Preconcentration with 1-Nitroso-2-naphthol Complexes on Dowex MWC-1 Resin: Determination of Cu and Zn at Trace Level in Drinking Water Samples by ICP-AES
In this study, copper(II) and zinc(II) were quantitatively determined in drinking water using ICP-AES after preconcentration. For this purpose, the water samples were treated with 1-nitroso-2-naphthol to form metal complexes on Dowex MWC-1 resin. Prior to the sorption process, the column was treated...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2009-01-01
|
Series: | E-Journal of Chemistry |
Online Access: | http://dx.doi.org/10.1155/2009/734525 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1841524831860817920 |
---|---|
author | A. Demir Mulazimoglu I. E. Mulazimoglu E. Ozkan |
author_facet | A. Demir Mulazimoglu I. E. Mulazimoglu E. Ozkan |
author_sort | A. Demir Mulazimoglu |
collection | DOAJ |
description | In this study, copper(II) and zinc(II) were quantitatively determined in drinking water using ICP-AES after preconcentration. For this purpose, the water samples were treated with 1-nitroso-2-naphthol to form metal complexes on Dowex MWC-1 resin. Prior to the sorption process, the column was treated with a chelating resin Dowex MWC-1 and the column was prepared by passing buffer solution at different pH values. These columns were used for the transportation of water samples through the resin at the flow rate of 2.00 mL min-1. The effluents were then analyzed by ICP-AES using standard addition method. The effect of pH, amount of resin, ligand concentration and eluent type were investigated. The detection limit for Cu(II) and Zn(II) were found to be 2.78 μg L-1and 6.34 μg L-1 respectively (RSD.’s <%5).it would be concluded that the determination of copper(II) and zinc(II) in drinking water was simple, fast and repliable using this technique. |
format | Article |
id | doaj-art-d9cdcf9d33624bf0a21efcc37275a609 |
institution | Kabale University |
issn | 0973-4945 2090-9810 |
language | English |
publishDate | 2009-01-01 |
publisher | Wiley |
record_format | Article |
series | E-Journal of Chemistry |
spelling | doaj-art-d9cdcf9d33624bf0a21efcc37275a6092025-02-03T05:47:18ZengWileyE-Journal of Chemistry0973-49452090-98102009-01-01641176118010.1155/2009/734525Preconcentration with 1-Nitroso-2-naphthol Complexes on Dowex MWC-1 Resin: Determination of Cu and Zn at Trace Level in Drinking Water Samples by ICP-AESA. Demir Mulazimoglu0I. E. Mulazimoglu1E. Ozkan2Department of Chemistry, Selçuk University, 42099, Konya, TurkeyDepartment of Chemistry, Selçuk University, 42099, Konya, TurkeyDepartment of Chemistry, Selçuk University, 42099, Konya, TurkeyIn this study, copper(II) and zinc(II) were quantitatively determined in drinking water using ICP-AES after preconcentration. For this purpose, the water samples were treated with 1-nitroso-2-naphthol to form metal complexes on Dowex MWC-1 resin. Prior to the sorption process, the column was treated with a chelating resin Dowex MWC-1 and the column was prepared by passing buffer solution at different pH values. These columns were used for the transportation of water samples through the resin at the flow rate of 2.00 mL min-1. The effluents were then analyzed by ICP-AES using standard addition method. The effect of pH, amount of resin, ligand concentration and eluent type were investigated. The detection limit for Cu(II) and Zn(II) were found to be 2.78 μg L-1and 6.34 μg L-1 respectively (RSD.’s <%5).it would be concluded that the determination of copper(II) and zinc(II) in drinking water was simple, fast and repliable using this technique.http://dx.doi.org/10.1155/2009/734525 |
spellingShingle | A. Demir Mulazimoglu I. E. Mulazimoglu E. Ozkan Preconcentration with 1-Nitroso-2-naphthol Complexes on Dowex MWC-1 Resin: Determination of Cu and Zn at Trace Level in Drinking Water Samples by ICP-AES E-Journal of Chemistry |
title | Preconcentration with 1-Nitroso-2-naphthol Complexes on Dowex MWC-1 Resin: Determination of Cu and Zn at Trace Level in Drinking Water Samples by ICP-AES |
title_full | Preconcentration with 1-Nitroso-2-naphthol Complexes on Dowex MWC-1 Resin: Determination of Cu and Zn at Trace Level in Drinking Water Samples by ICP-AES |
title_fullStr | Preconcentration with 1-Nitroso-2-naphthol Complexes on Dowex MWC-1 Resin: Determination of Cu and Zn at Trace Level in Drinking Water Samples by ICP-AES |
title_full_unstemmed | Preconcentration with 1-Nitroso-2-naphthol Complexes on Dowex MWC-1 Resin: Determination of Cu and Zn at Trace Level in Drinking Water Samples by ICP-AES |
title_short | Preconcentration with 1-Nitroso-2-naphthol Complexes on Dowex MWC-1 Resin: Determination of Cu and Zn at Trace Level in Drinking Water Samples by ICP-AES |
title_sort | preconcentration with 1 nitroso 2 naphthol complexes on dowex mwc 1 resin determination of cu and zn at trace level in drinking water samples by icp aes |
url | http://dx.doi.org/10.1155/2009/734525 |
work_keys_str_mv | AT ademirmulazimoglu preconcentrationwith1nitroso2naphtholcomplexesondowexmwc1resindeterminationofcuandznattracelevelindrinkingwatersamplesbyicpaes AT iemulazimoglu preconcentrationwith1nitroso2naphtholcomplexesondowexmwc1resindeterminationofcuandznattracelevelindrinkingwatersamplesbyicpaes AT eozkan preconcentrationwith1nitroso2naphtholcomplexesondowexmwc1resindeterminationofcuandznattracelevelindrinkingwatersamplesbyicpaes |