Modelling and Extraction of Current Harmonic Components based on Instantaneous Power Theory for Shunt Active Filter under Weak Grid

The most important part in the suitable performance of the active power filter is possible by precise harmonic extraction of load current. Current harmonic extraction is possible in both time and frequency domain. However, time domain methods have higher speed and low complexity. One of the most pop...

Full description

Saved in:
Bibliographic Details
Main Authors: Farzad Sajadi, Mohammad Pichan, Adel Zakipour
Format: Article
Language:fas
Published: Semnan University 2024-04-01
Series:مجله مدل سازی در مهندسی
Subjects:
Online Access:https://modelling.semnan.ac.ir/article_8086_97f389cfbf36c92195c96e4862d7c004.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1841527704659165184
author Farzad Sajadi
Mohammad Pichan
Adel Zakipour
author_facet Farzad Sajadi
Mohammad Pichan
Adel Zakipour
author_sort Farzad Sajadi
collection DOAJ
description The most important part in the suitable performance of the active power filter is possible by precise harmonic extraction of load current. Current harmonic extraction is possible in both time and frequency domain. However, time domain methods have higher speed and low complexity. One of the most popular methods in this field is the Instantaneous Power Theory method but, the main problem is when the grid voltage is not ideal. Therefore, this paper provides a method based on the Instantaneous Power Theory that shows very good performance with the least complexity of implementation in all grid voltage states, whether asymmetry, distorted, or both at the same time. To examine the performance of the proposed method, the three -phase filtration is simulated in the MATLAB/Simulink environment under different grid voltage conditions and finally the experimental results are provided in the laboratory environment. The results verify the effectiveness of the proposed method where the THD% is decreased from 25% to 5%..
format Article
id doaj-art-bd7edf7de2354ee1b05b152afea197c3
institution Kabale University
issn 2008-4854
2783-2538
language fas
publishDate 2024-04-01
publisher Semnan University
record_format Article
series مجله مدل سازی در مهندسی
spelling doaj-art-bd7edf7de2354ee1b05b152afea197c32025-01-15T08:14:58ZfasSemnan Universityمجله مدل سازی در مهندسی2008-48542783-25382024-04-012276274410.22075/jme.2023.30169.24218086Modelling and Extraction of Current Harmonic Components based on Instantaneous Power Theory for Shunt Active Filter under Weak GridFarzad Sajadi0Mohammad Pichan1Adel Zakipour2Master of Power Electronics and Electrical Machines, Arak University of Technology, Arak, iranAssistant Professor, Faculty of Electrical Engineering, Arak University of Technology, Arak, iranAssistant Professor, Faculty of Electrical Engineering, Arak University of Technology, Arak, iranThe most important part in the suitable performance of the active power filter is possible by precise harmonic extraction of load current. Current harmonic extraction is possible in both time and frequency domain. However, time domain methods have higher speed and low complexity. One of the most popular methods in this field is the Instantaneous Power Theory method but, the main problem is when the grid voltage is not ideal. Therefore, this paper provides a method based on the Instantaneous Power Theory that shows very good performance with the least complexity of implementation in all grid voltage states, whether asymmetry, distorted, or both at the same time. To examine the performance of the proposed method, the three -phase filtration is simulated in the MATLAB/Simulink environment under different grid voltage conditions and finally the experimental results are provided in the laboratory environment. The results verify the effectiveness of the proposed method where the THD% is decreased from 25% to 5%..https://modelling.semnan.ac.ir/article_8086_97f389cfbf36c92195c96e4862d7c004.pdfshunt active power filters (sapf)positive sequence detector (psd)phase locked loopinstantaneous power theorythird order sinusoidal integrator (tossi)
spellingShingle Farzad Sajadi
Mohammad Pichan
Adel Zakipour
Modelling and Extraction of Current Harmonic Components based on Instantaneous Power Theory for Shunt Active Filter under Weak Grid
مجله مدل سازی در مهندسی
shunt active power filters (sapf)
positive sequence detector (psd)
phase locked loop
instantaneous power theory
third order sinusoidal integrator (tossi)
title Modelling and Extraction of Current Harmonic Components based on Instantaneous Power Theory for Shunt Active Filter under Weak Grid
title_full Modelling and Extraction of Current Harmonic Components based on Instantaneous Power Theory for Shunt Active Filter under Weak Grid
title_fullStr Modelling and Extraction of Current Harmonic Components based on Instantaneous Power Theory for Shunt Active Filter under Weak Grid
title_full_unstemmed Modelling and Extraction of Current Harmonic Components based on Instantaneous Power Theory for Shunt Active Filter under Weak Grid
title_short Modelling and Extraction of Current Harmonic Components based on Instantaneous Power Theory for Shunt Active Filter under Weak Grid
title_sort modelling and extraction of current harmonic components based on instantaneous power theory for shunt active filter under weak grid
topic shunt active power filters (sapf)
positive sequence detector (psd)
phase locked loop
instantaneous power theory
third order sinusoidal integrator (tossi)
url https://modelling.semnan.ac.ir/article_8086_97f389cfbf36c92195c96e4862d7c004.pdf
work_keys_str_mv AT farzadsajadi modellingandextractionofcurrentharmoniccomponentsbasedoninstantaneouspowertheoryforshuntactivefilterunderweakgrid
AT mohammadpichan modellingandextractionofcurrentharmoniccomponentsbasedoninstantaneouspowertheoryforshuntactivefilterunderweakgrid
AT adelzakipour modellingandextractionofcurrentharmoniccomponentsbasedoninstantaneouspowertheoryforshuntactivefilterunderweakgrid