PERFORMANCE EVALUATION TECHNIQUES FOR THE NUCLEAR GRADE MAIN FEED-WATER CONTROL VALVE
A performance evaluation technology was studied for the seismic performance evaluation of nuclear safety Class II main feed-water control valve based on the ASME Code and finite element analysis platform( Femap + NX Nastran).First,we proposed an analysis model for the vertical control valve,and the...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | zho |
Published: |
Editorial Office of Journal of Mechanical Strength
2015-01-01
|
Series: | Jixie qiangdu |
Subjects: | |
Online Access: | http://www.jxqd.net.cn/thesisDetails#10.16579/j.issn.1001.9669.2015.05.023 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1841534709365997568 |
---|---|
author | LIU QingMin GAO ZhaoJie LIN Feng ZHANG QiangSheng WU Xin |
author_facet | LIU QingMin GAO ZhaoJie LIN Feng ZHANG QiangSheng WU Xin |
author_sort | LIU QingMin |
collection | DOAJ |
description | A performance evaluation technology was studied for the seismic performance evaluation of nuclear safety Class II main feed-water control valve based on the ASME Code and finite element analysis platform( Femap + NX Nastran).First,we proposed an analysis model for the vertical control valve,and the risk assessment and improvement methods for the structural characteristics of vertical control valve were studied.Then we conducted a numerical model for a control valve and compared the simulation data with those obtained from experimental test.These two showed good agreement.Finally,the seismic performance evaluation of a main feed-water control valve was performed under the combination of the seismic load and design load.The simulated relative error of inner stresses at typical site is less than 5% compared with that obtained by using empirical formula.The simulated data shows that the designed valve fulfills the design requirement for its first order frequency is bigger than 33 HZ,and the maximum stresses are within the allowable range under various load cases. |
format | Article |
id | doaj-art-b9b1d28a664a4bb5bc8b77ed5ea71a79 |
institution | Kabale University |
issn | 1001-9669 |
language | zho |
publishDate | 2015-01-01 |
publisher | Editorial Office of Journal of Mechanical Strength |
record_format | Article |
series | Jixie qiangdu |
spelling | doaj-art-b9b1d28a664a4bb5bc8b77ed5ea71a792025-01-15T02:37:51ZzhoEditorial Office of Journal of Mechanical StrengthJixie qiangdu1001-96692015-01-013791091630592774PERFORMANCE EVALUATION TECHNIQUES FOR THE NUCLEAR GRADE MAIN FEED-WATER CONTROL VALVELIU QingMinGAO ZhaoJieLIN FengZHANG QiangShengWU XinA performance evaluation technology was studied for the seismic performance evaluation of nuclear safety Class II main feed-water control valve based on the ASME Code and finite element analysis platform( Femap + NX Nastran).First,we proposed an analysis model for the vertical control valve,and the risk assessment and improvement methods for the structural characteristics of vertical control valve were studied.Then we conducted a numerical model for a control valve and compared the simulation data with those obtained from experimental test.These two showed good agreement.Finally,the seismic performance evaluation of a main feed-water control valve was performed under the combination of the seismic load and design load.The simulated relative error of inner stresses at typical site is less than 5% compared with that obtained by using empirical formula.The simulated data shows that the designed valve fulfills the design requirement for its first order frequency is bigger than 33 HZ,and the maximum stresses are within the allowable range under various load cases.http://www.jxqd.net.cn/thesisDetails#10.16579/j.issn.1001.9669.2015.05.023FEMNuclear safety Class IIFeed-water control valvePerformance evaluation |
spellingShingle | LIU QingMin GAO ZhaoJie LIN Feng ZHANG QiangSheng WU Xin PERFORMANCE EVALUATION TECHNIQUES FOR THE NUCLEAR GRADE MAIN FEED-WATER CONTROL VALVE Jixie qiangdu FEM Nuclear safety Class II Feed-water control valve Performance evaluation |
title | PERFORMANCE EVALUATION TECHNIQUES FOR THE NUCLEAR GRADE MAIN FEED-WATER CONTROL VALVE |
title_full | PERFORMANCE EVALUATION TECHNIQUES FOR THE NUCLEAR GRADE MAIN FEED-WATER CONTROL VALVE |
title_fullStr | PERFORMANCE EVALUATION TECHNIQUES FOR THE NUCLEAR GRADE MAIN FEED-WATER CONTROL VALVE |
title_full_unstemmed | PERFORMANCE EVALUATION TECHNIQUES FOR THE NUCLEAR GRADE MAIN FEED-WATER CONTROL VALVE |
title_short | PERFORMANCE EVALUATION TECHNIQUES FOR THE NUCLEAR GRADE MAIN FEED-WATER CONTROL VALVE |
title_sort | performance evaluation techniques for the nuclear grade main feed water control valve |
topic | FEM Nuclear safety Class II Feed-water control valve Performance evaluation |
url | http://www.jxqd.net.cn/thesisDetails#10.16579/j.issn.1001.9669.2015.05.023 |
work_keys_str_mv | AT liuqingmin performanceevaluationtechniquesforthenucleargrademainfeedwatercontrolvalve AT gaozhaojie performanceevaluationtechniquesforthenucleargrademainfeedwatercontrolvalve AT linfeng performanceevaluationtechniquesforthenucleargrademainfeedwatercontrolvalve AT zhangqiangsheng performanceevaluationtechniquesforthenucleargrademainfeedwatercontrolvalve AT wuxin performanceevaluationtechniquesforthenucleargrademainfeedwatercontrolvalve |