Transmission Design and Simulation Analysis of Lower Exoskeleton Rehabilitation Device

The hydraulic lower exoskeleton rehabilitation device is proposed to solve the problem of patient lying on the bed can’t walk and the aged leg rehabilitation training. Two kinds of transmission schemes are put forward as its main transmission mechanism,which are crank- slider mechanism and slider- r...

Full description

Saved in:
Bibliographic Details
Main Authors: Hu Qingming, Guo Qiang, Guo Jianhua
Format: Article
Language:zho
Published: Editorial Office of Journal of Mechanical Transmission 2016-01-01
Series:Jixie chuandong
Subjects:
Online Access:http://www.jxcd.net.cn/thesisDetails#10.16578/j.issn.1004.2539.2016.07.023
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841547937986904064
author Hu Qingming
Guo Qiang
Guo Jianhua
author_facet Hu Qingming
Guo Qiang
Guo Jianhua
author_sort Hu Qingming
collection DOAJ
description The hydraulic lower exoskeleton rehabilitation device is proposed to solve the problem of patient lying on the bed can’t walk and the aged leg rehabilitation training. Two kinds of transmission schemes are put forward as its main transmission mechanism,which are crank- slider mechanism and slider- rocker mechanism. With the main construction member motion analysis of the crank- slider mechanism and slider- rocker mechanism,the main technical parameters are obtained. And the displacement,velocity and acceleration of the components are acquired and compared simultaneously. Then the slider- rocker mechanism is determined as the main transmission mechanism of the hydraulic lower exoskeleton rehabilitation device. Finally,the three dimensional assembly model of the legs rehabilitation device is established with Solid Works,and the simulation and mechanics analysis are conducted. The results show that the proposed hydraulic legs rehabilitation device can achieve the expected movement purpose and meet the requirements of rehabilitation training.
format Article
id doaj-art-dc5ec8243ab64fc4b33be6da822fb2a5
institution Kabale University
issn 1004-2539
language zho
publishDate 2016-01-01
publisher Editorial Office of Journal of Mechanical Transmission
record_format Article
series Jixie chuandong
spelling doaj-art-dc5ec8243ab64fc4b33be6da822fb2a52025-01-10T14:16:30ZzhoEditorial Office of Journal of Mechanical TransmissionJixie chuandong1004-25392016-01-014010711029924748Transmission Design and Simulation Analysis of Lower Exoskeleton Rehabilitation DeviceHu QingmingGuo QiangGuo JianhuaThe hydraulic lower exoskeleton rehabilitation device is proposed to solve the problem of patient lying on the bed can’t walk and the aged leg rehabilitation training. Two kinds of transmission schemes are put forward as its main transmission mechanism,which are crank- slider mechanism and slider- rocker mechanism. With the main construction member motion analysis of the crank- slider mechanism and slider- rocker mechanism,the main technical parameters are obtained. And the displacement,velocity and acceleration of the components are acquired and compared simultaneously. Then the slider- rocker mechanism is determined as the main transmission mechanism of the hydraulic lower exoskeleton rehabilitation device. Finally,the three dimensional assembly model of the legs rehabilitation device is established with Solid Works,and the simulation and mechanics analysis are conducted. The results show that the proposed hydraulic legs rehabilitation device can achieve the expected movement purpose and meet the requirements of rehabilitation training.http://www.jxcd.net.cn/thesisDetails#10.16578/j.issn.1004.2539.2016.07.023Rehabilitation trainingCrank-slider mechanismSlider-rocker mechanismSimulation analysis
spellingShingle Hu Qingming
Guo Qiang
Guo Jianhua
Transmission Design and Simulation Analysis of Lower Exoskeleton Rehabilitation Device
Jixie chuandong
Rehabilitation training
Crank-slider mechanism
Slider-rocker mechanism
Simulation analysis
title Transmission Design and Simulation Analysis of Lower Exoskeleton Rehabilitation Device
title_full Transmission Design and Simulation Analysis of Lower Exoskeleton Rehabilitation Device
title_fullStr Transmission Design and Simulation Analysis of Lower Exoskeleton Rehabilitation Device
title_full_unstemmed Transmission Design and Simulation Analysis of Lower Exoskeleton Rehabilitation Device
title_short Transmission Design and Simulation Analysis of Lower Exoskeleton Rehabilitation Device
title_sort transmission design and simulation analysis of lower exoskeleton rehabilitation device
topic Rehabilitation training
Crank-slider mechanism
Slider-rocker mechanism
Simulation analysis
url http://www.jxcd.net.cn/thesisDetails#10.16578/j.issn.1004.2539.2016.07.023
work_keys_str_mv AT huqingming transmissiondesignandsimulationanalysisoflowerexoskeletonrehabilitationdevice
AT guoqiang transmissiondesignandsimulationanalysisoflowerexoskeletonrehabilitationdevice
AT guojianhua transmissiondesignandsimulationanalysisoflowerexoskeletonrehabilitationdevice