A wearable circulator‐like circularly polarised antenna for full‐duplex wireless body area network applications

Abstract A circulator‐like high gain, unidirectional, dual circularly polarised (DCP) wearable antenna with a low specific absorption rate of 0.088 W/kg for 5.8 GHz industrial, scientific, and medical (ISM) band (5.725−5.875 GHz) full‐duplex wireless body area network (WBAN) applications is proposed...

Full description

Saved in:
Bibliographic Details
Main Authors: Ajeet Thakur, Ashwani Sharma, Ignacio J. Garcia Zuazola
Format: Article
Language:English
Published: Wiley 2024-11-01
Series:IET Microwaves, Antennas & Propagation
Subjects:
Online Access:https://doi.org/10.1049/mia2.12507
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1846155362724478976
author Ajeet Thakur
Ashwani Sharma
Ignacio J. Garcia Zuazola
author_facet Ajeet Thakur
Ashwani Sharma
Ignacio J. Garcia Zuazola
author_sort Ajeet Thakur
collection DOAJ
description Abstract A circulator‐like high gain, unidirectional, dual circularly polarised (DCP) wearable antenna with a low specific absorption rate of 0.088 W/kg for 5.8 GHz industrial, scientific, and medical (ISM) band (5.725−5.875 GHz) full‐duplex wireless body area network (WBAN) applications is proposed. The DCP full‐duplexing is achieved by a closed‐loop feedback structure between its orthogonal‐ports with enhanced axial ratio (AR) bandwidth and good impedance matching. The antenna is backed with a 7×7 electromagnetic bandgap array that allows for improved directionality, AR and isolation between the ports. The cross‐polarisation level above 17 dB is attained in the broadside direction, in both the E‐plane and the H‐plane, indicating good polarisation discrimination. Since the total power at each respective port is maintained and not halved (−3 dB) with the measured port isolation of ˜28 dB in real scenarios (with the potential evidence of ˜34 dB) within the ISM band, that leads to a circulator‐like antenna, meaning that a typically cascaded circulator/duplexer can be relieved and leave to the digital processing any self‐interference challenge of full duplex systems through digital cancelation techniques, which alleviates the overall costs of RF hardware and eases integration. Even though dual linear polarization as well as DCP can be supported, the closed‐loop feedback structure uses a port as Tx (RHCP) and the other one as Rx (LHCP) simultaneously with enhanced AR bandwidth. Without this structure, it would require a circulator/duplexer for DCP full‐duplex operation and the associated added insertion losses and/or 12 power (if duplexers) for operation, together with a polarisation misalignment problem that is undesired in wearable WBAN applications.
format Article
id doaj-art-afb84b73b60b4f058e00373a6d79b43b
institution Kabale University
issn 1751-8725
1751-8733
language English
publishDate 2024-11-01
publisher Wiley
record_format Article
series IET Microwaves, Antennas & Propagation
spelling doaj-art-afb84b73b60b4f058e00373a6d79b43b2024-11-26T12:12:12ZengWileyIET Microwaves, Antennas & Propagation1751-87251751-87332024-11-01181183884810.1049/mia2.12507A wearable circulator‐like circularly polarised antenna for full‐duplex wireless body area network applicationsAjeet Thakur0Ashwani Sharma1Ignacio J. Garcia Zuazola2Electrical Engineering Department Indian Institute of Technology Ropar Punjab IndiaElectrical Engineering Department Indian Institute of Technology Ropar Punjab IndiaSchool of Computing and Digital Media London Metropolitan University London UKAbstract A circulator‐like high gain, unidirectional, dual circularly polarised (DCP) wearable antenna with a low specific absorption rate of 0.088 W/kg for 5.8 GHz industrial, scientific, and medical (ISM) band (5.725−5.875 GHz) full‐duplex wireless body area network (WBAN) applications is proposed. The DCP full‐duplexing is achieved by a closed‐loop feedback structure between its orthogonal‐ports with enhanced axial ratio (AR) bandwidth and good impedance matching. The antenna is backed with a 7×7 electromagnetic bandgap array that allows for improved directionality, AR and isolation between the ports. The cross‐polarisation level above 17 dB is attained in the broadside direction, in both the E‐plane and the H‐plane, indicating good polarisation discrimination. Since the total power at each respective port is maintained and not halved (−3 dB) with the measured port isolation of ˜28 dB in real scenarios (with the potential evidence of ˜34 dB) within the ISM band, that leads to a circulator‐like antenna, meaning that a typically cascaded circulator/duplexer can be relieved and leave to the digital processing any self‐interference challenge of full duplex systems through digital cancelation techniques, which alleviates the overall costs of RF hardware and eases integration. Even though dual linear polarization as well as DCP can be supported, the closed‐loop feedback structure uses a port as Tx (RHCP) and the other one as Rx (LHCP) simultaneously with enhanced AR bandwidth. Without this structure, it would require a circulator/duplexer for DCP full‐duplex operation and the associated added insertion losses and/or 12 power (if duplexers) for operation, together with a polarisation misalignment problem that is undesired in wearable WBAN applications.https://doi.org/10.1049/mia2.12507antenna testingantennasmicrowave antennas
spellingShingle Ajeet Thakur
Ashwani Sharma
Ignacio J. Garcia Zuazola
A wearable circulator‐like circularly polarised antenna for full‐duplex wireless body area network applications
IET Microwaves, Antennas & Propagation
antenna testing
antennas
microwave antennas
title A wearable circulator‐like circularly polarised antenna for full‐duplex wireless body area network applications
title_full A wearable circulator‐like circularly polarised antenna for full‐duplex wireless body area network applications
title_fullStr A wearable circulator‐like circularly polarised antenna for full‐duplex wireless body area network applications
title_full_unstemmed A wearable circulator‐like circularly polarised antenna for full‐duplex wireless body area network applications
title_short A wearable circulator‐like circularly polarised antenna for full‐duplex wireless body area network applications
title_sort wearable circulator like circularly polarised antenna for full duplex wireless body area network applications
topic antenna testing
antennas
microwave antennas
url https://doi.org/10.1049/mia2.12507
work_keys_str_mv AT ajeetthakur awearablecirculatorlikecircularlypolarisedantennaforfullduplexwirelessbodyareanetworkapplications
AT ashwanisharma awearablecirculatorlikecircularlypolarisedantennaforfullduplexwirelessbodyareanetworkapplications
AT ignaciojgarciazuazola awearablecirculatorlikecircularlypolarisedantennaforfullduplexwirelessbodyareanetworkapplications
AT ajeetthakur wearablecirculatorlikecircularlypolarisedantennaforfullduplexwirelessbodyareanetworkapplications
AT ashwanisharma wearablecirculatorlikecircularlypolarisedantennaforfullduplexwirelessbodyareanetworkapplications
AT ignaciojgarciazuazola wearablecirculatorlikecircularlypolarisedantennaforfullduplexwirelessbodyareanetworkapplications