A type II endoleak from an accessory renal artery treated with laser assisted, transgraft coil embolization: A case report

The main complications of coverage accessory renal artery (ARA) are renal infarction and potentially renal function impairment and type II endoleak if firm apposition to the aortic wall is not achieved. We describe the management of an ARA type II endoleak treated by laser-assisted, transgraft coil...

Full description

Saved in:
Bibliographic Details
Main Authors: Marco Panagrosso, MD, Katarina Björse, MD, Timothy Resch, MD, PhD
Format: Article
Language:English
Published: Elsevier 2024-12-01
Series:Journal of Vascular Surgery Cases and Innovative Techniques
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2468428724001825
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1846148835306373120
author Marco Panagrosso, MD
Katarina Björse, MD
Timothy Resch, MD, PhD
author_facet Marco Panagrosso, MD
Katarina Björse, MD
Timothy Resch, MD, PhD
author_sort Marco Panagrosso, MD
collection DOAJ
description The main complications of coverage accessory renal artery (ARA) are renal infarction and potentially renal function impairment and type II endoleak if firm apposition to the aortic wall is not achieved. We describe the management of an ARA type II endoleak treated by laser-assisted, transgraft coil embolization (LATE). A 76-year-old patient underwent a computed tomography scan 4 years after endovascular aneurysm repair. The computed tomography scan showed an increase of sac diameter with type II endoleak originating from the left ARA as an effect of aortic neck dilatation. ARA embolization was performed successfully via fusion-guided laser in situ fenestration and standard coil placement.
format Article
id doaj-art-b1f4ff67af1a4c8c9bc3ba5ca8940adc
institution Kabale University
issn 2468-4287
language English
publishDate 2024-12-01
publisher Elsevier
record_format Article
series Journal of Vascular Surgery Cases and Innovative Techniques
spelling doaj-art-b1f4ff67af1a4c8c9bc3ba5ca8940adc2024-11-30T07:13:29ZengElsevierJournal of Vascular Surgery Cases and Innovative Techniques2468-42872024-12-01106101598A type II endoleak from an accessory renal artery treated with laser assisted, transgraft coil embolization: A case reportMarco Panagrosso, MD0Katarina Björse, MD1Timothy Resch, MD, PhD2Division of Vascular Surgery, Department of Cardiovascular Sciences, S. Anna and S. Sebastiano Hospital, Caserta, Italy; Correspondence: Marco Panagrosso, MD, Division of Vascular Surgery, Department of Cardiovascular Sciences, S. Anna and S. Sebastiano Hospital, via Palasciano, 81100 Caserta, ItalyDepartment of Vascular Surgery, Rigshospitalet, Copenhagen, DenmarkDepartment of Vascular Surgery, Rigshospitalet, Copenhagen, Denmark; Department of Clinical Medicine, University of Copenhagen, Copenhagen, DenmarkThe main complications of coverage accessory renal artery (ARA) are renal infarction and potentially renal function impairment and type II endoleak if firm apposition to the aortic wall is not achieved. We describe the management of an ARA type II endoleak treated by laser-assisted, transgraft coil embolization (LATE). A 76-year-old patient underwent a computed tomography scan 4 years after endovascular aneurysm repair. The computed tomography scan showed an increase of sac diameter with type II endoleak originating from the left ARA as an effect of aortic neck dilatation. ARA embolization was performed successfully via fusion-guided laser in situ fenestration and standard coil placement.http://www.sciencedirect.com/science/article/pii/S2468428724001825LaserEndovascular aneurysm repairAccessory renal arteryEndoleakEmbolizationCoils
spellingShingle Marco Panagrosso, MD
Katarina Björse, MD
Timothy Resch, MD, PhD
A type II endoleak from an accessory renal artery treated with laser assisted, transgraft coil embolization: A case report
Journal of Vascular Surgery Cases and Innovative Techniques
Laser
Endovascular aneurysm repair
Accessory renal artery
Endoleak
Embolization
Coils
title A type II endoleak from an accessory renal artery treated with laser assisted, transgraft coil embolization: A case report
title_full A type II endoleak from an accessory renal artery treated with laser assisted, transgraft coil embolization: A case report
title_fullStr A type II endoleak from an accessory renal artery treated with laser assisted, transgraft coil embolization: A case report
title_full_unstemmed A type II endoleak from an accessory renal artery treated with laser assisted, transgraft coil embolization: A case report
title_short A type II endoleak from an accessory renal artery treated with laser assisted, transgraft coil embolization: A case report
title_sort type ii endoleak from an accessory renal artery treated with laser assisted transgraft coil embolization a case report
topic Laser
Endovascular aneurysm repair
Accessory renal artery
Endoleak
Embolization
Coils
url http://www.sciencedirect.com/science/article/pii/S2468428724001825
work_keys_str_mv AT marcopanagrossomd atypeiiendoleakfromanaccessoryrenalarterytreatedwithlaserassistedtransgraftcoilembolizationacasereport
AT katarinabjorsemd atypeiiendoleakfromanaccessoryrenalarterytreatedwithlaserassistedtransgraftcoilembolizationacasereport
AT timothyreschmdphd atypeiiendoleakfromanaccessoryrenalarterytreatedwithlaserassistedtransgraftcoilembolizationacasereport
AT marcopanagrossomd typeiiendoleakfromanaccessoryrenalarterytreatedwithlaserassistedtransgraftcoilembolizationacasereport
AT katarinabjorsemd typeiiendoleakfromanaccessoryrenalarterytreatedwithlaserassistedtransgraftcoilembolizationacasereport
AT timothyreschmdphd typeiiendoleakfromanaccessoryrenalarterytreatedwithlaserassistedtransgraftcoilembolizationacasereport