant titanium frameworks
title_sort accuracy of additive and subtractive hybrid fabrication of complete arch implant titanium frameworks
topic |edentulous implant|3d printing|subtractive manufacturing|additive manufacturing|implant framework
url https://www.stomatology.cn/fileup/1003-9872/PDF/1735180953920-1435824324.pdf
work_keys_str_mv AT wanghanhujianlilin accuracyofadditiveandsubtractivehybridfabricationofcompletearchimplanttitaniumframeworks