Behavior of Structural Concrete Frames with Hybrid Reinforcement under Cyclic Loading
A substantial amount of work was carried out on the use of fiber-reinforced polymer (FRP) in reinforcing concrete structural elements, which demonstrated considerable inelasticity or deformity through monotonous and fatigue loads. Even so, the action of FRP bars in FRP-RC columns and frame structure...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Gruppo Italiano Frattura
2021-06-01
|
Series: | Fracture and Structural Integrity |
Subjects: | |
Online Access: | https://www.fracturae.com/index.php/fis/article/view/3058 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1841562268015263744 |
---|---|
author | Asmaa Sobhy Louay Aboul Nour Hilal Hassan Alaaeldin Elsisi |
author_facet | Asmaa Sobhy Louay Aboul Nour Hilal Hassan Alaaeldin Elsisi |
author_sort | Asmaa Sobhy |
collection | DOAJ |
description | A substantial amount of work was carried out on the use of fiber-reinforced polymer (FRP) in reinforcing concrete structural elements, which demonstrated considerable inelasticity or deformity through monotonous and fatigue loads. Even so, the action of FRP bars in FRP-RC columns and frame structures has not yet been studied during reversed cyclic loading.
In this research, reversed cyclic loading was conducted on three beam-column joint models using the finite element method with ANSYS software. The first model was for a joint designed with steel rebar for both the longitudinal reinforcement and stirrups. Glass fiber reinforced polymer (GFRP) rebar was used to reinforced the second joint model for both longitudinal reinforcement and steel stirrups, and the third joint model was designed with hybrid steel/GFRP reinforcement for the longitudinal reinforcement and steel stirrups. The performance of the three models under reversed cyclic loading, such as load vs. story drift and energy dissipation capacity, were compared. The GFRP-reinforced model displayed a predominantly elastic activity up to failure. Although its energy dissipation was weak, its performance in terms of total storey drift demand was satisfactory. |
format | Article |
id | doaj-art-b9e7be0707d1409987b99422d8c8328c |
institution | Kabale University |
issn | 1971-8993 |
language | English |
publishDate | 2021-06-01 |
publisher | Gruppo Italiano Frattura |
record_format | Article |
series | Fracture and Structural Integrity |
spelling | doaj-art-b9e7be0707d1409987b99422d8c8328c2025-01-03T01:03:16ZengGruppo Italiano FratturaFracture and Structural Integrity1971-89932021-06-011557Behavior of Structural Concrete Frames with Hybrid Reinforcement under Cyclic LoadingAsmaa Sobhy0Louay Aboul Nour1Hilal Hassan2Alaaeldin Elsisi3Zagazig University, EgyptZagazig University, Egypt Zagazig University, EgyptUniversity of Missouri, USA; on research leave from Zagazig University, Egypt A substantial amount of work was carried out on the use of fiber-reinforced polymer (FRP) in reinforcing concrete structural elements, which demonstrated considerable inelasticity or deformity through monotonous and fatigue loads. Even so, the action of FRP bars in FRP-RC columns and frame structures has not yet been studied during reversed cyclic loading. In this research, reversed cyclic loading was conducted on three beam-column joint models using the finite element method with ANSYS software. The first model was for a joint designed with steel rebar for both the longitudinal reinforcement and stirrups. Glass fiber reinforced polymer (GFRP) rebar was used to reinforced the second joint model for both longitudinal reinforcement and steel stirrups, and the third joint model was designed with hybrid steel/GFRP reinforcement for the longitudinal reinforcement and steel stirrups. The performance of the three models under reversed cyclic loading, such as load vs. story drift and energy dissipation capacity, were compared. The GFRP-reinforced model displayed a predominantly elastic activity up to failure. Although its energy dissipation was weak, its performance in terms of total storey drift demand was satisfactory.https://www.fracturae.com/index.php/fis/article/view/3058GFRPHybrid reinforcementcyclic loadingbeam-column jointframes |
spellingShingle | Asmaa Sobhy Louay Aboul Nour Hilal Hassan Alaaeldin Elsisi Behavior of Structural Concrete Frames with Hybrid Reinforcement under Cyclic Loading Fracture and Structural Integrity GFRP Hybrid reinforcement cyclic loading beam-column joint frames |
title | Behavior of Structural Concrete Frames with Hybrid Reinforcement under Cyclic Loading |
title_full | Behavior of Structural Concrete Frames with Hybrid Reinforcement under Cyclic Loading |
title_fullStr | Behavior of Structural Concrete Frames with Hybrid Reinforcement under Cyclic Loading |
title_full_unstemmed | Behavior of Structural Concrete Frames with Hybrid Reinforcement under Cyclic Loading |
title_short | Behavior of Structural Concrete Frames with Hybrid Reinforcement under Cyclic Loading |
title_sort | behavior of structural concrete frames with hybrid reinforcement under cyclic loading |
topic | GFRP Hybrid reinforcement cyclic loading beam-column joint frames |
url | https://www.fracturae.com/index.php/fis/article/view/3058 |
work_keys_str_mv | AT asmaasobhy behaviorofstructuralconcreteframeswithhybridreinforcementundercyclicloading AT louayaboulnour behaviorofstructuralconcreteframeswithhybridreinforcementundercyclicloading AT hilalhassan behaviorofstructuralconcreteframeswithhybridreinforcementundercyclicloading AT alaaeldinelsisi behaviorofstructuralconcreteframeswithhybridreinforcementundercyclicloading |