Repeatability of RRate measurements in children during triage in two Ugandan hospitals.

Pneumonia is the leading cause of death in children globally. In low- and middle-income countries (LMICs) pneumonia diagnosis relies on accurate assessment of respiratory rate, which can be unreliable when completed by nurses with less-advanced training. To inform more accurate measurements, we inve...

Full description

Saved in:
Bibliographic Details
Main Authors: Ahmad Asdo, Alishah Mawji, Isaac Omara, Ivan Aine Aye Ishebukara, Clare Komugisha, Stefanie K Novakowski, Yashodani Pillay, Matthew O Wiens, Samuel Akech, Florence Oyella, Abner Tagoola, Niranjan Kissoon, John Mark Ansermino, Dustin Dunsmuir
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2025-01-01
Series:PLOS Global Public Health
Online Access:https://doi.org/10.1371/journal.pgph.0003097
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841533128726806528
author Ahmad Asdo
Alishah Mawji
Isaac Omara
Ivan Aine Aye Ishebukara
Clare Komugisha
Stefanie K Novakowski
Yashodani Pillay
Matthew O Wiens
Samuel Akech
Florence Oyella
Abner Tagoola
Niranjan Kissoon
John Mark Ansermino
Dustin Dunsmuir
author_facet Ahmad Asdo
Alishah Mawji
Isaac Omara
Ivan Aine Aye Ishebukara
Clare Komugisha
Stefanie K Novakowski
Yashodani Pillay
Matthew O Wiens
Samuel Akech
Florence Oyella
Abner Tagoola
Niranjan Kissoon
John Mark Ansermino
Dustin Dunsmuir
author_sort Ahmad Asdo
collection DOAJ
description Pneumonia is the leading cause of death in children globally. In low- and middle-income countries (LMICs) pneumonia diagnosis relies on accurate assessment of respiratory rate, which can be unreliable when completed by nurses with less-advanced training. To inform more accurate measurements, we investigate the repeatability of the RRate app used by nurses in Ugandan district hospitals. This secondary analysis included 3,679 children aged 0-5 years. The dataset had two sequential measurements of respiratory rate collected by 14 nurses using the RRate app. We measured agreement between respiratory rate observations while indicating observations' clustering around WHO fast-breathing thresholds. WHO thresholds are 60 breaths per minute (bpm) for under two months (Age-1), 50 bpm for two to 12 months (Age-2), and 40 bpm for 12.1 to 60 months (Age-3). We assessed the repeatability of the paired measurements per user through the Intraclass Correlation Coefficient (ICC) and calculated an overall ICC value. The respiratory rate measurement took less than 15 seconds for 7,277 (98.9%) of the measurements. Despite respiratory rates clustering around WHO thresholds, breathing classification based on the thresholds (Fast vs normal) was altered between sequential measurements in only 12.6% of children. The mean (SD) respiratory rate by age group was 60 (13.1) bpm for Age-1, 49 (11.9) bpm for Age-2, and 38 (10.1) for Age-3, and the bias (Limits of Agreements) were 0.3 (-10.8-11.3) bpm, 0.4 (-8.5-9.3) bpm, and 0.1 (-6.8, 7.0) bpm for Age-1, Age-2, and Age-3 respectively. The repeatability of the paired respiratory rate measurements was high, with an ICC ≥ 90% for 12 of 14 users and an overall ICC value (95% CI) of 0.95 (0.94-0.95). The RRate measurements were efficient and repeatable. The simplicity, repeatability, and efficiency support its usage in LMICs healthcare facilities, and endorses a more widespread clinical adoption.
format Article
id doaj-art-e278a101d8974b7897ae4621fa8e03d9
institution Kabale University
issn 2767-3375
language English
publishDate 2025-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLOS Global Public Health
spelling doaj-art-e278a101d8974b7897ae4621fa8e03d92025-01-17T05:49:10ZengPublic Library of Science (PLoS)PLOS Global Public Health2767-33752025-01-0151e000309710.1371/journal.pgph.0003097Repeatability of RRate measurements in children during triage in two Ugandan hospitals.Ahmad AsdoAlishah MawjiIsaac OmaraIvan Aine Aye IshebukaraClare KomugishaStefanie K NovakowskiYashodani PillayMatthew O WiensSamuel AkechFlorence OyellaAbner TagoolaNiranjan KissoonJohn Mark AnserminoDustin DunsmuirPneumonia is the leading cause of death in children globally. In low- and middle-income countries (LMICs) pneumonia diagnosis relies on accurate assessment of respiratory rate, which can be unreliable when completed by nurses with less-advanced training. To inform more accurate measurements, we investigate the repeatability of the RRate app used by nurses in Ugandan district hospitals. This secondary analysis included 3,679 children aged 0-5 years. The dataset had two sequential measurements of respiratory rate collected by 14 nurses using the RRate app. We measured agreement between respiratory rate observations while indicating observations' clustering around WHO fast-breathing thresholds. WHO thresholds are 60 breaths per minute (bpm) for under two months (Age-1), 50 bpm for two to 12 months (Age-2), and 40 bpm for 12.1 to 60 months (Age-3). We assessed the repeatability of the paired measurements per user through the Intraclass Correlation Coefficient (ICC) and calculated an overall ICC value. The respiratory rate measurement took less than 15 seconds for 7,277 (98.9%) of the measurements. Despite respiratory rates clustering around WHO thresholds, breathing classification based on the thresholds (Fast vs normal) was altered between sequential measurements in only 12.6% of children. The mean (SD) respiratory rate by age group was 60 (13.1) bpm for Age-1, 49 (11.9) bpm for Age-2, and 38 (10.1) for Age-3, and the bias (Limits of Agreements) were 0.3 (-10.8-11.3) bpm, 0.4 (-8.5-9.3) bpm, and 0.1 (-6.8, 7.0) bpm for Age-1, Age-2, and Age-3 respectively. The repeatability of the paired respiratory rate measurements was high, with an ICC ≥ 90% for 12 of 14 users and an overall ICC value (95% CI) of 0.95 (0.94-0.95). The RRate measurements were efficient and repeatable. The simplicity, repeatability, and efficiency support its usage in LMICs healthcare facilities, and endorses a more widespread clinical adoption.https://doi.org/10.1371/journal.pgph.0003097
spellingShingle Ahmad Asdo
Alishah Mawji
Isaac Omara
Ivan Aine Aye Ishebukara
Clare Komugisha
Stefanie K Novakowski
Yashodani Pillay
Matthew O Wiens
Samuel Akech
Florence Oyella
Abner Tagoola
Niranjan Kissoon
John Mark Ansermino
Dustin Dunsmuir
Repeatability of RRate measurements in children during triage in two Ugandan hospitals.
PLOS Global Public Health
title Repeatability of RRate measurements in children during triage in two Ugandan hospitals.
title_full Repeatability of RRate measurements in children during triage in two Ugandan hospitals.
title_fullStr Repeatability of RRate measurements in children during triage in two Ugandan hospitals.
title_full_unstemmed Repeatability of RRate measurements in children during triage in two Ugandan hospitals.
title_short Repeatability of RRate measurements in children during triage in two Ugandan hospitals.
title_sort repeatability of rrate measurements in children during triage in two ugandan hospitals
url https://doi.org/10.1371/journal.pgph.0003097
work_keys_str_mv AT ahmadasdo repeatabilityofrratemeasurementsinchildrenduringtriageintwougandanhospitals
AT alishahmawji repeatabilityofrratemeasurementsinchildrenduringtriageintwougandanhospitals
AT isaacomara repeatabilityofrratemeasurementsinchildrenduringtriageintwougandanhospitals
AT ivanaineayeishebukara repeatabilityofrratemeasurementsinchildrenduringtriageintwougandanhospitals
AT clarekomugisha repeatabilityofrratemeasurementsinchildrenduringtriageintwougandanhospitals
AT stefanieknovakowski repeatabilityofrratemeasurementsinchildrenduringtriageintwougandanhospitals
AT yashodanipillay repeatabilityofrratemeasurementsinchildrenduringtriageintwougandanhospitals
AT matthewowiens repeatabilityofrratemeasurementsinchildrenduringtriageintwougandanhospitals
AT samuelakech repeatabilityofrratemeasurementsinchildrenduringtriageintwougandanhospitals
AT florenceoyella repeatabilityofrratemeasurementsinchildrenduringtriageintwougandanhospitals
AT abnertagoola repeatabilityofrratemeasurementsinchildrenduringtriageintwougandanhospitals
AT niranjankissoon repeatabilityofrratemeasurementsinchildrenduringtriageintwougandanhospitals
AT johnmarkansermino repeatabilityofrratemeasurementsinchildrenduringtriageintwougandanhospitals
AT dustindunsmuir repeatabilityofrratemeasurementsinchildrenduringtriageintwougandanhospitals