Dimensional stability of two impression materials after a 6-month storage period

Objective: Oral rehabilitation success is enhanced by an accurate and reproducible final impression. The purpose of this study is to evaluate the dimensional changes of a polyether and addition silicone subjected to disinfection and/or sterilization after a long storage period. Material and methods:...

Full description

Saved in:
Bibliographic Details
Main Authors: Francisco Martins, Patrícia Branco, José Reis, Ignacio Barbero Navarro, Paulo Maurício
Format: Article
Language:English
Published: Medical Journals Sweden 2017-01-01
Series:Acta Biomaterialia Odontologica Scandinavica
Subjects:
Online Access:http://dx.doi.org/10.1080/23337931.2017.1401933
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1846146988365578240
author Francisco Martins
Patrícia Branco
José Reis
Ignacio Barbero Navarro
Paulo Maurício
author_facet Francisco Martins
Patrícia Branco
José Reis
Ignacio Barbero Navarro
Paulo Maurício
author_sort Francisco Martins
collection DOAJ
description Objective: Oral rehabilitation success is enhanced by an accurate and reproducible final impression. The purpose of this study is to evaluate the dimensional changes of a polyether and addition silicone subjected to disinfection and/or sterilization after a long storage period. Material and methods: Ninety samples were obtained from polyether ImpregumTM PentaTM (3M ESPETM, Seefeld, Germany) and 90 of addition silicone ImprintTM 4 PentaTM Putty (3M ESPETM, Seefeld, Germany) according to ISO 4823:2000. The samples of each material were split to form three groups with 30 samples each: a control group, a hypochlorite group (disinfection) and an autoclave group (sterilization). Samples were stored in the Portuguese Institute for Quality for six months at 23 °C. Samples were measured by laser interferometry, according to the Michelson technique before calculating dimensional stability according ISO 4823:2000. A statistical analysis via a three-way mixed ANOVA was performed. Results: Significant shrinkage of ImpregumTM PentaTM was 0.77 ± 0.17% in the control group, 0.42 ± 0.19% in the hypochlorite group and 0.52 ± 0.28% in the autoclave group. For ImprintTM 4 PentaTM Putty, the control group had a shrinkage of 0.42 ± 0.12%, the hypochlorite group 0.36 ± 0.09% and the autoclave group 0.59 ± 0.13%. Conclusions: The long-term storage of samples subjected to disinfection with 5.25% hypochlorite or autoclave sterilization can be used in a clinical setting as the dimensional changes are below the maximum permitted by the ISO 4823:2000, since there are no clinically significant changes in the dimension of the samples during the storage period.
format Article
id doaj-art-b7f0cd7b78d34cdd97d0e10e89b226d6
institution Kabale University
issn 2333-7931
language English
publishDate 2017-01-01
publisher Medical Journals Sweden
record_format Article
series Acta Biomaterialia Odontologica Scandinavica
spelling doaj-art-b7f0cd7b78d34cdd97d0e10e89b226d62024-12-02T00:15:28ZengMedical Journals SwedenActa Biomaterialia Odontologica Scandinavica2333-79312017-01-0131849110.1080/23337931.2017.14019331401933Dimensional stability of two impression materials after a 6-month storage periodFrancisco Martins0Patrícia Branco1José Reis2Ignacio Barbero Navarro3Paulo Maurício4Instituto Superior de Ciências da Saúde Egas MonizInstituto Superior de Ciências da Saúde Egas MonizInstituto Superior de Ciências da Saúde Egas MonizUniversidad de SevillaInstituto Superior de Ciências da Saúde Egas MonizObjective: Oral rehabilitation success is enhanced by an accurate and reproducible final impression. The purpose of this study is to evaluate the dimensional changes of a polyether and addition silicone subjected to disinfection and/or sterilization after a long storage period. Material and methods: Ninety samples were obtained from polyether ImpregumTM PentaTM (3M ESPETM, Seefeld, Germany) and 90 of addition silicone ImprintTM 4 PentaTM Putty (3M ESPETM, Seefeld, Germany) according to ISO 4823:2000. The samples of each material were split to form three groups with 30 samples each: a control group, a hypochlorite group (disinfection) and an autoclave group (sterilization). Samples were stored in the Portuguese Institute for Quality for six months at 23 °C. Samples were measured by laser interferometry, according to the Michelson technique before calculating dimensional stability according ISO 4823:2000. A statistical analysis via a three-way mixed ANOVA was performed. Results: Significant shrinkage of ImpregumTM PentaTM was 0.77 ± 0.17% in the control group, 0.42 ± 0.19% in the hypochlorite group and 0.52 ± 0.28% in the autoclave group. For ImprintTM 4 PentaTM Putty, the control group had a shrinkage of 0.42 ± 0.12%, the hypochlorite group 0.36 ± 0.09% and the autoclave group 0.59 ± 0.13%. Conclusions: The long-term storage of samples subjected to disinfection with 5.25% hypochlorite or autoclave sterilization can be used in a clinical setting as the dimensional changes are below the maximum permitted by the ISO 4823:2000, since there are no clinically significant changes in the dimension of the samples during the storage period.http://dx.doi.org/10.1080/23337931.2017.1401933Elastomerssterilizationlaser interferometry
spellingShingle Francisco Martins
Patrícia Branco
José Reis
Ignacio Barbero Navarro
Paulo Maurício
Dimensional stability of two impression materials after a 6-month storage period
Acta Biomaterialia Odontologica Scandinavica
Elastomers
sterilization
laser interferometry
title Dimensional stability of two impression materials after a 6-month storage period
title_full Dimensional stability of two impression materials after a 6-month storage period
title_fullStr Dimensional stability of two impression materials after a 6-month storage period
title_full_unstemmed Dimensional stability of two impression materials after a 6-month storage period
title_short Dimensional stability of two impression materials after a 6-month storage period
title_sort dimensional stability of two impression materials after a 6 month storage period
topic Elastomers
sterilization
laser interferometry
url http://dx.doi.org/10.1080/23337931.2017.1401933
work_keys_str_mv AT franciscomartins dimensionalstabilityoftwoimpressionmaterialsaftera6monthstorageperiod
AT patriciabranco dimensionalstabilityoftwoimpressionmaterialsaftera6monthstorageperiod
AT josereis dimensionalstabilityoftwoimpressionmaterialsaftera6monthstorageperiod
AT ignaciobarberonavarro dimensionalstabilityoftwoimpressionmaterialsaftera6monthstorageperiod
AT paulomauricio dimensionalstabilityoftwoimpressionmaterialsaftera6monthstorageperiod