High-Temporal-Resolution Corrosion Monitoring in Fluctuating-Temperature Environments with an Improved Electrical Resistance Sensor

The electrical resistance (ER) method is widely used for atmospheric corrosion measurements and can be used to measure the corrosion rate accurately. However, severe errors occur in environments with temperature fluctuations, such as areas exposed to solar radiation, preventing accurate temporal cor...

Full description

Saved in:
Bibliographic Details
Main Author: Mao Takeyama
Format: Article
Language:English
Published: MDPI AG 2025-01-01
Series:Sensors
Subjects:
Online Access:https://www.mdpi.com/1424-8220/25/1/268
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The electrical resistance (ER) method is widely used for atmospheric corrosion measurements and can be used to measure the corrosion rate accurately. However, severe errors occur in environments with temperature fluctuations, such as areas exposed to solar radiation, preventing accurate temporal corrosion rate measurement. To decrease the error, we developed an improved sensor composed of a reference metal film and an overlaid sensor metal film to cancel temperature differences between them. The improved sensor was compared with an existing sensor product in outdoor monitoring experiments. The spike-like error during the daytime was successfully reduced. Furthermore, by utilizing a data-filtering process, we measured the corrosion rate every hour. Hourly corrosion rate measurements were difficult when the average daily corrosion rate was less than 50 µm/year under conditions of 0.05 g/m<sup>2</sup> salt. Observations showed a strong correlation between corrosion rate and sensor surface humidity. In the future, this method will make it possible to study the relationship between the atmospheric corrosion rate and environmental changes over time.
ISSN:1424-8220