A Vegetable Oil as Heat Transfer Fluid for Parabolic Trough Collector: Dynamic Performance Analysis under Ouagadougou Climate Conditions
In this study, the thermal performance of the parabolic trough collector (PTC) has been addressed under Ouagadougou climate conditions. Thus, after developing a model, the effect of mass flow on PTC performance showed that the Jatropha curcas oil (JCO) temperature difference increases when the mass...
Saved in:
| Main Authors: | , , , , , , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
MDPI AG
2024-01-01
|
| Series: | Materials Proceedings |
| Subjects: | |
| Online Access: | https://www.mdpi.com/2673-4605/11/1/6 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1846103823084421120 |
|---|---|
| author | Boubou Bagré Sié Zacharie Kam Yomi Woro Gounkaou Makinta Boukar Ibrahim Kolawole Muritala Harouna Sani Dan Nomao Korsaga Armand Antoine Beré Tizane Daho |
| author_facet | Boubou Bagré Sié Zacharie Kam Yomi Woro Gounkaou Makinta Boukar Ibrahim Kolawole Muritala Harouna Sani Dan Nomao Korsaga Armand Antoine Beré Tizane Daho |
| author_sort | Boubou Bagré |
| collection | DOAJ |
| description | In this study, the thermal performance of the parabolic trough collector (PTC) has been addressed under Ouagadougou climate conditions. Thus, after developing a model, the effect of mass flow on PTC performance showed that the Jatropha curcas oil (JCO) temperature difference increases when the mass flow rate (<inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><mover accent="true"><mi>m</mi><mo>˙</mo></mover></semantics></math></inline-formula>) decreases while the thermal efficiency (<inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><mrow><msub><mi>η</mi><mrow><mi>t</mi><mi>h</mi></mrow></msub></mrow></semantics></math></inline-formula>) increases. For <inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><mover accent="true"><mi>m</mi><mo>˙</mo></mover></semantics></math></inline-formula> of 1 kg s<sup>−1</sup>, a collector length of 46.8 m or collection area of 230 m<sup>2</sup> is required to obtain an outlet temperature of 210 °C with an average <inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><mrow><msub><mi>η</mi><mrow><mi>t</mi><mi>h</mi></mrow></msub></mrow></semantics></math></inline-formula> of 82.69%. This paper can support the decision for a demonstration plant implementation regarding JCO use in the CSP plant. |
| format | Article |
| id | doaj-art-dc7b45e7c8b1481c90b2f44a01acbbdb |
| institution | Kabale University |
| issn | 2673-4605 |
| language | English |
| publishDate | 2024-01-01 |
| publisher | MDPI AG |
| record_format | Article |
| series | Materials Proceedings |
| spelling | doaj-art-dc7b45e7c8b1481c90b2f44a01acbbdb2024-12-27T14:37:50ZengMDPI AGMaterials Proceedings2673-46052024-01-01111610.3390/materproc2022011006A Vegetable Oil as Heat Transfer Fluid for Parabolic Trough Collector: Dynamic Performance Analysis under Ouagadougou Climate ConditionsBoubou Bagré0Sié Zacharie Kam1Yomi Woro Gounkaou2Makinta Boukar3Ibrahim Kolawole Muritala4Harouna Sani Dan Nomao5Korsaga Armand6Antoine Beré7Tizane Daho8Doctoral Research Programme in Climate Change and Energy, Department of Physics, Université Abdou Moumouni (WASCAL-DRP CCE), Niamey 10662, NigerLaboratoire de Physique et de Chimie de l’Environnement, Université Joseph KI-ZERBO, Ouagadougou 03 BP 7021, Burkina FasoLaboratoire de Physique et de Chimie de l’Environnement, Université Joseph KI-ZERBO, Ouagadougou 03 BP 7021, Burkina FasoDoctoral Research Programme in Climate Change and Energy, Department of Physics, Université Abdou Moumouni (WASCAL-DRP CCE), Niamey 10662, NigerInstitute of Low-Carbon Industrial Processes, German Aerospace Center (DLR), 02763 Zittau, GermanyLaboratoire d’Energétique et d’Electronique, d’Electrotechnique, d’Automatique, d’Informatique Industrielle (LAERT-LA2EI), Université Abdou Moumouni, Niamey 10662, NigerLaboratoire de Physique et de Chimie de l’Environnement, Université Joseph KI-ZERBO, Ouagadougou 03 BP 7021, Burkina FasoLaboratoire de Physique et de Chimie de l’Environnement, Université Joseph KI-ZERBO, Ouagadougou 03 BP 7021, Burkina FasoLaboratoire de Physique et de Chimie de l’Environnement, Université Joseph KI-ZERBO, Ouagadougou 03 BP 7021, Burkina FasoIn this study, the thermal performance of the parabolic trough collector (PTC) has been addressed under Ouagadougou climate conditions. Thus, after developing a model, the effect of mass flow on PTC performance showed that the Jatropha curcas oil (JCO) temperature difference increases when the mass flow rate (<inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><mover accent="true"><mi>m</mi><mo>˙</mo></mover></semantics></math></inline-formula>) decreases while the thermal efficiency (<inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><mrow><msub><mi>η</mi><mrow><mi>t</mi><mi>h</mi></mrow></msub></mrow></semantics></math></inline-formula>) increases. For <inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><mover accent="true"><mi>m</mi><mo>˙</mo></mover></semantics></math></inline-formula> of 1 kg s<sup>−1</sup>, a collector length of 46.8 m or collection area of 230 m<sup>2</sup> is required to obtain an outlet temperature of 210 °C with an average <inline-formula><math xmlns="http://www.w3.org/1998/Math/MathML" display="inline"><semantics><mrow><msub><mi>η</mi><mrow><mi>t</mi><mi>h</mi></mrow></msub></mrow></semantics></math></inline-formula> of 82.69%. This paper can support the decision for a demonstration plant implementation regarding JCO use in the CSP plant.https://www.mdpi.com/2673-4605/11/1/6collectorvegetable oilthermal performance |
| spellingShingle | Boubou Bagré Sié Zacharie Kam Yomi Woro Gounkaou Makinta Boukar Ibrahim Kolawole Muritala Harouna Sani Dan Nomao Korsaga Armand Antoine Beré Tizane Daho A Vegetable Oil as Heat Transfer Fluid for Parabolic Trough Collector: Dynamic Performance Analysis under Ouagadougou Climate Conditions Materials Proceedings collector vegetable oil thermal performance |
| title | A Vegetable Oil as Heat Transfer Fluid for Parabolic Trough Collector: Dynamic Performance Analysis under Ouagadougou Climate Conditions |
| title_full | A Vegetable Oil as Heat Transfer Fluid for Parabolic Trough Collector: Dynamic Performance Analysis under Ouagadougou Climate Conditions |
| title_fullStr | A Vegetable Oil as Heat Transfer Fluid for Parabolic Trough Collector: Dynamic Performance Analysis under Ouagadougou Climate Conditions |
| title_full_unstemmed | A Vegetable Oil as Heat Transfer Fluid for Parabolic Trough Collector: Dynamic Performance Analysis under Ouagadougou Climate Conditions |
| title_short | A Vegetable Oil as Heat Transfer Fluid for Parabolic Trough Collector: Dynamic Performance Analysis under Ouagadougou Climate Conditions |
| title_sort | vegetable oil as heat transfer fluid for parabolic trough collector dynamic performance analysis under ouagadougou climate conditions |
| topic | collector vegetable oil thermal performance |
| url | https://www.mdpi.com/2673-4605/11/1/6 |
| work_keys_str_mv | AT bouboubagre avegetableoilasheattransferfluidforparabolictroughcollectordynamicperformanceanalysisunderouagadougouclimateconditions AT siezachariekam avegetableoilasheattransferfluidforparabolictroughcollectordynamicperformanceanalysisunderouagadougouclimateconditions AT yomiworogounkaou avegetableoilasheattransferfluidforparabolictroughcollectordynamicperformanceanalysisunderouagadougouclimateconditions AT makintaboukar avegetableoilasheattransferfluidforparabolictroughcollectordynamicperformanceanalysisunderouagadougouclimateconditions AT ibrahimkolawolemuritala avegetableoilasheattransferfluidforparabolictroughcollectordynamicperformanceanalysisunderouagadougouclimateconditions AT harounasanidannomao avegetableoilasheattransferfluidforparabolictroughcollectordynamicperformanceanalysisunderouagadougouclimateconditions AT korsagaarmand avegetableoilasheattransferfluidforparabolictroughcollectordynamicperformanceanalysisunderouagadougouclimateconditions AT antoinebere avegetableoilasheattransferfluidforparabolictroughcollectordynamicperformanceanalysisunderouagadougouclimateconditions AT tizanedaho avegetableoilasheattransferfluidforparabolictroughcollectordynamicperformanceanalysisunderouagadougouclimateconditions AT bouboubagre vegetableoilasheattransferfluidforparabolictroughcollectordynamicperformanceanalysisunderouagadougouclimateconditions AT siezachariekam vegetableoilasheattransferfluidforparabolictroughcollectordynamicperformanceanalysisunderouagadougouclimateconditions AT yomiworogounkaou vegetableoilasheattransferfluidforparabolictroughcollectordynamicperformanceanalysisunderouagadougouclimateconditions AT makintaboukar vegetableoilasheattransferfluidforparabolictroughcollectordynamicperformanceanalysisunderouagadougouclimateconditions AT ibrahimkolawolemuritala vegetableoilasheattransferfluidforparabolictroughcollectordynamicperformanceanalysisunderouagadougouclimateconditions AT harounasanidannomao vegetableoilasheattransferfluidforparabolictroughcollectordynamicperformanceanalysisunderouagadougouclimateconditions AT korsagaarmand vegetableoilasheattransferfluidforparabolictroughcollectordynamicperformanceanalysisunderouagadougouclimateconditions AT antoinebere vegetableoilasheattransferfluidforparabolictroughcollectordynamicperformanceanalysisunderouagadougouclimateconditions AT tizanedaho vegetableoilasheattransferfluidforparabolictroughcollectordynamicperformanceanalysisunderouagadougouclimateconditions |