Advanced Fault Detection and Severity Analysis of Broken Rotor Bars in Induction Motors: Comparative Classification and Feature Study Using Dimensionality Reduction Techniques
This paper presents an experimental investigation into the detection and classification of broken rotor bar (BRB) faults in a 1.1 kW squirrel cage induction motor (IM) across various load conditions and fault severities: 1.5 BRBs, 2 BRBs, 2.5 BRBs, and 3 BRBs. Motor current signature analysis (MCSA)...
Saved in:
| Main Authors: | Rahul R. Kumar, Litili O. Waisale, Jiuta L. Tamata, Andrea Tortella, Shahin H. Kia, Mauro Andriollo |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
MDPI AG
2024-12-01
|
| Series: | Machines |
| Subjects: | |
| Online Access: | https://www.mdpi.com/2075-1702/12/12/890 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Similar Items
-
A Survey of Broken Rotor Bar Fault Diagnostic Methods of Induction Motor
by: Asad Bilal, et al.
Published: (2018-12-01) -
Development of a functional system for diagnosing the presence of rotor damage in induction traction motors
by: Denys Lakusta, et al.
Published: (2024-12-01) -
Development of a Novel Squirrel-cage Doffing Robot
by: Yang Sicheng, et al.
Published: (2017-01-01) -
Grid Connection of a Squirrel-Cage Induction Generator Excited by a Partial Power Converter
by: Dominik A. Górski, et al.
Published: (2025-01-01) -
Fluid flow observer for an asynchronous electric drive of a centrifugal pump
by: O. A. Lysenko
Published: (2024-11-01)