An Evaluation of Light Quantity and Quality in Reading Rooms, and Suggestions for Amendments; the Case of Shahid Beheshti University libraries

Daylight reception in built environments is one of the main performance indicators for the quality of life. This is even more important in certain spaces such as study rooms. There are a variety of measurement indices for assessing daylight. The present paper assesses daylight availability and visua...

Full description

Saved in:
Bibliographic Details
Main Authors: n ima Forouzandeh Shahraki, Haanieh Ahmadi Joushghani, Haanieh Nourkojouri, zahra zomorodian
Format: Article
Language:fas
Published: Shahid Beheshti University 2021-12-01
Series:صفه
Subjects:
Online Access:https://soffeh.sbu.ac.ir/article_101847_7205bc9e02031fa0095638e45ad7676e.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1846168510455087104
author n ima Forouzandeh Shahraki
Haanieh Ahmadi Joushghani
Haanieh Nourkojouri
zahra zomorodian
author_facet n ima Forouzandeh Shahraki
Haanieh Ahmadi Joushghani
Haanieh Nourkojouri
zahra zomorodian
author_sort n ima Forouzandeh Shahraki
collection DOAJ
description Daylight reception in built environments is one of the main performance indicators for the quality of life. This is even more important in certain spaces such as study rooms. There are a variety of measurement indices for assessing daylight. The present paper assesses daylight availability and visual comfort in seven libraries at Shahid Beheshti University, Tehran, through software simulation using DIVA. The corresponding performance indices are then evaluated against recommended values in national and international standards. In order to improve visual conditions a series of solutions are proposed, and then applied in studied cases, to demonstrate their effectiveness in improving the quantity and quality of daylight.  The simulated models are tested for validity, and used in order to study their respective effect in sufficiency and distribution of light, visual comfort and required energy. In the end, a series of suggestions are made in each case based on simulation results and costs. According to initial assessments, the main problem was low levels of daylight availability in five cases, and high levels in another. The Useful Daylight Illuminance index (UDI300-3000) are increased from 6–59% to 24–100% by implementing improvement strategies. In addition, the lighting energy in the studied spaces, have been improved by 4–58%. The most effective improvement measures areincreasing the reflectance of walls and ceilings (changing colours),using skylight, andincreasing the light transmittance of windows by substituting them with more transparent windows or by regularly cleaning them.
format Article
id doaj-art-dffa11e22bcb41e0881dbeac4694c880
institution Kabale University
issn 1683-870X
2645-5900
language fas
publishDate 2021-12-01
publisher Shahid Beheshti University
record_format Article
series صفه
spelling doaj-art-dffa11e22bcb41e0881dbeac4694c8802024-11-13T20:51:15ZfasShahid Beheshti Universityصفه1683-870X2645-59002021-12-01314314810.52547/sofeh.31.4.31101847An Evaluation of Light Quantity and Quality in Reading Rooms, and Suggestions for Amendments; the Case of Shahid Beheshti University librariesn ima Forouzandeh Shahraki0Haanieh Ahmadi Joushghani1Haanieh Nourkojouri2zahra zomorodian3MSc, Architecture and Energy, Faculty of Architecture and Urban Planning, Shahid Beheshti UniversityMSc, Architecture and Energy, Faculty of Architecture and Urban Planning, Shahid Beheshti UniversityMSc, Architecture and Energy, Faculty of Architecture and Urban Planning, Shahid Beheshti UniversityAssistant Professor, Faculty of Architecture and Urban Planning, Shahid Beheshti UniversityDaylight reception in built environments is one of the main performance indicators for the quality of life. This is even more important in certain spaces such as study rooms. There are a variety of measurement indices for assessing daylight. The present paper assesses daylight availability and visual comfort in seven libraries at Shahid Beheshti University, Tehran, through software simulation using DIVA. The corresponding performance indices are then evaluated against recommended values in national and international standards. In order to improve visual conditions a series of solutions are proposed, and then applied in studied cases, to demonstrate their effectiveness in improving the quantity and quality of daylight.  The simulated models are tested for validity, and used in order to study their respective effect in sufficiency and distribution of light, visual comfort and required energy. In the end, a series of suggestions are made in each case based on simulation results and costs. According to initial assessments, the main problem was low levels of daylight availability in five cases, and high levels in another. The Useful Daylight Illuminance index (UDI300-3000) are increased from 6–59% to 24–100% by implementing improvement strategies. In addition, the lighting energy in the studied spaces, have been improved by 4–58%. The most effective improvement measures areincreasing the reflectance of walls and ceilings (changing colours),using skylight, andincreasing the light transmittance of windows by substituting them with more transparent windows or by regularly cleaning them.https://soffeh.sbu.ac.ir/article_101847_7205bc9e02031fa0095638e45ad7676e.pdfdaylightglarelibraryvisual comfort
spellingShingle n ima Forouzandeh Shahraki
Haanieh Ahmadi Joushghani
Haanieh Nourkojouri
zahra zomorodian
An Evaluation of Light Quantity and Quality in Reading Rooms, and Suggestions for Amendments; the Case of Shahid Beheshti University libraries
صفه
daylight
glare
library
visual comfort
title An Evaluation of Light Quantity and Quality in Reading Rooms, and Suggestions for Amendments; the Case of Shahid Beheshti University libraries
title_full An Evaluation of Light Quantity and Quality in Reading Rooms, and Suggestions for Amendments; the Case of Shahid Beheshti University libraries
title_fullStr An Evaluation of Light Quantity and Quality in Reading Rooms, and Suggestions for Amendments; the Case of Shahid Beheshti University libraries
title_full_unstemmed An Evaluation of Light Quantity and Quality in Reading Rooms, and Suggestions for Amendments; the Case of Shahid Beheshti University libraries
title_short An Evaluation of Light Quantity and Quality in Reading Rooms, and Suggestions for Amendments; the Case of Shahid Beheshti University libraries
title_sort evaluation of light quantity and quality in reading rooms and suggestions for amendments the case of shahid beheshti university libraries
topic daylight
glare
library
visual comfort
url https://soffeh.sbu.ac.ir/article_101847_7205bc9e02031fa0095638e45ad7676e.pdf
work_keys_str_mv AT nimaforouzandehshahraki anevaluationoflightquantityandqualityinreadingroomsandsuggestionsforamendmentsthecaseofshahidbeheshtiuniversitylibraries
AT haaniehahmadijoushghani anevaluationoflightquantityandqualityinreadingroomsandsuggestionsforamendmentsthecaseofshahidbeheshtiuniversitylibraries
AT haaniehnourkojouri anevaluationoflightquantityandqualityinreadingroomsandsuggestionsforamendmentsthecaseofshahidbeheshtiuniversitylibraries
AT zahrazomorodian anevaluationoflightquantityandqualityinreadingroomsandsuggestionsforamendmentsthecaseofshahidbeheshtiuniversitylibraries
AT nimaforouzandehshahraki evaluationoflightquantityandqualityinreadingroomsandsuggestionsforamendmentsthecaseofshahidbeheshtiuniversitylibraries
AT haaniehahmadijoushghani evaluationoflightquantityandqualityinreadingroomsandsuggestionsforamendmentsthecaseofshahidbeheshtiuniversitylibraries
AT haaniehnourkojouri evaluationoflightquantityandqualityinreadingroomsandsuggestionsforamendmentsthecaseofshahidbeheshtiuniversitylibraries
AT zahrazomorodian evaluationoflightquantityandqualityinreadingroomsandsuggestionsforamendmentsthecaseofshahidbeheshtiuniversitylibraries