Thermal imaging control of electrical equipment of industrial enterprises

RELEVANCE. Thermal imaging control is used to monitor the technical condition of electrical equipment, as well as contacts and contact connections of switching devices, which allows to increase the efficiency of work.OBJECT. Timely detection of defects of contacts and contact connections of low-volt...

Full description

Saved in:
Bibliographic Details
Main Authors: A. N. Shpiganovich, A. A. Shpiganovich, A. R. Petrov, E. I. Gracheva
Format: Article
Language:English
Published: Kazan State Power Engineering University 2024-06-01
Series:Известия высших учебных заведений: Проблемы энергетики
Subjects:
Online Access:https://www.energyret.ru/jour/article/view/3023
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1846155369416491008
author A. N. Shpiganovich
A. A. Shpiganovich
A. R. Petrov
E. I. Gracheva
author_facet A. N. Shpiganovich
A. A. Shpiganovich
A. R. Petrov
E. I. Gracheva
author_sort A. N. Shpiganovich
collection DOAJ
description RELEVANCE. Thermal imaging control is used to monitor the technical condition of electrical equipment, as well as contacts and contact connections of switching devices, which allows to increase the efficiency of work.OBJECT. Timely detection of defects of contacts and contact connections of low-voltage switching devices to prevent emergencies.METHODS. Determination and control of technical condition of electrical equipment, contacts and contact connections of apparatuses in real time by means of indicators and thermal imaging control.RESULTS. The values of contact heating temperatures from material and type of contact connections were analysed. The criteria for estimation of the state of contacts of switching devices with the help of indicators of their state have been determined. The optimum values of loading coefficients of the circuit breaker in moulded case VA04 and contactors KMI and KTI are obtained. Emergency cases at the industrial object are shown, which prove the necessity of application of indicators and thermal imaging control as one of the tools of automation of technical condition control of low-voltage electrical equipment.CONCLUSIONS. The offered noncontact method of estimation and control of technical condition of electrical equipment, contacts and contact connections of devices in real time with the help of indicators and thermal imaging control allows both to receive data in real time mode and to increase inter-repair periods for power equipment and to increase reliability of operation of the whole system.
format Article
id doaj-art-c44489d14a5c4b4e81e1ad9aa5242b1a
institution Kabale University
issn 1998-9903
language English
publishDate 2024-06-01
publisher Kazan State Power Engineering University
record_format Article
series Известия высших учебных заведений: Проблемы энергетики
spelling doaj-art-c44489d14a5c4b4e81e1ad9aa5242b1a2024-11-26T11:39:43ZengKazan State Power Engineering UniversityИзвестия высших учебных заведений: Проблемы энергетики1998-99032024-06-01262687710.30724/1998-9903-2024-26-2-68-771002Thermal imaging control of electrical equipment of industrial enterprisesA. N. Shpiganovich0A. A. Shpiganovich1A. R. Petrov2E. I. Gracheva3Lipetsk State Technical UniversityLipetsk State Technical UniversityKazan State Power Engineering UniversityKazan State Power Engineering UniversityRELEVANCE. Thermal imaging control is used to monitor the technical condition of electrical equipment, as well as contacts and contact connections of switching devices, which allows to increase the efficiency of work.OBJECT. Timely detection of defects of contacts and contact connections of low-voltage switching devices to prevent emergencies.METHODS. Determination and control of technical condition of electrical equipment, contacts and contact connections of apparatuses in real time by means of indicators and thermal imaging control.RESULTS. The values of contact heating temperatures from material and type of contact connections were analysed. The criteria for estimation of the state of contacts of switching devices with the help of indicators of their state have been determined. The optimum values of loading coefficients of the circuit breaker in moulded case VA04 and contactors KMI and KTI are obtained. Emergency cases at the industrial object are shown, which prove the necessity of application of indicators and thermal imaging control as one of the tools of automation of technical condition control of low-voltage electrical equipment.CONCLUSIONS. The offered noncontact method of estimation and control of technical condition of electrical equipment, contacts and contact connections of devices in real time with the help of indicators and thermal imaging control allows both to receive data in real time mode and to increase inter-repair periods for power equipment and to increase reliability of operation of the whole system.https://www.energyret.ru/jour/article/view/3023electrical networkthermal imaging controlindicatorsequipment defectsswitching devicescontact connections
spellingShingle A. N. Shpiganovich
A. A. Shpiganovich
A. R. Petrov
E. I. Gracheva
Thermal imaging control of electrical equipment of industrial enterprises
Известия высших учебных заведений: Проблемы энергетики
electrical network
thermal imaging control
indicators
equipment defects
switching devices
contact connections
title Thermal imaging control of electrical equipment of industrial enterprises
title_full Thermal imaging control of electrical equipment of industrial enterprises
title_fullStr Thermal imaging control of electrical equipment of industrial enterprises
title_full_unstemmed Thermal imaging control of electrical equipment of industrial enterprises
title_short Thermal imaging control of electrical equipment of industrial enterprises
title_sort thermal imaging control of electrical equipment of industrial enterprises
topic electrical network
thermal imaging control
indicators
equipment defects
switching devices
contact connections
url https://www.energyret.ru/jour/article/view/3023
work_keys_str_mv AT anshpiganovich thermalimagingcontrolofelectricalequipmentofindustrialenterprises
AT aashpiganovich thermalimagingcontrolofelectricalequipmentofindustrialenterprises
AT arpetrov thermalimagingcontrolofelectricalequipmentofindustrialenterprises
AT eigracheva thermalimagingcontrolofelectricalequipmentofindustrialenterprises