A complication of micropuncture catheter fracture during StarClose re-puncture and review of the literature
Permanent vascular closure systems are commonly used for achieving hemostasis after transfemoral percutaneous procedures. However, there exists conflicting data regarding the safety of re-puncturing these devices during subsequent procedures. Because percutaneous procedures have become more prevalen...
Saved in:
| Main Authors: | , , , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Elsevier
2025-10-01
|
| Series: | Journal of Vascular Surgery Cases and Innovative Techniques |
| Subjects: | |
| Online Access: | http://www.sciencedirect.com/science/article/pii/S2468428725001509 |
| Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
| _version_ | 1849320191175950336 |
|---|---|
| author | Ravi Masson, MD Charles Sineri, DO Edwin Cheung, MD John Reilly, MD David Landau, MD On Chen, MD |
| author_facet | Ravi Masson, MD Charles Sineri, DO Edwin Cheung, MD John Reilly, MD David Landau, MD On Chen, MD |
| author_sort | Ravi Masson, MD |
| collection | DOAJ |
| description | Permanent vascular closure systems are commonly used for achieving hemostasis after transfemoral percutaneous procedures. However, there exists conflicting data regarding the safety of re-puncturing these devices during subsequent procedures. Because percutaneous procedures have become more prevalent, so have the use of vascular closure devices, emphasizing the need to understand their limitations. The following case report describes a situation where a micropuncture catheter fractured within a closure device during inadvertent repeat device access and the challenges encountered with its retrieval. |
| format | Article |
| id | doaj-art-b1497e2b5cfa4c57b37c1cfd6e8d9230 |
| institution | Kabale University |
| issn | 2468-4287 |
| language | English |
| publishDate | 2025-10-01 |
| publisher | Elsevier |
| record_format | Article |
| series | Journal of Vascular Surgery Cases and Innovative Techniques |
| spelling | doaj-art-b1497e2b5cfa4c57b37c1cfd6e8d92302025-08-20T03:50:11ZengElsevierJournal of Vascular Surgery Cases and Innovative Techniques2468-42872025-10-0111510186810.1016/j.jvscit.2025.101868A complication of micropuncture catheter fracture during StarClose re-puncture and review of the literatureRavi Masson, MD0Charles Sineri, DO1Edwin Cheung, MD2John Reilly, MD3David Landau, MD4On Chen, MD5Division of Cardiology, Department of Medicine, Stony Brook University Hospital, Stony Brook, NY; Correspondence: Ravi Masson, MD, Stony Brook University Hospital, Department of Cardiology, 101 Nicolls Road, Stony Brook, NY 11794Division of Cardiology, Department of Medicine, Stony Brook University Hospital, Stony Brook, NYDivision of Vascular and Endovascular Surgery, Department of Surgery, Stony Brook University Hospital, Stony Brook, NYDivision of Cardiology, Department of Medicine, Stony Brook University Hospital, Stony Brook, NYDivision of Vascular and Endovascular Surgery, Department of Surgery, Stony Brook University Hospital, Stony Brook, NYDivision of Cardiology, Department of Medicine, Stony Brook University Hospital, Stony Brook, NYPermanent vascular closure systems are commonly used for achieving hemostasis after transfemoral percutaneous procedures. However, there exists conflicting data regarding the safety of re-puncturing these devices during subsequent procedures. Because percutaneous procedures have become more prevalent, so have the use of vascular closure devices, emphasizing the need to understand their limitations. The following case report describes a situation where a micropuncture catheter fractured within a closure device during inadvertent repeat device access and the challenges encountered with its retrieval.http://www.sciencedirect.com/science/article/pii/S2468428725001509Vascular accessComplicationsFemoral arteryClosure deviceCase report |
| spellingShingle | Ravi Masson, MD Charles Sineri, DO Edwin Cheung, MD John Reilly, MD David Landau, MD On Chen, MD A complication of micropuncture catheter fracture during StarClose re-puncture and review of the literature Journal of Vascular Surgery Cases and Innovative Techniques Vascular access Complications Femoral artery Closure device Case report |
| title | A complication of micropuncture catheter fracture during StarClose re-puncture and review of the literature |
| title_full | A complication of micropuncture catheter fracture during StarClose re-puncture and review of the literature |
| title_fullStr | A complication of micropuncture catheter fracture during StarClose re-puncture and review of the literature |
| title_full_unstemmed | A complication of micropuncture catheter fracture during StarClose re-puncture and review of the literature |
| title_short | A complication of micropuncture catheter fracture during StarClose re-puncture and review of the literature |
| title_sort | complication of micropuncture catheter fracture during starclose re puncture and review of the literature |
| topic | Vascular access Complications Femoral artery Closure device Case report |
| url | http://www.sciencedirect.com/science/article/pii/S2468428725001509 |
| work_keys_str_mv | AT ravimassonmd acomplicationofmicropuncturecatheterfractureduringstarcloserepunctureandreviewoftheliterature AT charlessinerido acomplicationofmicropuncturecatheterfractureduringstarcloserepunctureandreviewoftheliterature AT edwincheungmd acomplicationofmicropuncturecatheterfractureduringstarcloserepunctureandreviewoftheliterature AT johnreillymd acomplicationofmicropuncturecatheterfractureduringstarcloserepunctureandreviewoftheliterature AT davidlandaumd acomplicationofmicropuncturecatheterfractureduringstarcloserepunctureandreviewoftheliterature AT onchenmd acomplicationofmicropuncturecatheterfractureduringstarcloserepunctureandreviewoftheliterature AT ravimassonmd complicationofmicropuncturecatheterfractureduringstarcloserepunctureandreviewoftheliterature AT charlessinerido complicationofmicropuncturecatheterfractureduringstarcloserepunctureandreviewoftheliterature AT edwincheungmd complicationofmicropuncturecatheterfractureduringstarcloserepunctureandreviewoftheliterature AT johnreillymd complicationofmicropuncturecatheterfractureduringstarcloserepunctureandreviewoftheliterature AT davidlandaumd complicationofmicropuncturecatheterfractureduringstarcloserepunctureandreviewoftheliterature AT onchenmd complicationofmicropuncturecatheterfractureduringstarcloserepunctureandreviewoftheliterature |