The static time of the manufactured template deviates the accuracy of implant surgery: A retrospective cohort study
[Objective:] To investigate the potential impact of surgical templates manufactured 7 days before the surgery on the accuracy of implants. The findings will serve as a valuable reference for clinical practice. [Methods:] A total of 104 patients and 164 implants were included in this study, and they...
Saved in:
| Main Authors: | , , |
|---|---|
| Format: | Article |
| Language: | zho |
| Published: |
Editorial Office of Journal of Oral and Maxillofacial Surgery
2023-06-01
|
| Series: | Kouqiang hemian waike zazhi |
| Subjects: | |
| Online Access: | https://journal06.magtech.org.cn/Jweb_joms/EN/10.3969/j.issn.1005-4979.2023.03.009 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1849225123882598400 |
|---|---|
| author | LUO Yilin LAN Dongping MAN Yi |
| author_facet | LUO Yilin LAN Dongping MAN Yi |
| author_sort | LUO Yilin |
| collection | DOAJ |
| description | [Objective:] To investigate the potential impact of surgical templates manufactured 7 days before the surgery on the accuracy of implants. The findings will serve as a valuable reference for clinical practice. [Methods:] A total of 104 patients and 164 implants were included in this study, and they were divided into two groups based on the time elapsed since template production:group 1 (≤7 days) and group 2 (>7 days). Subsequently, each group was divided into subgroups based on the different implantation sites in patients. The errors of implant placement were measured accordingly. Statistical analysis was performed using the Mann‐Whitney U test. [Results:] Group 1 included 86 implants, while group 2 included 78 implants. There was a statistically significant difference in apical deviation between the two groups (P<0.05). Additionally, significant increases in apical deviation were found in mandibular cases, distal‐extension edentulous cases, continuous edentulous cases, and cases involving anchor pin installation (P<0.05). [Conclusion:] The analysis of the data suggests that when the time elapsed since template production exceeds seven days, there is an increase in the apical deviation of the implant in cases involving mandibular, distal‐extension partial edentulism, and continuous partial edentulism. |
| format | Article |
| id | doaj-art-b9dbbc037f684d2da255bf63a6fce8a8 |
| institution | Kabale University |
| issn | 1005-4979 |
| language | zho |
| publishDate | 2023-06-01 |
| publisher | Editorial Office of Journal of Oral and Maxillofacial Surgery |
| record_format | Article |
| series | Kouqiang hemian waike zazhi |
| spelling | doaj-art-b9dbbc037f684d2da255bf63a6fce8a82025-08-25T06:10:06ZzhoEditorial Office of Journal of Oral and Maxillofacial SurgeryKouqiang hemian waike zazhi1005-49792023-06-0133318719310.3969/j.issn.1005-4979.2023.03.009The static time of the manufactured template deviates the accuracy of implant surgery: A retrospective cohort studyLUO Yilin0LAN Dongping1MAN Yi2State Key Laboratory of Oral Diseases and National Clinical Research Center for Oral Diseases, Department of Oral Implantology, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, Sichuan Province, ChinaState Key Laboratory of Oral Diseases and National Clinical Research Center for Oral Diseases, Department of Oral Implantology, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, Sichuan Province, ChinaState Key Laboratory of Oral Diseases and National Clinical Research Center for Oral Diseases, Department of Oral Implantology, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, Sichuan Province, China[Objective:] To investigate the potential impact of surgical templates manufactured 7 days before the surgery on the accuracy of implants. The findings will serve as a valuable reference for clinical practice. [Methods:] A total of 104 patients and 164 implants were included in this study, and they were divided into two groups based on the time elapsed since template production:group 1 (≤7 days) and group 2 (>7 days). Subsequently, each group was divided into subgroups based on the different implantation sites in patients. The errors of implant placement were measured accordingly. Statistical analysis was performed using the Mann‐Whitney U test. [Results:] Group 1 included 86 implants, while group 2 included 78 implants. There was a statistically significant difference in apical deviation between the two groups (P<0.05). Additionally, significant increases in apical deviation were found in mandibular cases, distal‐extension edentulous cases, continuous edentulous cases, and cases involving anchor pin installation (P<0.05). [Conclusion:] The analysis of the data suggests that when the time elapsed since template production exceeds seven days, there is an increase in the apical deviation of the implant in cases involving mandibular, distal‐extension partial edentulism, and continuous partial edentulism.https://journal06.magtech.org.cn/Jweb_joms/EN/10.3969/j.issn.1005-4979.2023.03.009implant accuracyfull‐guide template3d printing |
| spellingShingle | LUO Yilin LAN Dongping MAN Yi The static time of the manufactured template deviates the accuracy of implant surgery: A retrospective cohort study Kouqiang hemian waike zazhi implant accuracy full‐guide template 3d printing |
| title | The static time of the manufactured template deviates the accuracy of implant surgery: A retrospective cohort study |
| title_full | The static time of the manufactured template deviates the accuracy of implant surgery: A retrospective cohort study |
| title_fullStr | The static time of the manufactured template deviates the accuracy of implant surgery: A retrospective cohort study |
| title_full_unstemmed | The static time of the manufactured template deviates the accuracy of implant surgery: A retrospective cohort study |
| title_short | The static time of the manufactured template deviates the accuracy of implant surgery: A retrospective cohort study |
| title_sort | static time of the manufactured template deviates the accuracy of implant surgery a retrospective cohort study |
| topic | implant accuracy full‐guide template 3d printing |
| url | https://journal06.magtech.org.cn/Jweb_joms/EN/10.3969/j.issn.1005-4979.2023.03.009 |
| work_keys_str_mv | AT luoyilin thestatictimeofthemanufacturedtemplatedeviatestheaccuracyofimplantsurgeryaretrospectivecohortstudy AT landongping thestatictimeofthemanufacturedtemplatedeviatestheaccuracyofimplantsurgeryaretrospectivecohortstudy AT manyi thestatictimeofthemanufacturedtemplatedeviatestheaccuracyofimplantsurgeryaretrospectivecohortstudy AT luoyilin statictimeofthemanufacturedtemplatedeviatestheaccuracyofimplantsurgeryaretrospectivecohortstudy AT landongping statictimeofthemanufacturedtemplatedeviatestheaccuracyofimplantsurgeryaretrospectivecohortstudy AT manyi statictimeofthemanufacturedtemplatedeviatestheaccuracyofimplantsurgeryaretrospectivecohortstudy |