Contact Pressures of the Posterior Heel in Lower Extremity Splints: A Biomechanical Study

Category: Basic Sciences/Biologics; Trauma Introduction/Purpose: Immobilization using lower extremity splints is a ubiquitous tool in orthopaedic care in the emergency department, operating room, and outpatient clinic settings. Prolonged use of these splints may result in skin changes or ulceration...

Full description

Saved in:
Bibliographic Details
Main Authors: Erik R. Nakken MD, Kempland C. Walley MD, Paul Talusan MD, David Walton MD, James Holmes MD
Format: Article
Language:English
Published: SAGE Publishing 2024-12-01
Series:Foot & Ankle Orthopaedics
Online Access:https://doi.org/10.1177/2473011424S00219
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1846111217885642752
author Erik R. Nakken MD
Kempland C. Walley MD
Paul Talusan MD
David Walton MD
James Holmes MD
author_facet Erik R. Nakken MD
Kempland C. Walley MD
Paul Talusan MD
David Walton MD
James Holmes MD
author_sort Erik R. Nakken MD
collection DOAJ
description Category: Basic Sciences/Biologics; Trauma Introduction/Purpose: Immobilization using lower extremity splints is a ubiquitous tool in orthopaedic care in the emergency department, operating room, and outpatient clinic settings. Prolonged use of these splints may result in skin changes or ulceration of the heel if not padded or positioned correctly. There is currently no biomechanical study in the literature measuring posterior heel contact pressure in lower extremity splints. The purpose of our study is to measure the contact pressure differences in the posterior heel with increasing layers of cotton padding, with and without the heel floating. We hypothesize that increased layers of padding will decrease contact pressure, but improvement will plateau. We predict that floating the heel will also considerably offload contact pressure. Methods: Short leg splints were applied to six limbs in three healthy subjects with an underlying pressure transducer (Tekscan I-Scan system) on the skin surface of the posterior heel. Peak contact pressures were measured after 0, 2, 4, and 6 layers of cotton padding were applied behind the heel in positions both with and without the heel freely floating. Each limb served as their own control, as pressure changes were compared to each limb’s baseline measurement (splint applied with all padding removed). Results: Over a 3-fold decrease in peak contact pressure was observed after the application of 4 or 6 layers of cotton padding. This escalated to over a 6-fold decrease with 2, 4, or 6 layers of padding while the splint was positioned with the heel freely floating. Splints with 4 and 6 layers of padding decreased heel contact pressure similarly (reduced to 29% and 28% from baseline, respectively), improved from 2 layers of padding (51% decrease from baseline). The mean contact pressure with 6 layers of padding (28% from baseline) remained higher than the mean contact pressure with 0 layers of padding with the heel floating (21% from baseline). Conclusion: Lower extremity splints with 4 or 6 layers of cotton padding provided a meaningful decrease in peak posterior heel contact pressure. The greatest decrease in heel contact pressure was observed in splints with the heel floating, even with all layers of cotton padding removed. This was more optimal than all layers of cotton padding tested. This study emphasizes the critical nature of patient counseling regarding the importance of proper splint positioning with the heel floating when at rest. Neglecting to do so may put the patient at increased risk for posterior heel skin complications.
format Article
id doaj-art-d75a03c67ce244a6a46e3e758fd19945
institution Kabale University
issn 2473-0114
language English
publishDate 2024-12-01
publisher SAGE Publishing
record_format Article
series Foot & Ankle Orthopaedics
spelling doaj-art-d75a03c67ce244a6a46e3e758fd199452024-12-23T11:04:19ZengSAGE PublishingFoot & Ankle Orthopaedics2473-01142024-12-01910.1177/2473011424S00219Contact Pressures of the Posterior Heel in Lower Extremity Splints: A Biomechanical StudyErik R. Nakken MDKempland C. Walley MDPaul Talusan MDDavid Walton MDJames Holmes MDCategory: Basic Sciences/Biologics; Trauma Introduction/Purpose: Immobilization using lower extremity splints is a ubiquitous tool in orthopaedic care in the emergency department, operating room, and outpatient clinic settings. Prolonged use of these splints may result in skin changes or ulceration of the heel if not padded or positioned correctly. There is currently no biomechanical study in the literature measuring posterior heel contact pressure in lower extremity splints. The purpose of our study is to measure the contact pressure differences in the posterior heel with increasing layers of cotton padding, with and without the heel floating. We hypothesize that increased layers of padding will decrease contact pressure, but improvement will plateau. We predict that floating the heel will also considerably offload contact pressure. Methods: Short leg splints were applied to six limbs in three healthy subjects with an underlying pressure transducer (Tekscan I-Scan system) on the skin surface of the posterior heel. Peak contact pressures were measured after 0, 2, 4, and 6 layers of cotton padding were applied behind the heel in positions both with and without the heel freely floating. Each limb served as their own control, as pressure changes were compared to each limb’s baseline measurement (splint applied with all padding removed). Results: Over a 3-fold decrease in peak contact pressure was observed after the application of 4 or 6 layers of cotton padding. This escalated to over a 6-fold decrease with 2, 4, or 6 layers of padding while the splint was positioned with the heel freely floating. Splints with 4 and 6 layers of padding decreased heel contact pressure similarly (reduced to 29% and 28% from baseline, respectively), improved from 2 layers of padding (51% decrease from baseline). The mean contact pressure with 6 layers of padding (28% from baseline) remained higher than the mean contact pressure with 0 layers of padding with the heel floating (21% from baseline). Conclusion: Lower extremity splints with 4 or 6 layers of cotton padding provided a meaningful decrease in peak posterior heel contact pressure. The greatest decrease in heel contact pressure was observed in splints with the heel floating, even with all layers of cotton padding removed. This was more optimal than all layers of cotton padding tested. This study emphasizes the critical nature of patient counseling regarding the importance of proper splint positioning with the heel floating when at rest. Neglecting to do so may put the patient at increased risk for posterior heel skin complications.https://doi.org/10.1177/2473011424S00219
spellingShingle Erik R. Nakken MD
Kempland C. Walley MD
Paul Talusan MD
David Walton MD
James Holmes MD
Contact Pressures of the Posterior Heel in Lower Extremity Splints: A Biomechanical Study
Foot & Ankle Orthopaedics
title Contact Pressures of the Posterior Heel in Lower Extremity Splints: A Biomechanical Study
title_full Contact Pressures of the Posterior Heel in Lower Extremity Splints: A Biomechanical Study
title_fullStr Contact Pressures of the Posterior Heel in Lower Extremity Splints: A Biomechanical Study
title_full_unstemmed Contact Pressures of the Posterior Heel in Lower Extremity Splints: A Biomechanical Study
title_short Contact Pressures of the Posterior Heel in Lower Extremity Splints: A Biomechanical Study
title_sort contact pressures of the posterior heel in lower extremity splints a biomechanical study
url https://doi.org/10.1177/2473011424S00219
work_keys_str_mv AT erikrnakkenmd contactpressuresoftheposteriorheelinlowerextremitysplintsabiomechanicalstudy
AT kemplandcwalleymd contactpressuresoftheposteriorheelinlowerextremitysplintsabiomechanicalstudy
AT paultalusanmd contactpressuresoftheposteriorheelinlowerextremitysplintsabiomechanicalstudy
AT davidwaltonmd contactpressuresoftheposteriorheelinlowerextremitysplintsabiomechanicalstudy
AT jamesholmesmd contactpressuresoftheposteriorheelinlowerextremitysplintsabiomechanicalstudy