PLL-less Robust DeadBeat-response Direct Power Control of Grid-Tie Three-Phase Inverters

A new type of PLL-less Direct Power Control with robust implementation and deadbeat response is presented for grid-tie inverters. In this work a novel positive sequence detector is also implemented which ensures the elimination of perturbation at the output current due to harmonics content. The cont...

Full description

Saved in:
Bibliographic Details
Main Authors: J.R. Fischer, S.A. González, I. Carugati, M.G. Judewicz, D.O. Carrica
Format: Article
Language:Spanish
Published: Universitat Politècnica de València 2015-04-01
Series:Revista Iberoamericana de Automática e Informática Industrial RIAI
Subjects:
Online Access:https://polipapers.upv.es/index.php/RIAI/article/view/9393
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A new type of PLL-less Direct Power Control with robust implementation and deadbeat response is presented for grid-tie inverters. In this work a novel positive sequence detector is also implemented which ensures the elimination of perturbation at the output current due to harmonics content. The control algorithm has an intrinsic synchronization scheme which avoids an additional three-phase PLL. This maximizes the response time and power tracking achieving precise power step reference change in less than 200 μs. The results obtained are shown with both simulations and experiential results in a 15kW three-phase inverter that verifies the performance of the proposed controller, yielding low-harmonics output currents even in abnormal operating situations.