Comparison of the dimensional accuracy of two polyvinyl siloxane putty-wash techniques and digital impressions for single implants adjacent to tooth crown preparations
Objective: This study compared the dimensional accuracy of two polyvinyl siloxane putty-wash impression techniques with the digital impression method for single implants adjacent to tooth crown preparations.Methods: Impressions were taken from a dental arch containing a full-metal preparation on the...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Mashhad University of Medical Sciences
2024-12-01
|
Series: | Journal of Dental Materials and Techniques |
Subjects: | |
Online Access: | https://jdmt.mums.ac.ir/article_25380_4ada3379a0c44d0548515baec52f21ce.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
_version_ | 1841527925139046400 |
---|---|
author | Hamidreza Rajati Haghi Hossein Dashti Saeid Sabzevari Amineh Khoshbakhti Alireza Dankoub |
author_facet | Hamidreza Rajati Haghi Hossein Dashti Saeid Sabzevari Amineh Khoshbakhti Alireza Dankoub |
author_sort | Hamidreza Rajati Haghi |
collection | DOAJ |
description | Objective: This study compared the dimensional accuracy of two polyvinyl siloxane putty-wash impression techniques with the digital impression method for single implants adjacent to tooth crown preparations.Methods: Impressions were taken from a dental arch containing a full-metal preparation on the first molar adjacent to a Straumann tissue-level implant at the second premolar site. A laboratory scanner generated a standard tessellation language (STL) file as the reference for comparisons. Three methods were tested, each performed 10 times: (1) one-step putty-wash technique, (2) two-step putty-wash technique, and (3) digital impressions. Dimensional accuracy was assessed by measuring overall die dimensions, die height, die width, and the tooth-implant distance, using Geomagic Wrap software. Statistical analyses included one-way ANOVA and the Kruskal-Wallis test, with significance at P < 0.05.Results: No significant differences were found among the methods for the die height (P = 0.130), die width (P = 0.180), and tooth-implant distance (P = 0.486). However, the digital impression method showed significantly greater overall dimensional accuracy than the one-step putty-wash technique (P = 0.004). The two-step putty-wash method showed no significant difference with the one-step method or digital impressions concerning the overall die accuracy (P > 0.05).Conclusions: Digital impressions demonstrated significantly higher overall dimensional accuracy than the one-step putty-wash technique. Die height, die width, and tooth-implant distance were comparable across methods. Digital impressions are recommended for optimal accuracy when taking impressions from single implants adjacent to tooth crown preparations. The two-step putty-wash method offers a reliable alternative when digital tools are unavailable. |
format | Article |
id | doaj-art-b99271cc15de4454b7384a49b10a47e2 |
institution | Kabale University |
issn | 2322-4150 2252-0317 |
language | English |
publishDate | 2024-12-01 |
publisher | Mashhad University of Medical Sciences |
record_format | Article |
series | Journal of Dental Materials and Techniques |
spelling | doaj-art-b99271cc15de4454b7384a49b10a47e22025-01-15T05:33:18ZengMashhad University of Medical SciencesJournal of Dental Materials and Techniques2322-41502252-03172024-12-0113420120610.22038/jdmt.2024.82529.171425380Comparison of the dimensional accuracy of two polyvinyl siloxane putty-wash techniques and digital impressions for single implants adjacent to tooth crown preparationsHamidreza Rajati Haghi0Hossein Dashti1Saeid Sabzevari2Amineh Khoshbakhti3Alireza Dankoub4Department of Prosthodontics, School of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran.Department of Prosthodontics, School of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran.Department of Prosthodontics, School of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran.Student Research Committee, Mashhad University of Medical Sciences, Mashhad, IranDepartment of Prosthodontics, School of Dentistry, Mashhad University of Medical Sciences, Mashhad, IranObjective: This study compared the dimensional accuracy of two polyvinyl siloxane putty-wash impression techniques with the digital impression method for single implants adjacent to tooth crown preparations.Methods: Impressions were taken from a dental arch containing a full-metal preparation on the first molar adjacent to a Straumann tissue-level implant at the second premolar site. A laboratory scanner generated a standard tessellation language (STL) file as the reference for comparisons. Three methods were tested, each performed 10 times: (1) one-step putty-wash technique, (2) two-step putty-wash technique, and (3) digital impressions. Dimensional accuracy was assessed by measuring overall die dimensions, die height, die width, and the tooth-implant distance, using Geomagic Wrap software. Statistical analyses included one-way ANOVA and the Kruskal-Wallis test, with significance at P < 0.05.Results: No significant differences were found among the methods for the die height (P = 0.130), die width (P = 0.180), and tooth-implant distance (P = 0.486). However, the digital impression method showed significantly greater overall dimensional accuracy than the one-step putty-wash technique (P = 0.004). The two-step putty-wash method showed no significant difference with the one-step method or digital impressions concerning the overall die accuracy (P > 0.05).Conclusions: Digital impressions demonstrated significantly higher overall dimensional accuracy than the one-step putty-wash technique. Die height, die width, and tooth-implant distance were comparable across methods. Digital impressions are recommended for optimal accuracy when taking impressions from single implants adjacent to tooth crown preparations. The two-step putty-wash method offers a reliable alternative when digital tools are unavailable.https://jdmt.mums.ac.ir/article_25380_4ada3379a0c44d0548515baec52f21ce.pdfdental impression techniquedental impression materialvinyl polysiloxanedental prosthesisdental implantsdimensional measurement accuracy |
spellingShingle | Hamidreza Rajati Haghi Hossein Dashti Saeid Sabzevari Amineh Khoshbakhti Alireza Dankoub Comparison of the dimensional accuracy of two polyvinyl siloxane putty-wash techniques and digital impressions for single implants adjacent to tooth crown preparations Journal of Dental Materials and Techniques dental impression technique dental impression material vinyl polysiloxane dental prosthesis dental implants dimensional measurement accuracy |
title | Comparison of the dimensional accuracy of two polyvinyl siloxane putty-wash techniques and digital impressions for single implants adjacent to tooth crown preparations |
title_full | Comparison of the dimensional accuracy of two polyvinyl siloxane putty-wash techniques and digital impressions for single implants adjacent to tooth crown preparations |
title_fullStr | Comparison of the dimensional accuracy of two polyvinyl siloxane putty-wash techniques and digital impressions for single implants adjacent to tooth crown preparations |
title_full_unstemmed | Comparison of the dimensional accuracy of two polyvinyl siloxane putty-wash techniques and digital impressions for single implants adjacent to tooth crown preparations |
title_short | Comparison of the dimensional accuracy of two polyvinyl siloxane putty-wash techniques and digital impressions for single implants adjacent to tooth crown preparations |
title_sort | comparison of the dimensional accuracy of two polyvinyl siloxane putty wash techniques and digital impressions for single implants adjacent to tooth crown preparations |
topic | dental impression technique dental impression material vinyl polysiloxane dental prosthesis dental implants dimensional measurement accuracy |
url | https://jdmt.mums.ac.ir/article_25380_4ada3379a0c44d0548515baec52f21ce.pdf |
work_keys_str_mv | AT hamidrezarajatihaghi comparisonofthedimensionalaccuracyoftwopolyvinylsiloxaneputtywashtechniquesanddigitalimpressionsforsingleimplantsadjacenttotoothcrownpreparations AT hosseindashti comparisonofthedimensionalaccuracyoftwopolyvinylsiloxaneputtywashtechniquesanddigitalimpressionsforsingleimplantsadjacenttotoothcrownpreparations AT saeidsabzevari comparisonofthedimensionalaccuracyoftwopolyvinylsiloxaneputtywashtechniquesanddigitalimpressionsforsingleimplantsadjacenttotoothcrownpreparations AT aminehkhoshbakhti comparisonofthedimensionalaccuracyoftwopolyvinylsiloxaneputtywashtechniquesanddigitalimpressionsforsingleimplantsadjacenttotoothcrownpreparations AT alirezadankoub comparisonofthedimensionalaccuracyoftwopolyvinylsiloxaneputtywashtechniquesanddigitalimpressionsforsingleimplantsadjacenttotoothcrownpreparations |