Study results of the stress-strain states of the crown parts of molars restored with composite, ceramic and zirconium onlays

The relevance of the research is determined by the significant need for effective restorative treatment of caries decayed teeth. The purpose of the study is comparison of the stress-strain states in simulated models of non-homogeneous composite structural elements for typical geometric characteristi...

Full description

Saved in:
Bibliographic Details
Main Authors: Y.A. Sardykov, M.H. Kryshchuk, O.O. Fastovets, R.Y. Matvieienko
Format: Article
Language:English
Published: Dnipro State Medical University 2024-12-01
Series:Medičnì Perspektivi
Subjects:
Online Access:https://journals.uran.ua/index.php/2307-0404/article/view/319183
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841537412424007680
author Y.A. Sardykov
M.H. Kryshchuk
O.O. Fastovets
R.Y. Matvieienko
author_facet Y.A. Sardykov
M.H. Kryshchuk
O.O. Fastovets
R.Y. Matvieienko
author_sort Y.A. Sardykov
collection DOAJ
description The relevance of the research is determined by the significant need for effective restorative treatment of caries decayed teeth. The purpose of the study is comparison of the stress-strain states in simulated models of non-homogeneous composite structural elements for typical geometric characteristics of onlays made of composite, ceramic, and zirconium dioxide in the restoration of the decayed mandibular molar. Computer simulation models of biomechanical systems were obtained by digital scanning of the mandibular molar in STEP format. Control was carried out in the form of numerical characteristics and graphical visualization in the EXOCAD program. The numerical method of finite elements, information technologies and program codes of the ANSYS Workbench 12.1 system were used to solve applied problems of biomechanics. After testing the developed discrete models, they were checked for adequacy and coincidence of numerical results in areas of high voltage gradients using the tools and methods of the ANSYS 12.1 code system. The maximum displacements, gradients, and amplitudes of the Mises-equivalent stress in the structural elements of each biomechanical system were evaluated. The stress values were calculated using the method of linear scaling of the results of the numerical solution of the boundary value problems of the theory of elasticity for small deformations to correspond to the functional force load of the mandibular molar of 100 N. The estimated values of the coefficients of the strength reserve of the structural elements were calculated as the ratio of the strength limit values to the maximum calculated values of the Mises-equivalent stress, scaled by a coefficient of 10 for a force load of 100 N. It was established that the largest voltage gradients are registered at the border of the cement layer. However, the nature of force transmission, as well as stress distribution, was different for different structural materials. The maximum stress was observed in the model with a composite onlay in the local area of the surface of the force load in the cement layer. For the ceramic onlay, the maximum stress was found on the lower support surface of contact with the onlay, where its values were 1.4 times higher than on other surfaces. The analysis of the zones of maximum stress for the zirconium onlay revealed their predominant localization in the center of its occlusal surface and in the zone of change in its spatial configuration at the border with cement. The highest stress values, along with the lowest coefficients of safety margin, were found for the molar model restored with a composite onlay, which indicated the lowest endurance of this material to functional load. While the zirconium onlay provided optimal stress distribution and it was characterized by the largest safety factor, which makes this method the most acceptable for molar restoration. The obtained results should be taken into account when choosing a material for the prosthetics of lateral teeth with onlays.
format Article
id doaj-art-d36d92a4832943f2a62e24f7afcf9548
institution Kabale University
issn 2307-0404
2786-4804
language English
publishDate 2024-12-01
publisher Dnipro State Medical University
record_format Article
series Medičnì Perspektivi
spelling doaj-art-d36d92a4832943f2a62e24f7afcf95482025-01-14T08:36:59ZengDnipro State Medical UniversityMedičnì Perspektivi2307-04042786-48042024-12-01294475710.26641/2307-0404.2024.4.319183357822Study results of the stress-strain states of the crown parts of molars restored with composite, ceramic and zirconium onlaysY.A. Sardykov0https://orcid.org/0009-0006-9303-0074M.H. Kryshchuk1https://orcid.org/0000-0002-0662-9147O.O. Fastovets2https://orcid.org/0000-0002-2769-3244R.Y. Matvieienko3https://orcid.org/0000-0003-0888-3226Dnipro State Medical University, Volodymyra Vernadskoho str., 9, Dnipro, 49044National Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute”, Beresteiskyi av., 37, Kyiv, 03056Dnipro State Medical University, Volodymyra Vernadskoho str., 9, Dnipro, 49044Dnipro State Medical University, Volodymyra Vernadskoho str., 9, Dnipro, 49044The relevance of the research is determined by the significant need for effective restorative treatment of caries decayed teeth. The purpose of the study is comparison of the stress-strain states in simulated models of non-homogeneous composite structural elements for typical geometric characteristics of onlays made of composite, ceramic, and zirconium dioxide in the restoration of the decayed mandibular molar. Computer simulation models of biomechanical systems were obtained by digital scanning of the mandibular molar in STEP format. Control was carried out in the form of numerical characteristics and graphical visualization in the EXOCAD program. The numerical method of finite elements, information technologies and program codes of the ANSYS Workbench 12.1 system were used to solve applied problems of biomechanics. After testing the developed discrete models, they were checked for adequacy and coincidence of numerical results in areas of high voltage gradients using the tools and methods of the ANSYS 12.1 code system. The maximum displacements, gradients, and amplitudes of the Mises-equivalent stress in the structural elements of each biomechanical system were evaluated. The stress values were calculated using the method of linear scaling of the results of the numerical solution of the boundary value problems of the theory of elasticity for small deformations to correspond to the functional force load of the mandibular molar of 100 N. The estimated values of the coefficients of the strength reserve of the structural elements were calculated as the ratio of the strength limit values to the maximum calculated values of the Mises-equivalent stress, scaled by a coefficient of 10 for a force load of 100 N. It was established that the largest voltage gradients are registered at the border of the cement layer. However, the nature of force transmission, as well as stress distribution, was different for different structural materials. The maximum stress was observed in the model with a composite onlay in the local area of the surface of the force load in the cement layer. For the ceramic onlay, the maximum stress was found on the lower support surface of contact with the onlay, where its values were 1.4 times higher than on other surfaces. The analysis of the zones of maximum stress for the zirconium onlay revealed their predominant localization in the center of its occlusal surface and in the zone of change in its spatial configuration at the border with cement. The highest stress values, along with the lowest coefficients of safety margin, were found for the molar model restored with a composite onlay, which indicated the lowest endurance of this material to functional load. While the zirconium onlay provided optimal stress distribution and it was characterized by the largest safety factor, which makes this method the most acceptable for molar restoration. The obtained results should be taken into account when choosing a material for the prosthetics of lateral teeth with onlays.https://journals.uran.ua/index.php/2307-0404/article/view/319183molarsonlaysresin compositeceramicszirconiumfinite element methodstress-strain states
spellingShingle Y.A. Sardykov
M.H. Kryshchuk
O.O. Fastovets
R.Y. Matvieienko
Study results of the stress-strain states of the crown parts of molars restored with composite, ceramic and zirconium onlays
Medičnì Perspektivi
molars
onlays
resin composite
ceramics
zirconium
finite element method
stress-strain states
title Study results of the stress-strain states of the crown parts of molars restored with composite, ceramic and zirconium onlays
title_full Study results of the stress-strain states of the crown parts of molars restored with composite, ceramic and zirconium onlays
title_fullStr Study results of the stress-strain states of the crown parts of molars restored with composite, ceramic and zirconium onlays
title_full_unstemmed Study results of the stress-strain states of the crown parts of molars restored with composite, ceramic and zirconium onlays
title_short Study results of the stress-strain states of the crown parts of molars restored with composite, ceramic and zirconium onlays
title_sort study results of the stress strain states of the crown parts of molars restored with composite ceramic and zirconium onlays
topic molars
onlays
resin composite
ceramics
zirconium
finite element method
stress-strain states
url https://journals.uran.ua/index.php/2307-0404/article/view/319183
work_keys_str_mv AT yasardykov studyresultsofthestressstrainstatesofthecrownpartsofmolarsrestoredwithcompositeceramicandzirconiumonlays
AT mhkryshchuk studyresultsofthestressstrainstatesofthecrownpartsofmolarsrestoredwithcompositeceramicandzirconiumonlays
AT oofastovets studyresultsofthestressstrainstatesofthecrownpartsofmolarsrestoredwithcompositeceramicandzirconiumonlays
AT rymatvieienko studyresultsofthestressstrainstatesofthecrownpartsofmolarsrestoredwithcompositeceramicandzirconiumonlays